EGT 130, 330, 332, 335, 430: Room-temperature sensor, - 1

Product data sheet EGT 130, 330, 332, 335, 430: Room-temperature sensor, surface-mounted How energy efficiency is improved Precise measurement of room temperature for energy-efficient control of HVAC installations and monitoring energy consumption Features • Passive measuring element • Temperature measurement in dry rooms • Variants with setpoint adjuster, presence button and status LED EGT*30F*** Technical data Power supply Power supply Time constant in still air Storage and transport temperature Admissible ambient temperature Parameters Time characteristic Pure white, similar to RAL9010 Ambient conditions Construction Housing material Cable inlet From rear or side top/bottom Connection terminals Standards, directives Type of protection EGT130F031: EN 60730-1 (mode of operation 1, residential premises) Resistance values / The tolerance listed below applies only to the corresponding measuring element. The accuracy of the sensor depends on the cable length and the measuring element used. Measuring element Nominal value Overview of passive types Type Measuring range Output signal EGT 335 with presence button and 3 LEDs Right of amendment reserved © 2

Open the catalog to page 1
EGT 130, 330, 332, 335, 430: Room-temperature sensor, - 2

Product data sheet Active Type Measuring range Measuring ac- Output signal curacy at 21 °C EGT130F031 3 temperature ranges, adjustable on device (see connection diagram) Power supply Description of operation The resistance of the nickel shunt changes according to the temperature. The temperature coefficient is always positive, which means the resistance increases along with the temperature. The elements can be exchanged within the specified tolerance ranges. EGT 335: The LEDs can be controlled individually (see connection diagram) and can signal 3 different operating statuses, for example:...

Open the catalog to page 2
EGT 130, 330, 332, 335, 430: Room-temperature sensor, - 3

Product data sheet urements. Heating pipes inside the walls can also affect the measurement. Do not use silicone or similar materials to seal the pipes in the wall. Right of amendment reserved © 2016 Fr. Sauter AG

Open the catalog to page 3
EGT 130, 330, 332, 335, 430: Room-temperature sensor, - 4

Product data sheet Fr. Sauter AG Im Surinam 55 CH-4016 Basel Tel. +41 61 - 695 55 55 www.sauter-controls.com Right of amendment reserved © 2016 Fr. Sauter AG

Open the catalog to page 4