Variable Frequency Drive DRIVE-TECH
8Pages

{{requestButtons}}

Catalog excerpts

Variable Frequency Drive DRIVE-TECH - 1

Variable Frequency Drive

Open the catalog to page 1
Variable Frequency Drive DRIVE-TECH - 2

APPLICATIONS BUILDING SERVICE INDUSTRIAL APPLICATIONS

Open the catalog to page 2
Variable Frequency Drive DRIVE-TECH - 3

DRIVE-TECH - A NEW GENERATION OF VFD DRIVE-TECH The new line of VFD DrivE-Tech has been designed and developed to optimize, control and protect pumping systems built with different kind of pumps like vertical multistage, centrifugal and submersible. DrivE-Tech can work in applications like domestic, water supply, irrigation, commercial, HVAC, washing and more – it is suitable to operate in most of new or existing systems. The installation of a DrivE-Tech allows the user to gain important benefits like: Reduced energy consumption with remarkable cost saving Longer life of pumping system...

Open the catalog to page 3
Variable Frequency Drive DRIVE-TECH - 4

INSTALLATION TIPS AND SET UP OF DRIVE-TECH DrivE-Tech is designed to be installed on top of motor fan cover or fixed to a wall with its dedicated kit DrivE-Tech can be placed on top of pump motor with 4 customized clamps supplied with all type of VFD. In this type of installation the DrivE-Tech is cooled by the fan of motor. DrivE-Tech can be fixed to a wall with a customized support supplied as option. The cooling of the VFD is guarantee by an external fan attached to the radiator. WIRING OF DRIVE-TECH 1. Connect the DrivE-Tech to the pump’s motor. 2. Connect the DrivE-Tech to power...

Open the catalog to page 4
Variable Frequency Drive DRIVE-TECH - 5

EASY CONFIGURATION SOFTWARE When first powering the DrivE-Tech, an initial configuration is required for the complete setup of the drive. Additional parameters can be configured later by entering three different setting levels: End user level The only level which can be accessed without password. It allows the user to monitor electrical and hydraulic parameters and status of the DrivE-Tech and pump. Installer level In this level , the installer can configure the DrivE-Tech - pump system to the characteristics of the hydraulic system. An entry password is required. Advanced level This level...

Open the catalog to page 5
Variable Frequency Drive DRIVE-TECH - 6

ELECTRONIC TAILORED FOR PUMPS Minimum motor frequency This parameter prevents the pump from running lower below a certain speed, avoiding the risk of damaging the thrust bearing in submersible pumps. Minimum motor frequency ramp To prevent motor damage, the motor can accelerate quickly to reach the minimum motor frequency , and then is allowed to follow a lower start-up ramp. Stop function at zero water flow After reaching the minimum frequency at zero flow (Fmin Q=0) DrivE-Tech progressively slows the pump while monitoring the signal from the pressure transducer. If the pressure is close...

Open the catalog to page 6
Variable Frequency Drive DRIVE-TECH - 7

PERFORMANCE CHART Size Maximum Maximum imput current output current (A) (A) DrivE-Tech model * Typical motor power. It’s recomended refer to rated motor current when selecting DrivE-Tech model TECHNICAL FEATURES Power frequency: 50 - 60 Hz (±2%) Max. ambient temperature at nominal current: 40 °C (104 °F) Max. altitude at nominal current: 1000 m Grade of protection: IP55 (Size 1, 2), IP54 (Size 3) 181 mm Settable digital output signals (N.O or N.C): 1. Motor run signal 2. Alarm signal 3. DOL 1 pump signal 4. DOL 2 pump signal Analog input (10 or 15 Vdc): 1. 4-20 mA 2. 4-20 mA 3. 4-20 mA / 0...

Open the catalog to page 7
Variable Frequency Drive DRIVE-TECH - 8

Franklin Electric S.r.l. Via Asolo, 7 - 36031 Dueville (Vicenza) Italy Phone. +39 0444 361114 - Fax. +39 0444 365247 Contacts: sales.it@fele.com Single member - Company subject to the control and coordination of Franklin Electric Co., Inc. NOTE: Franklin Electric s.r.l. reserves the right to amend specification without prior notice

Open the catalog to page 8

All Franklin Electric catalogs and technical brochures

  1. Control boxes

    17 Pages

  2. VN SERIES

    4 Pages

  3. 60HZ MH SERIES

    22 Pages

  4. SURFACE PUMPS

    548 Pages