Catalog excerpts
Product data sheet ASM 134: Damper actuator Improving energy efficiency Torque-dependent cut-off facility for efficient usage of energy For controllers with a switching (3-point) output For operating air dampers, shut-off dampers, butterfly valves and multi-leaf dampers Self-centring spindle adapter Gear unit can be disengaged to position the damper and for manual adjustment Stepping motor with electronic activation and cut-out Direction of rotation changed by transposing the connections Suitable for all fitting positions Maintenance-free Version with halogen-free cable on demand Technical data Power supply Power supply Power consumption Torque and holding torque Admissible damper shaft Admissible damper shaft (hardness) Operating noise Response time Admissible ambient temperature Admissible ambient humidity Lower section black, upper section yellow Housing material Fire-retardant plastic Power cable Protection class Ambient conditions Over-voltage categories Overview of types Type Power consumption during operation Power consumption when idle Accessories Type Assembly materials for M3R/M4R, MH32F/MH42F with ASM 124 Auxiliary change-over contacts, single Right of amendment reserved © 2
Open the catalog to page 1Product data sheet Auxiliary change-over contacts, double Fitting bracket Spindle extension with coupling Lever, fitting strip Driver axle for auxiliary contacts Spindle for clamping lever 0370059 Auxiliary change-over contacts: Infinitely variable 0...90°, admissible load 5(2) A, 24...230 V Description of operation When voltage is applied to the cable (2a or 2b), the control unit to be activated is moved to any desired position. Direction of rotation (viewing the spindle adaptor from the actuator): • The coupling piece turns in the clockwise direction, with the voltage on the brown cable...
Open the catalog to page 2Product data sheet Factory setting position Disposal When disposing of the product, observe the currently applicable local laws. More information on materials can be found in the Declaration on materials and the environment for this product. Connection diagram Direction of operation 1: 2a closed, 2b open Direction of operation 2: 2b closed, 2a open Right of amendment reserved © 2015 Fr. Sauter AG
Open the catalog to page 3Product data sheet Dimension drawing Fr. Sauter AG Im Surinam 55 CH-4016 Basel Tel. +41 61 - 695 55 55 www.sauter-controls.com Right of amendment reserved © 2015 Fr. Sauter A
Open the catalog to page 4All Fr. Sauter AG catalogs and technical brochures
-
SAUTER Catalogue
551 Pages
-
HSC 120: Room humidistat
3 Pages
-
SAUTER AXT2 and AXS2.
8 Pages
-
Ball valve and actuator.
6 Pages
-
SAUTER Valveco compact
8 Pages
-
Valves and actuators.
32 Pages
-
SAUTER vialoq AVM 100
2 Pages
-
SAUTER flexotron ® 400
4 Pages
-
EXG: Active potentiometer
2 Pages
-
flexotron ® 2000
2 Pages
-
SAUTER flexotron800
8 Pages
-
EQJW 24
8 Pages
-
NRT 101
8 Pages
-
Thermowells
6 Pages
-
Indoor air quality
8 Pages
-
SAUTER EGQ
4 Pages
-
SAUTER equiflex ® NRT300
4 Pages
-
SAUTER HSC/HBC humidistats
2 Pages
-
DSA: Pressure switch
4 Pages
-
TFL 201
3 Pages
-
TUC: Universal thermostat
5 Pages
-
TLC
2 Pages
-
TSHK 670...67
3 Pages
-
TSHK 621...643
4 Pages
-
TSO, TSH: Room thermostat
4 Pages
-
RAK: Universal thermostat
5 Pages
-
SAUTER FACTS
28 Pages
-
Pressure transducer
3 Pages
-
Air-flow transducer
2 Pages