Sensor systems P 2.855/2.856/2.857 * Sensor systems with permanent magnetizing yokes * Through-type testing without physical contact, with LMD, HD and LMD Therm coils* * Modular construction * Compact design Sensor system P 40 Sensor system P 40T Sensor system P 12 * LMD = Low-frequency multi-difference HD = High-frequency difference Therm coil = Test coil for material temperatures > 100 °C
Open the catalog to page 1Application * Eddy-current testing on materials which are adequately homogenized by permanent magnetization * Piece testing and continuous testing * Sensor system P 40T for material temperatures up to +400 °C * Ferrous inclusion detection in non-ferrous materials * Used in conjunction with .. FOERSTER DEFECTOMAT CS optionally with FERROMAT channel .. FOERSTER DEFECTOMAT CP/EP .. FOERSTER DEFECTOMAT DS These instruments each have their own leaflets. They can be ordered quoting the order numbers listed below. Title Part no DEFECTOMATCP/EP 165 946 4 DEFECTOMATCS 136 880 0 DEFECTOMATDS 165 655...
Open the catalog to page 2K:\VP8\2855_SensSysP\2855_Eng.vp tr.row {} td.cell {} div.block {} div.paragraph {} .font0 { font:6.00pt "Arial", sans-serif; } .font1 { font:7.00pt "Arial", sans-serif; } .font2 { font:9.00pt "Arial", sans-serif; } Construction We distinguish between three Sensor Systems on the basisoftheirdesign, i.e. in relation totheir maximum, testable material diameter or their use for cold or hot material testing. Sensor system P 12 2.855 Օ for test material temperatures up to +100 °C for test material diameters up to 12 mm Sensor system P 40 2.856 for test material temperatures up to +100 °C for...
Open the catalog to page 3TheLMDandHDcoils aremadeof encapsulated plastic. The LMD Therm coil housings are made of brass. They can be dismantled and repaired. Servicing instructions are available for therm. They are also watercooled and designed for material temperatures up to 1200 °C. If used in permanent yoke, the permitted material temperature is, however, limited to + 400 °C. Two sizes are available, whereby size I is fitted in the magnetizing yoke P 40T using a coil adapter. Coil adapter The coil adapter matches the LMD Therm coil size I for use in the magnetizing yoke 40 T. Protective guides and guide adaptors...
Open the catalog to page 4Technical data Data applicable to all three Sensor systems Test material Ferrous inclusion Eddy-current testing Non ferrous material Non ferrous, ferrous and austenitic material, only if the magnetization is adequate for homogenizing the material Test speed For virtually all production speeds occurring in practice For ferrous inclusion detection The detection limit improves with increasing test speed Permitted ambient temperature +45 °C Enclosure IP 65 2.855/2.856/2.867 - 00/12 5 * Use only clean water for industrial purposes; fit flow monitors Sensor system P 12 Sensor system P 40 Sensor...
