Catalog excerpts
XDSTM Multipurpose NIR-analyser for Laboratories The multipurpose NIR-analyser for laboratories with ISIscan™ software, provides rapid non-destructive analysis of virtually any solid, viscous and liquid samples making it ideal for research as well as commercial laboratories. The XDS analyser uses advanced NIR technology and is equipped with a full spectrum, 400-2500 nm, research grade spectrometer for maximum analytical performance and full flexibility in your choice of analytical parameters. Solid, liquid and viscous samples The versatile NIR analyser allows laboratories to build their own calibrations - for any samples and parameters that are suitable for NIR For example: Multiparameter incl. protein, fat, moisture, fibre, starch, amino acids, & more Dedicated Analytical Solutions
Open the catalog to page 1Ideal for laboratory and research Network-Ready - XDS NIR analysers are designed to be operated over a network. Data archival and retrieval, spectral database management, performance verification or remote operation can be accessed through this network for improved method development and remote support assistance. The versatile XDS Analysers offer simple and rapid analysis of liquid and/or solid and viscous samples depending on the application. The flexible sample presentation makes it ideal for testing of diverse samples. Samples can be tested in their original vials, bags or bottles or...
Open the catalog to page 2Technology The XDS advantage The technical excellence provided by XDS ensures simplicity of use, efficient operations and the capacity to handle a wide range of sample types. Specific advantages include: • Superior analytical performance providing high quality results in less than 60 seconds • nstrument standardisation that reduces calibration costs I by allowing the same calibration to be used on different instruments • Flexible sample presentation allows samples to be analysed in standard XDS sample cups, disposable bags, glass vials, beakers or quartz cuvettes with different path-lengths...
Open the catalog to page 3For routine analysis or research laboratory application ISIscan™ software For research laboratory applications, the broad scanning range (400 –2500 nm) (VIS and NIR) and the flexible sample presentation provides a highly versatile analysis platform that is both accurate and fast. ISIscan™ is a powerful tool for routine and diagnostic reporting and integration of results into your LIMS or process system. The software stores all results, settings and calibrations, giving you full traceability for your NIR results. It is simple to retrieve historical data and export it in any of several...
Open the catalog to page 4Ordering information XDS™ NIR Rapid Content Analyser Typical system configuration*: XDS™ NIR Rapid Content Analyser includes: 1 pcs XDS laboratory monochromator 1 pcs XDS™ NIR Rapid Content module with solid module 1 pcs XDS RCA iris 1 pcs NIRStandards™ certified standard 1 pcs ISIscan™ 1 pcs XDS accessory kit 1 pcs XDS™ NIR Rapid Content Analyser installation and operation manual Accessories: Mini sample cup set Coarse granular sample cell Liquid sample kit for RCA WinISI™ IV calibration development software NIRStandard certified reflectance standard XDS™ NIR Rapid Liquid Analyser Typical...
Open the catalog to page 5NEW: Extended warranty on new instruments with a FossCare agreement Secure your investment with a FossCare™ Support Agreement Let FOSS take care of you for a maximum return on your analytical investment. Get a four year warranty as part of the new FossCare Premium Preventive Maintenance Agreement or two years as part of any other FossCare agreement. In addition to the peace of mind afforded by the warranty period, the continual preventive maintenance pays off by keeping your analytical instruments working perfectly every day, year after year. Why preventive maintenance? As with any...
Open the catalog to page 6Technical specifications XDS Rapid Content™ Sample type Solid, liquids/semi-liquids & viscous Example parameters Multiparameter incl. protein, fat, mois- FFA, moisture, Phospohorous, IV, ture, fibre, starch, amino acids, & more K232, K270, PV Sample presentation XDS sample cups, disposable bags, Quarts cuvettes with different pathglass vials or beakers lengths or disposable vials Swappable modules Sample temperature control NIST traceable performance test Transferable calibrations Auto Sampler Wavelength range Operating temperature Operating humidity Dual detector system Silicon...
Open the catalog to page 7All Foss Analytical catalogs and technical brochures
-
Grain, Milling and Oils Segment
24 Pages
-
Infratec™ NOVA
9 Pages
-
NIRS™ DS2500 Flour Analyser
6 Pages
-
Fibertec™ 8000
6 Pages
-
Crude Fat
7 Pages
-
Extractable Matter
7 Pages
-
Total Fat
9 Pages
-
Kjeltec™ 8000
10 Pages
-
Mill Collection
11 Pages
-
ProFoss™ Soya
9 Pages
-
MeatScan™
6 Pages
-
MeatMaster™ II
10 Pages
-
Olivia™
6 Pages
-
NIRS™ DA1650
7 Pages
-
NIRS™ DS2500 F
8 Pages
-
FOODSCAN MEAT
6 Pages
-
FOODSCAN DIARY
7 Pages
-
DUMATEC 8000
10 Pages
-
EYEFOSS
4 Pages
-
MILKOSCAN FT+
7 Pages
-
FOSSOMATIC FC
7 Pages
-
CENTRAL MILK TESTING
24 Pages
-
BACTOSCAN FC+
8 Pages
-
GRAIN, MILLING AND OILS
24 Pages
-
ALPHATEC F№
6 Pages
-
KT 200 Kjeltec™
7 Pages
-
Infratec NOVA
9 Pages