Tunnel Light VL-TNL Series

Tunnel Light VL-TNL Series

Tunnel Light VL-TNL Series

Product catalog summary
Intended Use
The VL-TNL Series Tunnel Light is designed for industrial applications such as part inspection, positioning, color checking, code reading, and quality inspection. It must be operated within specified technical limits and installed according to instructions to ensure safety and prevent damage.

Technical Information
The product range includes models with different dimensions and specifications, such as wavelength (625nm for red and 6500K for white), power supply (24VDC), and power consumption. All models have an IP50 rating, with an option for IP67.

Dimensions / Installation
Installation requires knowledge of assembly instructions. Safety symbols are detailed in the manual's safety section.

Electrical Connection
The lights can operate in continuous or strobe modes, with various intensity settings controlled by dip switches. High-intensity modes should only be used with strobe input.

Faults
If LEDs do not light up, check connections and power supply. Contact FÖGE or a distributor if issues persist.

Warnings
Ensure power supply and devices are connected according to safety regulations. Avoid exceeding voltage limits and protect the sensor from shocks.

Safety
Familiarity with assembly instructions is assumed. Symbols indicate potential hazards, property damage, and electrical shock risks.

Liability for Material Defects
FÖGE provides a 12-month liability for material defects from delivery. Defective parts will be repaired or replaced if returned prepaid. Damage from improper handling or unauthorized repairs is not covered.

Decommissioning, Disposal
Remove power and output cables before disposal. Follow local regulations for waste treatment and disposal to prevent environmental harm.
See more

Catalog excerpts

Tunnel Light VL-TNL Series-1

www.fogegmbh.com [email protected] FÖGE ELEKTRONIK GMBH Böhleswasenweg 11 72555 Metzingen +49 7123 9570508 Instruction Manual Product: VL-TNL Series Tunnel Light

 Open the catalog to page 1
Tunnel Light VL-TNL Series-2

1. Intended Use VL-TNL Series Tunnel Light is designed for use in industrial areas. Purpose of the product is inspection of parts, positioning, color check, code reading, quality inspection. Light is positioned above the part. The system must be operated within the limits specified in technical data and used according to technical specifications as well as installation instructions. The system must be used in such a way that no person are in danger or machines and other material goods are damaged in the event of malfunction or total failure of the system. Take additional precautions for safety...

 Open the catalog to page 2
Tunnel Light VL-TNL Series-3

3. Dimensions / Installation System operation assumes knowledge of the assembly instructions. The symbols used for safety is shown in section 8(Safety) of manual. Accessories Suitable Product Accessories Image Ordering Code Solar panel inspection, large area positioning Shiny surface inspection Part mark read with diffuse lighting Shiny part positioning, inspection

 Open the catalog to page 3
Tunnel Light VL-TNL Series-4

5. Display/Controls Illumination intensity modes with dip switches With dip swithes located on the product, you can increase the light intensity when it is needed. Light ON Position Percentage Light Intensity Accessories Image ON : % 100 OFF : % 0 (Standard High Intensity) Can be used without strobe, continuous illumination mode Due to high illumination settings, use this mode only with strobe input with given ON/OFF percentage. Due to high illumination settings, use this mode only with strobe input with given ON/OFF percentage. Due to high illumination settings, use this mode only with strobe...

 Open the catalog to page 4
Tunnel Light VL-TNL Series-5

6. Faults In any case do not open the product. If the leds not on check the connection and power supply. If still leds are not on contact FÖGE or distributor. 7. Warnings • Connect the power supply and the display/output device according to the safety regulations for electrical equipment. • The supply voltage must not exceed the specified limits. • Avoid shocks and impacts to the sensor. • Protect the cable against damage. Possible Results of Avoidance Risk of injury by electric shock Damage to or destruction of the sensor

 Open the catalog to page 5
Tunnel Light VL-TNL Series-6

8. Safety System operation assumes knowledge of the assembly instructions. The following symbols are used in these assembly instructions: Indicates a hazardous situation which, if not avoided, may result in minor or moderate injury. Indicates a situation that may result in property damage if not avoided. Indicates an electrical shock if not avoided or properly follow comments. 9.Liability for Material Defects All components of the device have been checked and tested for functionality at the production facility. However, if defects occur despite our careful quality control, FÖGE or your dealer...

 Open the catalog to page 6