General Technical Data
The OSE-C 1001 control unit is designed for surface mounting and utilizes a 3-wire input type of sensing edge. It features relay NCC outputs and additional reverse contact outputs (NOC). The unit operates on a supply voltage of 24 V AC/DC and functions within a temperature range of -20 °C to +55 °C. It weighs 0.34 kg and is housed in ABS material with protection class IP65. The dimensions are 90x48.5x40 mm, and it consumes 1.5 W of power with a cyclic duration factor of 100%. It supports one optical sensing edge input.

Safety Properties
The unit complies with Safety Category 2 PL c according to EN 13849-1, with an MTTFd of 51 years and a diagnostic coverage of 89%.

Sensing Edge Output
The output type is NC/COM relay, with a maximum switching voltage of 120 V AC / 60 V DC and a maximum switching current of 0.5 A at 120 V AC or 1 A at 24 V DC. The minimum switching current is 1 mA at 1 V DC. Fusing is required at 0.5 A slow acting, which is not part of the unit.

Reverse Output
The reverse output type is Relay NO/COM, with similar maximum switching voltage and current specifications as the sensing edge output. Fusing is also required at 0.5 A slow blowing, not included in the unit.

Product Life Cycle
The product is in the established phase of its life cycle.

Compatible OSE Sensors
The control unit is compatible with various OSE sensors, each with specific T and R cable lengths. Examples include OSE-S 6501 with 6.5 m T cable and 0.5 m R cable, and OSE-S 6512 with both T and R cables at 10.5 m.

Contact Information
For further inquiries, contact CEDES AG at [email protected]. Note that all dimensions are provided in both inches and millimeters, and the information is for general presentation purposes only. Detailed technical drawings are available in the "Download" section.
See more

Catalog excerpts

OSE-C 1001-1

Control Unit OSE-C 1001 General Technical Data Housing Type Surface Mounting Input Type of Sensing Edge Additional Outputs Supply Voltage Operation Temperature Housing Material Protection Class Housing Dimensions Power Consumption Cyclic Duration Factor Number of Optical Sensing Edge Inputs Safety Properties Safety Properties Sensing Edge Output Output Type NC/COM Relay Data Sheet Printed at 28-10-2022 08:10 -1/4

 Open the catalog to page 1
OSE-C 1001-2

0.5 A slow acting (not part of the unit) Reverse Output Output Type Relay NO/COM 0.5 A slow blowing (not part of unit) Product Life Cycle Compatible Ose Sensors Product Data Sheet Printed at 28-10-2022 08:10 -2/4-

 Open the catalog to page 2
OSE-C 1001-3

Data Sheet Printed at 28-10-2022 08:10 -3/4-

 Open the catalog to page 3
OSE-C 1001-4

All dimension in [inch] mm. This drawing and the information contained is for general presentation purposes only. Please refer to the "Download" section for detailed technical drawings.© CEDES AG., All rights reserved. We do not assume responsibility for technical inaccuracies or omissions. Specifications are subject to change without notice. Data Sheet Printed at 28-10-2022 08:10 -4/4-

 Open the catalog to page 4

All FRABA VITECTOR catalogs and technical brochures

  1. OSE-C 4024

    3  Pages

  2. OSE-C 4524

    3  Pages

  3. OSE-C 5024

    3  Pages

  4. OSE-C 1003

    3  Pages

  5. OSE-C 1004

    3  Pages

  6. OSE-C 2323

    5  Pages

  7. OSE-C 2301

    4  Pages

  8. OSE-C 2300

    4  Pages

  9. OSE-C 2324

    5  Pages

  10. PRODUCT OVERVIEW

    130  Pages

  11. OSE-B 5518

    2  Pages

  12. OSE-B 7428

    2  Pages

  13. OSE-B 8828

    2  Pages

  14. OSE-B 3035

    2  Pages

  15. OSE-B 2528

    2  Pages

  16. OSE-B 2518

    2  Pages

  17. OSE-B 2212

    2  Pages

  18. OSE-S 1172

    4  Pages

  19. OSE-S 1171

    4  Pages

  20. OSE-S 1102

    4  Pages

  21. OSE-S 1100

    4  Pages

  22. OPC-S 4501

    5  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.