Industrial Endoscopes Endoscopes :: Fiberscopes :: Accessory INSPECT THE INSIDE. ON-SITE.
Open the catalog to page 1Choose the right equipment DIAMETER WORKING LENGTH Choose the right diameter for your application. To work without major interference, choose the This keeps the costs low and the image qality the working length thus providing better Choose the closest outer diameter of your probe to the inner diameter of your application. high, as well as enabling a robust stability inside highest working length necessary. Maybe the employment of a camera adapter will shorten inspection results. For access with straight sections, you should choose borescopes for your inspection. For access with bends and...
Open the catalog to page 2IMAGE PRESENTATION Consider direction of view (DOV), field of view (FOV) and zoom for the desired point of interest. To get sufficient inspection results, the application Choose the correct camera adapter to show to consider good illumination. easier. You can find all needed accessory and must be illuminated properly. Specificaly with the employment of a camera adapter, you need Oversized illumination causes unnecessary costs. the inspection on a monitor or save the results as digital files. The working process becomes camera adapters in this catalogue. Most Remote Visual Inspection tasks...
Open the catalog to page 3Call us for specific application details. We’re looking forward to your call! Contact us with a short description:
Open the catalog to page 4Industrial Endoscopes 1.1 Integrated visualization systems (0 0.7 mm to 4 mm] 02 1.2 Borescopes with interchangeable optics 03 1.4 Borescopes with fixed focus (0 1.9 mm to 4 mm] 12 1.5 Borescopes with wide angle optic (0 1.8 mm to 4 mm] 13 1.6 Swivel prism endoscopes (0 5.5 mm to 14 mm] 14 3.1 Articulating probe head (0 3.4 mm to 11 mm] 3.2 Non-articulating probe head (0 0.35 mm to 6.5 mm]
Open the catalog to page 5Borescopes are packed with high quality lens systems. The advantage of borescopes is its high image quality and robust construction. Employing mirror tubes, the direction of view can be changed. Furthermore, direction of view and field of view can be specified with lens systems. The benefits are the small outer diameter and a wide field of view. Choose the right borescope considering: :: :: :: :: :: :: :: :: :: :: Diameter Working length Direction of view (DOV) Field of view (FOV) Integrated visualization systems Borescopes with fixed focus Borescopes with interchangeable optics Swivel...
Open the catalog to page 61.1 Integrated visualization systems Control unit: White balance, GAIN (3 presets), window function (4 presets, ON/OFF switch, LED brightness control Video output: S-Video (Y/C), Composite Video (CVBS) Digital output: 1 x USB 2.0 Image sensor: 1/4“ CCD Image capture: 2:1 interlace Image resolution: PAL: 752 (H) x 582 (V) | NTSC: 768 (H) x 494 (V) Resolution: PAL: 625 lines | NTSC: 525 lines Storage temperature: +10°C to +60°C Dimensions control unit in mm: (W) 169 x (H) 62 x (D) 247 Weight control unit: 1,2 kg 17.000 Pixel 30.000 Pixel 50.000 Pixel 50.000 Pixel - Strengthening tubes COLOR...
