Forend-Reference

Forend-Reference
1 / 12 PagesView full catalog

Forend-Reference

Product catalog summary

Document Overview: The document appears to be a technical text containing multiple sections, possibly including specifications, procedures, standards, and recommendations. However, the content is heavily corrupted or encoded, making it unreadable and preventing extraction of meaningful information.

Content Analysis:

  • No clear section headings or structured paragraphs are identifiable.
  • The text contains numerous non-standard characters, symbols, and fragmented sequences.
  • There are no discernible tables, diagrams, or graphical data to extract or summarize.
  • Due to the corrupted nature, no technical parameters, requirements, or best practices can be reliably identified or reformulated.

Conclusion: The document cannot be summarized or structured into meaningful sections due to its unreadable and corrupted format. A clean, legible version of the document is required for proper analysis and synthesis.

See more

Catalog excerpts

Forend-Reference-1

FOREND ELECTRICAL MATERIALS & FOREIGN TRADE CO, FOREND E.S.E. INSTALLATION DETAILS l-Forend E.S.E. Lightning Conductors (Forend EU, Forend EU-M, Petex-S, 7- Plastic Holders for isolated floors / roofs 8- Plastic Holders for isolated walls 11 - Forend Lightning Strike Counter 14- Earthing Rod Clamps or Exothermic Welding Connection 16- Plastic or Concrete Inspection Pits 1 7-JAM (Technical Additive Material)

 Open the catalog to page 1
Forend-Reference-2

The Details of External Lightning Protection Systems 1- E.S.E. Lightning Conductor Head Early Streamer Emission Lightning Conductor for large area protection. 2- Lightning Conductor Mast The E.S.E. Lightning Conductor height may be increased by means of an elevation mast.We recommend, Lightning Conductor Mast should be galvanized steel, is to be min. 3 m in length and 60 mm in diameter, down conductors must be fixed with 1 meter max. distance between the conductor spread along the vertical plane. 3- Down and Grounding Conductors Number of Down - Conductors Each E.S.E. Lightning Conductor should...

 Open the catalog to page 2
Forend-Reference-3

It must be a fixed mounting surface with conductor fixing internal distance is 1 m. It should be installed in such a way that its path is as direct as possible. It should be as straight as possible along the shortest path without sharp bends or upward sections. As seem figure, Where; d: safety distance, L: the length of conductor according to shock voltages the average max. value, approximately is not be a jumping danger for L < 20 d. The down conductors should not be routed along or across electrical conduits. However, when electrical conduit crossing is unavoidable, the electrical conduit should...

 Open the catalog to page 3
Forend-Reference-5

Some examples of our installations

 Open the catalog to page 5
Forend-Reference-6

Project: Academy of FC Zenit - St. Petersburg Football Junior School of Olympic Reserve in Russia

 Open the catalog to page 6
Forend-Reference-7

Some examples of our installations Project: Hospital LM de La Vega Moreno PCIA. Buenos Aires in Argentina Project: Masjid Sungai Serai in Malaysia Projea: Vayalpad Temple-TTD in India

 Open the catalog to page 7
Forend-Reference-8

Project: Residence in Shymkent Kazakhstan Project: SNO mineral water plant in Georgia Project: Kapchagay Solar Power Plant in Kazakhstan Project: National Facility thermo-electric power-station MARITZA IZTOK 2 in Bulgaria

 Open the catalog to page 8
Forend-Reference-9

Project: Telecom Tower in Ouagadougou, Burkina Faso

 Open the catalog to page 9
Forend-Reference-10

Some examples of our installations Project: Sulawmaniyah International industrial zone of Kamerik Quality Certificates I ■ -Kf-Nlj ELtKTHIK MALZEMELERI FOREHD ELEKFRlK UALZEMElERI FORENL) El.KKTRtK MAIjJESIELERl

 Open the catalog to page 10
Forend-Reference-11

Active Lightning Conductors Tester Forend active lightning conductors can be checked by a Forend LC. tester any time. Lightning Strike Counter To know you had a lightning strike!!! Currents detected from 2 kA to 100 kA Testable with 9 V battery Pivoting Mast Bases Cable Lugs Best quality and best price for your cables! wide range of products Conductor Plastic Fixing Clamps Rustproof, light, easy montage Earthing Grids The same performance but more economic and lighter than same dimension copper plates. Inspection Pits For easy resistivity control • Endurance against • Easily transportable TAM...

 Open the catalog to page 11
Forend-Reference-12

Maximum Performance Operation Voltage Power Consumption Luminous Flux (theoric) Forweld Exothermic Welding System For longer and stronger conductivity than mechanical connection Reference Countries European Union Bulgaria, Czech Republic, France, Germany, Greece, Ireland, Lithuania, Poland, Portugal, Romania, Slovakia, Eastern European And Eurasian Countries Azerbaijan, Georgia, Kazakhstan, Russian Federation, Serbia, Ukraine North America United States of America Latin America Argentina, Bolivia, Ecuador, Mexico, Peru Hong Kong, India, Indonesia, Malaysia, Philippines, Singapore, Sri Lanka,...

 Open the catalog to page 12

All Forend Lightning Protection and Earthing Co. catalogs and technical brochures

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.