Open the catalog to page 56 2.855/2.856/2.867 - 00/12 Fig. 3 Sensor system P 12 1.2 to 15 mm nom. Ø 0.3 to 5.6 mm nom. Ø * = LMD test coils for frequency range 1 to 100 kHz ** = HD test coils for frequency range 10 to 1000 kHz 2.899.51-1110 * 2.891.30-0012 -0150 ** 2.891.08-1003 -1056 2.855.01-1001 2.855.02-2003 -2150 0,3 to 15 nom. Ø
Open the catalog to page 68 2.855/2.856/2.867 - 00/12 Fig. 5 Sensor system P 40 1.2 to 44 mm nom. Ø 0.3 to 5.6 mm nom. Ø * = LMD Test coils for frequency range 1 to 100 kHz ** = HD Test coils for frequency range 10 to 1000 kHz 2.899.51-1110 * 2.891.30-0012 -0440 ** 2.891.08-1003 -1056 2.856.01-1001 0,3 to 15 nom. Ø 2.856.01-5100 2.855.02-2003 17 to 44 nom. Ø -2150 2.856.01-2170 -2440
Open the catalog to page 810 2.855/2.856/2.867 - 00/12 Fig. 7 Sensor system P 40T ** = LMD Therm coils, size 1 * = LMD Therm coils, size 2 Frequency range 5 to 29 nom. Ø 1 to 100 kHz > 29 nom. Ø 1 to 30 kHz 5 to 23 nom. Ø 20 to 44 nom. Ø 2.899.51-1110 ** 2.892.03-0050 -0230 2.857.01-1001 5 to 23 nom. Ø 2.857.01-5100 2.857.01-2050 -2230 20 to 44 nom. Ø 2.857.01-2200 -2440 * 2.892.03-3020 -3044 2.857.01-5200
Open the catalog to page 10Ordering instructions STANDARD COMPONENTS PERMANENT YOKE P 12 2.855.01-1001 1019120 COIL CABLE 10M, EMV 2.899.51-1110 1381610 NOZZLE, NOM.SIZE 0.3 2.855.02-2003 1315838 NOZZLE, NOM.SIZE 0.6 2.855.02-2006 1315846 NOZZLE, NOM.SIZE 1.0 2.855.02-2010 1315854 NOZZLE, NOM.SIZE 1.2 2.855.02-2012 1315862 NOZZLE, NOM.SIZE 2.0 2.855.02-2020 1315870 NOZZLE, NOM.SIZE 2.2 2.855.02-2022 1315889 NOZZLE, NOM.SIZE 2.6 2.855.02-2026 1315897 NOZZLE, NOM.SIZE 3.2 2.855.02-2032 1315757 NOZZLE, NOM.SIZE 3.6 2.855.02-2036 1315765 NOZZLE, NOM.SIZE 4.2 2.855.02-2042 1315927 NOZZLE, NOM.SIZE 4.6 2.855.02-2046...
Open the catalog to page 12LMD TEST COIL, NOM.SIZE 9 2.891.30-0090 1436686 LMD TEST COIL, NOM.SIZE 10 2.891.30-0100 1436880 LMD TEST COIL, NOM.SIZE 11 2.891.30-0110 1437038 LMD TEST COIL, NOM.SIZE 12 2.891.30-0120 1437046 LMD TEST COIL, NOM.SIZE 13 2.891.30-0130 1436694 LMD TEST COIL, NOM.SIZE 14 2.891.30-0140 1436708 LMD TEST COIL, NOM.SIZE 15 2.891.30-0150 1436716 LMD TEST COIL, NOM.SIZE 16 2.891.30-0160 1436503 LMD TEST COIL, NOM.SIZE 17 2.891.30-0170 1436724 LMD TEST COIL, NOM.SIZE 18 2.891.30-0180 1436732 LMD TEST COIL, NOM.SIZE 19 2.891.30-0190 1436740 LMD TEST COIL, NOM.SIZE 20 2.891.30-0200 1436759 LMD TEST...
Open the catalog to page 14All Foerster Instruments catalogs and technical brochures
-
STATOGRAPH® DS 6.440
12 Pages
-
DEFECTOMAT
8 Pages
Archived catalogs
-
Probe Catalog
26 Pages
-
STATOGRAPH TOUCH PROBES leaflet
14 Pages
-
MAGNATEST ECM CE leaflet
6 Pages
-
MAGNATEST ECM leaflet
6 Pages
-
Fine Wire Inspection System
1 Pages
-
MAGNATEST brochure
4 Pages
-
CIRCOFLUX brochure
6 Pages
-
CIRCOSCAN leaflet
20 Pages
-
CIRCOGRAPH DS leaflet
12 Pages
-
DEFECTOMINI leaflet
8 Pages
-
Sensor system T leaflet
15 Pages
-
Sensor system M leaflet
26 Pages
-
Sensor system H leaflet
12 Pages
-
DEFECTOMAT ECM leaflet
6 Pages
-
DEFECTOMAT DI brochure
4 Pages
-
DEFECTOMAT CI brochure
4 Pages
-
DEFECTOMAT DS
14 Pages