EGQ 220, 222: Room transducer, CO2 , surface-mounted

EGQ 220, 222: Room transducer, CO2 , surface-mounted

EGQ 220, 222: Room transducer, CO2 , surface-mounted

Product catalog summary
Overview: The EGQ 220 and 222 are room transducers designed for measuring CO2 concentration and temperature (EGQ 222 only) to enhance energy efficiency by controlling room climate. They are suitable for environments like offices and classrooms, offering demand-controlled ventilation.

Features:
  • Selective CO2 measurement for demand-controlled ventilation.
  • Available with or without temperature measurement.
  • Utilizes NDIR dual-beam technology for stable, long-term performance.
  • Calibrated and ready for immediate use.
  • Fast response to CO2 concentration changes.
  • Temperature-compensated calibration for standard air pressure.
  • Developed according to DIN EN 13779, DIN EN 15251, VDI 6038, and 6040 directives.

Technical Data:
  • Power Supply: 15-24 V= (±10%) or 24 V~ (±10%).
  • Power Consumption: Max. 3 W (24 V=) | 6 VA (24 V~).
  • CO2 Measuring Range: 0-2000 ppm with accuracy of ±75 ppm.
  • Temperature Range (EGQ 222): 0-50 °C with accuracy of ±1%.
  • Ambient Conditions: Temperature 0-50 °C, Humidity max. 85% rh non-condensing.

Standards and Directives: Complies with IP30 protection, CE conformity, and RoHS Directive.

Operation: The transducer measures CO2 using a dual-beam reference process, converting it to a 0-10 V signal. It compensates for ageing and contamination effects, requiring no fresh air for calibration.

Intended Use: Designed for measuring CO2 in residential and office environments. Not suitable for safety applications.

Installation Notes: Must be installed by a qualified electrician. Shielded cables recommended in high-interference environments. Avoid installation near heat sources or in direct sunlight.

Room Air Quality: Defined by DIN EN 13779 with categories IDA1 to IDA4 based on CO2 concentration levels.

Maintenance: Sensors require regular recalibration due to drift, but dual-beam technology offers automatic self-calibration.

Disposal: Follow local laws for disposal. More information available in the product's material declaration.
See more

Catalog excerpts

EGQ 220, 222: Room transducer, CO2 , surface-mounted-1

Product data sheet EGQ 220, 222: Room transducer, CO2, surface-mounted How energy efficiency is improved Measuring the CO2 concentration for energy-efficient control of the room climate Features • Selective measurement of the CO2 concentration for demand-controlled ventilation of rooms (e.g. meeting rooms, conference rooms, offices, classrooms, etc.) • Available in 2 versions: with and without temperature measurement • CO2 measurement with NDIR1} Dual-beam technology, therefore stable in the long term and largely resistant to external influences • Suitable for 24-hour operation • Calibrated ex works and ready to use immediately • Very fast response to changes in the CO2 concentration in rooms • Temperature-compensated calibration for the standard air pressure of 1013 mbar • The sensors have been developed according to the DIN EN 13779, DIN EN 15251, VDI 6038 and 6040 directives Technical data Power supply Power consumption Max. 3 W (24 V=) | 6 VA (24 V~) Peak inrush current 10 A, 2 ms Parameters Time characteristic In room (0.1 m/s) 2 minutes 21 °C) Pressure dependence Typ.0.135% of the measured value Gradual drift2) < 5% FS or < 10% per year Measuring accuracy ±1% of measuring range (typ. at Ambient conditions Admissible ambient humidity Max. 85% rh non-condensing Construction Connection terminals Screw terminal, max. 1.5 mm2 Cable inlet From behind, top bottom Housing Pure white Housing material ASA Type of protection IP30 according to EN 60529 EMC Directive 2004/108/EC EN 60730-1. Mode of operation 1. Residential premises RoHS Directive 2011/65/EU EN 50581 1 NDIR: Non-dispersive infrared sensor 2) Air flow speed 0,15 m/s, air flow direction, laminar from below upwards. ^ SAUTER Right of amendment reserved © 2015 Fr. Sauter AG

 Open the catalog to page 1
EGQ 220, 222: Room transducer, CO2 , surface-mounted-2

Product data sheet Description Readiness for operation Output signal ^ SAUTER Right of amendment reserved © 2015 Fr. Sauter AG

 Open the catalog to page 2
EGQ 220, 222: Room transducer, CO2 , surface-mounted-3

Product data sheet Note Too much dust in the air can impair the air circulation in the CO2 sensor and cause measurement errors. Heat caused by dissipated electric power Temperature sensors with electronic components are always subject to a certain amount of power loss, which affects the temperature measurement of the ambient air. In active temperature sensors, the higher the operating voltage, the greater the power loss. This power loss must be taken into account in the temperature measurement. At a fixed operating voltage (±0.2 V), this is normally done by adding or subtracting a constant offset...

 Open the catalog to page 3
EGQ 220, 222: Room transducer, CO2 , surface-mounted-4

Product data sheet Power supply Voltage drop Voltage drop Fr. Sauter AG Im Surinam 55 CH-4016 Basel Tel. +41 61 - 695 55 55 www.sauter-controls.com ^ SAUTER Right of amendment reserved © 2015 Fr. Sauter AG

 Open the catalog to page 4

All Fr. Sauter AG catalogs and technical brochures

  1. SAUTER Catalogue

    551  Pages

  2. EQJW 24

    8  Pages

  3. NRT 101

    8  Pages

  4. Thermowells

    6  Pages

  5. SAUTER EGQ

    4  Pages

  6. TFL 201

    3  Pages

  7. TLC

    2  Pages

  8. TSHK 670...67

    3  Pages

  9. SAUTER FACTS

    28  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.