Open the catalog to page 71.2 Borescopes with interchangeable optics OUTER Ø OPTIC LENGTH Interchangeable optics Objective tubes liquid-tight For mirror tubes Wide angle, 70° Mirror tubes COLOR CODE Wide angle, side view 90° COLOR CODE Wide angle COLOR CODE COLOR CODE
Open the catalog to page 81.2 Borescopes with interchangeable optics OUTER Ø OPTIC LENGTH Interchangeable optics Objective tubes liquid-tight Wide angle Mirror tubes COLOR CODE COLOR CODE COLOR CODE COLOR CODE
Open the catalog to page 91.2 Borescopes with interchangeable optics OUTER Ø OPTIC LENGTH Interchangeable optics Objective tubes liquid-tight Wide angle Mirror tubes COLOR CODE COLOR CODE COLOR CODE COLOR CODE
Open the catalog to page 10Mirror tubes COLOR CODE COLOR CODE
Open the catalog to page 111.3 Borescopes - focusable LENGTH Mirror tubes COLOR CODE COLOR CODE
Open the catalog to page 121.3 Borescopes - focusable OUTER Ø COLOR CODE Mirror tubes COLOR CODE
Open the catalog to page 141.3 Borescopes - focusable OUTER Ø Strengthening tubes COLOR CODE Mirror tubes COLOR CODE COLOR CODE
Open the catalog to page 151.3 Borescopes - focusable OUTER Ø COLOR CODE Mirror tubes COLOR CODE
Open the catalog to page 161.4 Borescopes with fixed focus LENGTH Strengthening tubes COLOR CODE COLOR CODE
Open the catalog to page 171.5 Borescopes with wide angle optic LENGTH COLOR CODE
Open the catalog to page 181.6 Swivel prism endoscopes OUTER Ø Swivel prism endoscopes COLOR CODE
Open the catalog to page 19COLOR CODE
Open the catalog to page 20with articulating / non-articulating probe head Even the smallest opening can provide the entrance for a fiberscope to give an overview of a complex application. Fiberscopes enable guidance through tube bendings and elbows. If necessary, choose your fiberscope with an articulating probe head. To adjust teh Remote Visual Inspection, we provide you with various accessories like side view adapters, different directions of view , fields of view and focal ranges. Choose the right fiberscope considering: :: :: :: :: :: :: Diameter Working length Direction of view (DOV) Field of view (FOV)...
Open the catalog to page 213.1 Articulating probe head OUTER Ø 3.4 mm 3.4 mm RESOLUTION 7.000 Pixel 7.000 Pixel COLOR CODE FLEXILUX fiberscopes VALUELINE fiberscopes COLOR CODE COLOR CODE Fiberscopes articulating ✓ = Included in scope of delivery COLOR CODE 17.000 Pixel 17.000 Pixel 17.000 Pixel 17.000 Pixel
Open the catalog to page 223.2 Non-articulating probe head OUTER Ø 0.35 mm 0.5 mm 0.5 mm Micro fiberscopes non-articulating 4.000 Pixel 4.000 Pixel 4.000 Pixel 6.000 Pixel 6.000 Pixel 6.000 Pixel 6.000 Pixel 6.000 Pixel 6.000 Pixel 10.000 Pixel 10.000 Pixel 17.000 Pixel 17.000 Pixel 30.000 Pixel 30.000 Pixel 30.000 Pixel 30.000 Pixel 30.000 Pixel 30.000 Pixel 30.000 Pixel 30.000 Pixel 30.000 Pixel 30.000 Pixel 30.000 Pixel 30.000 Pixel 30.000 Pixel 30.000 Pixel 30.000 Pixel 30.000 Pixel COLOR CODE Fiberscopes non-articulating COLOR CODE
Open the catalog to page 23Color temperature, light intensity and light guidance are important selection criteria based on purchase and maintenance costs. Fiber optics connect the light source with the endoscope. Flexible, straight or elastic fiber optics enable exact illumination. Contact us for advice with your application. Choose the right accessory considering: :: :: :: :: Color temperature Power Lifetime / Costs Illumination
Open the catalog to page 24All FORT IMAGING SYSTEMS catalogs and technical brochures
-
Videoscopes & Video endoscopes
34 Pages
-
INDUSTRIAL ENDOSCOPES
30 Pages
-
INVIZ UVin
2 Pages
-
INVIZ DE 2.4 / 4.0 mm
2 Pages
-
VUCAM XO
8 Pages
-
Revolver
4 Pages
-
Blending Scope
4 Pages
-
UVin
2 Pages
-
Pipe
2 Pages
-
Big
2 Pages
-
MatriX
8 Pages
-
Light Sources
1 Pages
-
Sabre 2.4 / 4.0
2 Pages
-
Visio Box
4 Pages
-
SNK
4 Pages
-
Retrieval Tool Kit
2 Pages
-
VUMAN RA-Y
8 Pages