Overview: The T6060 is an entry-level differential leak tester by ForTest, designed to offer high measurement performance comparable to higher-end models. It features a compact design with a user-friendly interface and advanced measurement capabilities.
Specifications: The T6060 provides a measurement resolution from 0.1 Pa up to 6 bar, with a direct pressure accuracy of 0.5% FS. It supports a range of units including mbar, bar, psi, and more. The device dimensions are 180 x 160 x 200 mm, and it weighs 5 kg.
Features: Key features include a 3.5” color display, a touch screen capacitive keyboard, and a tempered glass panel for easy cleaning. It supports USB, RS232, RS485, and CAN bus connections, and includes Bluetooth Low Energy and WiFi interfaces. The device can store up to 99 test programs and supports firmware upgrades via USB.
Applications: The T6060 is suitable for various sectors such as aerospace, automotive, household appliances, electronics, medical, and more. It is designed for use in both laboratory and production line settings.
Test Modes: The primary test mode is the Differential Leak Test, which benefits from the device's high sensitivity and resolution capabilities.
Accessories: Available accessories include a barcode reader, label printer, Leak Test Manager PC software, air filter, and an external Start/Stop push button.
Communication Interfaces: The T6060 supports standard protocols such as ForTest, Modbus RTU, and Trace EOT through its RS232/RS485 and USB-Serial interfaces.
See more

Catalog excerpts

T6060 DIFFERENTIAL ENTRY-LEVEL LEAK TESTER-1

DATA SHEET T6060 DIFFERENTIAL ENTRY-LEVEL LEAK TESTER Always better measurements. T6060 can count on a measurement resolution of 0.1 Pa to 1 bar (0.5 Pa to 6 bar) stable and noise-free, sharing a part of the measurement section implemented on the higher series T8000 and T9000. Despite being designed as an entry-level equipment, the measurement performance is absolutely comparable to those of the rest of the ForTest range. By nature, differential technology enables a measurement sensitivity even better than absolute decay, guaranteeing a decay resolution of 0.1 Pa up to 6 bar testing. The implementation of new pressure sensors, combined with the measurement section with centring technology in windows and double Faraday optical-isolated cage made further improvement of the tool performance. Advanced measurement performance Differential technology All the connections you need. T6060 has a more limited port supply than high level range, but is equally complete: a USB slave port, RS232, RS485 and CAN bus. The front panel has a master USB port assembled on it for connection to a USB key to save the tests conducted, backup/restore parameters and upgrade tool firmware. The connection to thermal printers, barcode/data-matrix readers and markers takes place automatically using an internal menu. High power outputs Everything is where it should be. Despite the compact dimensions which made use of more simplified menus necessary, the T6060 user interface was however designed to facilitate programming of the test parameters. The front panel is made of a single sheet of tempered glass and aluminium, which makes it extremely easy to clean, making the T6060 suitable for use in the laboratory and on the production line. The extensive internal menus are easy to understand and the graphic interface was designed to only display important information. Everything is exactly where it should be. Always easier. T6060 enhanced the user interface, thanks to an innovative tempered glass panel with built-in capacitive keyboard, around a 3.5” colour display. The new, high resolution display makes it even easier to view the test cycle and the programming menus, and the capacitive keyboard allows fast parameter entry. Centring technology in windows User-friendly interface Touch screen capacitive keyboard ForTest group - www.fortest.com - [email protected]

 Open the catalog to page 1
T6060 DIFFERENTIAL ENTRY-LEVEL LEAK TESTER-2

DATA SHEET T6060 DIFFERENTIAL ENTRY-LEVEL LEAK TESTER Application Sectors Technical Specifications Household Appliances ∆p(Leak) Direct Pressure Dimensions 180 x 160 x 200 mm Weight 5 Kg Electrical Supply 24VDC Air tube size: 4x2.7, 6x4, 8x6 Test Modes • Differential Leak Test Communication Interfaces Measurement Caracteristics Type Interface Name Accuracy Resolution From 0.001 mbar to 0.1 mbar ForTest, Modbus RTU, Trace EOT ForTest, Modbus RTU, Trace EOT Accessories Features • • • • • • • • • • • • • Resolution from 0.1 Pa Colour display USB pen drive for store results and test parameters Bluetooth...

 Open the catalog to page 2
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.