Overview: The document provides technical specifications and operational details for the 'DISTATIC' series of solvent recovery systems by Formeco s.r.l., designed for recycling both flammable and non-flammable solvents. The systems are explosion-proof and ATEX approved, ensuring safe operation in hazardous environments.
Specifications:
  • Models: Di60 Ax LCD, Di120 Ax LCD, Di160 Ax LCD
  • Loading Capacities: 60, 120, and 160 litres respectively
  • Boiler Volumes: 103, 210, and 222 litres respectively
  • Processing Time: 4.00 - 5.30 hours
  • Working Temperature: 50 - 180 °C
  • Operating Pressure: Atmospheric
  • Electrical Supply: Single phase for Di60, three phases for Di120 and Di160
  • Connected Power: 3000 W, 7000 W, and 11200 W respectively
  • Electrical Protection: II2G IIA T3 to T2
  • Vapour Condenser: Stainless steel, air-cooled (optional water-cooled version available)
Functioning Principle: The systems utilize a distillation process to separate contaminants from solvents. The solvent is heated using a diathermic oil jacket, and vapors are condensed and collected for reuse. Contaminants are left as residue in 'Rec-Bag' or by tilting the unit.
Additional Features:
  • Rec Bag: Disposable bags for easy disposal of solid contaminants, enhancing distillation yield.
  • Control: LCD control board for time regulation.
Terms and Definitions:
  • DIstatic: Distillation units with tilting boilers for residue unloading.
  • Di: Explosion-proof units suitable for zone 1 environments.
  • Ax: Air condenser made of stainless steel.
  • LCD: Liquid crystal display for control.
See more

Catalog excerpts

SOLVENT RECOVERY SYSTEMS-1

SOLVENT RECOVERY SYSTEMS Professional Formeco s.r.l. Via Cellini, 33 35027 Noventa Padovana Padova – Italy – www.formeco.com

 Open the catalog to page 1
SOLVENT RECOVERY SYSTEMS-2

SERIES STANDARD “DISTATIC” Model Explosion proof version ATEX approved For recycling of flammable and not flammable solvents Loading capacity: 60 litres Total volume of the boiler: 103 litres Inner diameter of the boiler: 400 mm Processing time: hours 4,00 - 5,30 Working temperature: 50 - 180 °C Operating: atmospheric pressure Voltage: 230 V - 50 Hz Electrical supply: single phase + earth Connected power: 3000 W Electrical protection: II2G IIA T3 to T2 Vapour condenser: stainless steel – cooled by air (on request - version “Wx” - cooled by water in open circuit) Dimensions: cm 110 x 75 x 165...

 Open the catalog to page 2
SOLVENT RECOVERY SYSTEMS-3

SERIES STANDARD “DISTATIC” Model Explosion proof version ATEX approved For recycling of flammable and not flammable solvents Loading capacity: 120 litres Total volume of the boiler: 210 litres Inner diameter of the boiler: 500 mm Processing time: hours 4,00 - 5,30 Working temperature: 50 - 180 °C Operating: atmospheric pressure Voltage: 4000 V - 50 Hz Electrical supply: three phases + earth Connected power: 7000 W Electrical protection: II2G IIA T3 to T2 Vapour condenser: stainless steel – cooled by air (on request - version “Wx” - cooled by water in open circuit) Dimensions: Cm 130 x 91x 200...

 Open the catalog to page 3
SOLVENT RECOVERY SYSTEMS-4

SERIES STANDARD “DISTATIC” Model Explosion proof version ATEX approved For recycling of flammable and not flammable solvents Loading capacity: 160 litres Total volume of the boiler: 222 litres Inner diameter of the boiler: 500 mm Processing time: hours 4,00 - 5,30 Working temperature: 50 - 180 °C Operating: atmospheric pressure Voltage: 400 V - 50 Hz Electrical supply: three phases + earth Connected power: 11200 W Electrical protection: II2G IIA T3 to T2 Vapour condenser: stainless steel – cooled by air (on request - version “Wx” - cooled by water in open circuit) Dimensions: Cm 152 x 115 x 210...

 Open the catalog to page 4
SOLVENT RECOVERY SYSTEMS-5

ADDITIONAL “REC BAG” Bags for Distillation Residues The use of “Rec Bag” allows achieving a high concentration of solid contaminants (paints, pigments, resins, polymers, inks, etc.) with a consequent higher distillation yield. It means to get a process residue with very low solvent contents; this residue, contained inside the bag, is easy and quick to discharge, avoiding any contact with sludge and any cleaning of the boiler. RecBag 60 – 120 - 160 litres OPTIONAL Easy loading of the polluted solvent to be treated set by pushbutton with level control. Loading by Pneumatic pump or exploiting the...