1. Catalogs
  2. ForTest GmbH
  3. T8890 Bi-channel Air Leak Tester - Datasheet

T8890 Bi-channel Air Leak Tester - Datasheet

T8890 Bi-channel Air Leak Tester - Datasheet

T8890 Bi-channel Air Leak Tester - Datasheet

Product catalog summary
Overview: The T8890 is a two-channel leak tester by ForTest, designed to be compact and efficient, housed in the same case as the single-channel T8990. It offers three types of pressure adjustment: single manual, double manual, and single automatic electronic regulator. This device is ideal for testing pairs of lights or parts with double compartments, effectively halving test times while maintaining flexibility and reliability.
Key Features:
  • Fast parameter programming with a new numerical keyboard and a large display for clear test cycle viewing.
  • Limitless connectivity with USB, RS232, RS485, Can bus, and TTY ports, and a master USB port for data storage and firmware upgrades.
  • Advanced measurement capabilities with a 6.2” color split screen and a full-area touch screen.
  • Optimized pneumatic section with a 30% increase in filling speed due to new generation valves.
  • Innovative design with a user-friendly interface, easy cleaning, and a robust build suitable for laboratory and production line use.
Technical Specifications:
  • Resolution from 0.1 Pa with a real measurement resolution of 0.1 Pa at 1 bar.
  • Measurement range from -1 to 20 bar with an accuracy of 0.5% RDS+3DGT.
  • Dimensions: 270 x 160 x 300 mm; Weight: 8 Kg.
  • Electrical supply options: 24VDC, 110 VAC, 230 VAC.
Test Modes: The T8890 supports leak testing and obstruction testing, with 300 test programs available.
Optional Features: Includes electronic regulator, AUX I/O, communication interfaces, pneumatic fast filling, pre-filling, and volume measurement capabilities.
Application Sectors: Suitable for aerospace, automotive, household appliances, electronics, medical, and more.
Communication Interfaces: Supports RS232/RS485, USB-Serial, Ethernet TCP/IP, Profinet, and EtherCAT with various protocols like ForTest, Modbus RTU, and Trace EOT.
See more

Catalog excerpts

T8890 Bi-channel Air Leak Tester - Datasheet-1

FORTEST T8890 BICHANNEL STANDARD LEVEL LEAK TESTER Two channel leak tester. T8890 is the two channel equipment by ForTest enclosed in the same case of the single channel T8990, making it the most compact in its category. It is available with 3 types of pressure adjustment: single manual regulator, double manual regulator and single automatic electronic regulator. Ideal to test pairs of lights or parts with double compartments. It can half test times, however maintaining the flexibility and reliability of the T8990. Parameter programming is much faster thanks to the new numerical keyboard integrated in the menus, and the big display makes viewing even clearer of the test cycle. The main screen also enables interaction with shortcut functions, such as test program change, “smart" test archive menu and locking/unlocking using a password. Limitless connectivity. The new T8890 equipment includes ports for the USB slave, RS232, RS485, Can bus and TTY. The front panel has a master USB port for connection to a USB key to save the tests results, backup/restore parameters and upgrade firmware equipment. The connection to thermal printers, barcode/data-matrix readers and markers takes place automatically using an internal menu. ^ :<f: Q <•••> Usb key High power RS232, RS485, Can Ethernet and outputs auxiliary connector centring technology in windows and the double Faraday optical-isolated cage, which reduces the settling times under 18 ms. This gives a real measurement resolution of 0.1 Pa at 1 bar (0.5 Pa at 6 bar), stable and noise-free. lg) Built-in processor Centring Resolution and coprocessor technology from 0.1 Pa in windows Optimised pneumatic section. Assembly of the latest generation valves has enabled a 30% increase in the filling speed compared to the previous model, maintaining reliability unaltered over time. Our tools do not require expensive maintenance in the pneumatic department. Actually, our objective is to make them increasingly reliable and long-lasting. (!>S ® NO* Filling speed High strength No periodic +30% against humidity maintenance Innovative design. What appears to be a simple design exercise, in fact hides an in-depth study to make use and understanding of the equipment as simple as possible. The front panel is made of a single sheet of tempered glass and aluminium, which makes it extremely easy to clean, making the T8890 suitable for use in the laboratory and on the production line. The extensive internal menus are easy to understand and the graphic interface was designed to only display important information. Everything is exactly where it should be. Always better measurements. The test cycle was further accelerated thanks to processor and coprocessor interaction, maintaining the reliability that has always made ForTest unique. We can say with certainty that T8890 avails of the most advanced measurement section in the world, thanks to the User-friendly Interface <3603 Easy to clean Use in sectors ForTest group - www.fortest.com - [email protected]

 Open the catalog to page 1
T8890 Bi-channel Air Leak Tester - Datasheet-2

FORTEST T8890 BICHANNEL STANDARD LEVEL LEAK TESTER Interface Name Application SectorsMeasurement Caracteristics Optional • Electronic regulator • AUX I/O 24VDC with 8 output programmable, 4 input programmable, 4BCD • Communication interfaces • Pneumatic fast filling • Volume measurement • HMI touchscreen controller • Colour display • USB pen drive for store results and test parameters • Bluetooth Low Energy and WiFi interfaces on-board • Real Time Graph of pressure and decay • 300 Test Programs • USB Type-B female connector for PC • 6 Languages (English, Italian, French, German, Spanish, Portuguese)...

 Open the catalog to page 2
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.