Catalog excerpts
Temperature Sensor FL-TF 80 S/M Ifor use in mixers, aggregate silos and cement weighing systems APPLICATION in the concrete and precast industry. For all common mixer types, aggregate silos and cement weighing systems to monitor the additive and concrete temperature. CHARACTERISTICAL FEATURES high wear resistant sensor tip enables extended life time even with abrasive installations -> compact construction -> easy installation -> measure signal transmittance through reliable two wire technology linear output signal Franz Ludwig GmbH www.fludwig.com
Open the catalog to page 1INSTALLATION POSITION IN MIXER Mixer wall insert approx. 2 mm deepe r Mixer bottom INSTALLATION POSITION IN CONTAINER Please install the temperature probe the way that even the temperature is grasped when dosing small quanties and the probe is self cleaning through the material flow. PROBE FIXING ON MIXER WALL / IN CONTAINER high wear resistant Measure surface 15 mm Connec tion cable flexible, shielded Mixer / Container wall probable lining IMPORTANT If the whole is too big, there is a danger