Overview: The document provides technical specifications and operational details for the DSU and DSI pressure transmitters, designed for measuring pressure in liquids, gases, and vapors. These devices convert pressure into a proportional standard signal, enhancing energy efficiency.
Features:
  • Measures pressure in various media with high precision.
  • Equipped with a sturdy ceramic diaphragm and stainless steel pressure sensor for corrosive environments.
  • Offers high positive pressure protection, vibration resistance, and low hysteresis.
  • Standard output signals of 2...10 V or 4...20 mA.
  • Complies with DIN EN 175301-803-A for plug connections.
Technical Data:
  • Power Supply: Two-wire (24 V=, 0.7 W) and three-wire (24 V=/~, 0.5 W).
  • Temperature Dependence: Zero point 0.07% FS/K, measuring range 0.05% FS/K.
  • Ambient Conditions: Temperature range 0...60 °C, medium temperature up to 85 °C, humidity 45...75% rh.
  • Construction: Chromium-nickel steel housing, IP65 protection, and CE conformity.
Standards and Directives: The device meets IP65 protection standards and conforms to CE directives, including EMC Directive 2004/108/EC.
Types and Specifications:
  • DSU models offer a measuring range from 0...2.5 bar to 0...25 bar with a 0...10 V output signal.
  • DSI models provide a similar range with a 4...20 mA output signal.
Operation: The pressure is applied to a ceramic diaphragm, causing deformation. This deformation alters the strain gauge output, which is converted into standard electrical signals by integrated electronics.
Intended Use: The product is intended for specific applications as described and should not be altered or converted.
Materials: Contact materials include stainless steel, ceramic, and fluoroelastomer seals.
Disposal: Disposal must comply with local laws, with further material information available in the product's environmental declaration.
Accessories: Includes capillary throttle and wall bracket options.
See more

Catalog excerpts

DSU, DSI: Pressure transmitter-1

Product data sheet DSU, DSI: Pressure transmitter How energy efficiency is improved Simple conversion of pressure to proportional standard signal For measuring pressure in liquids, gases and vapours Sturdy device with ceramic diaphragm High precision High positive pressure protection High vibration resistance Low hysteresis Standard signal 2...10 V or 4...20 mA Pressure sensor made of stainless steel for corrosive media With standard plug as per DIN EN 175301-803-A Technical data Power supply Power supply Electrical connection DSI:two-wire DSU:three-wire Power consumption Temperature dependence Zero point 0.07% FS/K Measuring range 0.05% FS/K Admissible ambient temperature Admissible temperature of medium Admissible ambient humidity Ambient conditions Construction Housing material Device plug Plug connection 4-pin, standard plug DIN EN 175 01-803-A, cable gland M12 Cable cross-section Pressure connection Standards and directives Protection class Subject to Art. 3.3 of PED without safety function Overview of types Type Measuring range (bar) Output signal Power supply Maximum pressure Right of amendment reserved © 2016 Fr.

 Open the catalog to page 1
DSU, DSI: Pressure transmitter-2

Product data sheet Measuring range (bar) Output signal Power supply Maximum pressure Accessories Description Capillary throttle, stainless steel, length 1 m, G½"-G½" Wall bracket for DSU/DSI Description of operation The pressure to be measured is exerted directly onto a ceramic diaphragm that deforms when pressure is applied. A strain gauge with a measuring bridge is fitted to the ceramic diaphragm. The deformation of the ceramic changes the output signal of the strain gauge. Electronics integrated into the device convert the bridge signals of the strain gauge into electric standard signals 4...20...

 Open the catalog to page 2
DSU, DSI: Pressure transmitter-3

Product data sheet Input signal Power supply Output signal Pressure transmitter Input signal Output signal Right of amendment reserved © 2016 Fr. Sauter AG

 Open the catalog to page 3
DSU, DSI: Pressure transmitter-4

Product data sheet Screw plug hole acc. to DIN EN 837-1 Hex-wrench SW27 Male connection stem acc. to DIN EN 837-1 Fr. Sauter AG Im Surinam 55 CH-4016 Basel Tel. +41 61 - 695 55 55 www.sauter-controls.com Right of amendment reserved © 2016 Fr. Sauter AG

 Open the catalog to page 4

All Fr. Sauter AG catalogs and technical brochures

  1. SAUTER Catalogue

    551  Pages

  2. EQJW 24

    8  Pages

  3. NRT 101

    8  Pages

  4. Thermowells

    6  Pages

  5. SAUTER EGQ

    4  Pages

  6. TFL 201

    3  Pages

  7. TLC

    2  Pages

  8. TSHK 670...67

    3  Pages

  9. SAUTER FACTS

    28  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.