Technical Specifications Overview:
- Power Requirements: The machine operates with a free running power of 0.9 kW/1.3 kW and a maximum power requirement of 2.9 kW/5.8 kW per hour.
- Emitted Power: The maximum high-frequency power emitted on the electrode is 5 kW/10 kW.
- Main Fuse: Type D with a capacity of 32 A.
- Voltage: Standard voltage is 3 x 400 V at 50 Hz/60 Hz, including neutral and earth connections.
- Working Frequency: The machine operates at a frequency of 27.12 MHz with a tolerance of ± 0.6%.
- Transmitting Tube: Type ITL 12-1, cooled by air.
- Flash Protection: Controlled by a thyristor.
- Pressure: Maximum pressure is 1400 kg at a minimum of 7 bar (101 psi).
- Air Consumption: The automatic system consumes a maximum of 140 l/min.
- Pneumatic Press: Equipped with an automatic pressure protection system (PSK).
- Machine Weight: The machine weighs 1000 kg, excluding the table.
- Welding Surface: Maximum welding surface per cycle is 200 cm²/400 cm².
- Computer Interface: Includes a 12” touch-screen with Forsstrom™ industrially developed, HF-classified computer.
- Table Measurements: Optional length with a height of 960 mm and width of 1000 mm, featuring a level 2 precision track system.
See more