The SE-DCX-110 Series pulsedDC Antistatic Bar by FÖGE ELEKTRONIK GMBH is designed for industrial use to neutralize static charges on non-conductive materials like plastic, glass, and fabric. It utilizes tungsten emitter pins to produce ions that eliminate static electricity, which can cause quality and safety issues. The pulsedDC method is more effective than AC for long-range and high-charge applications.
Installation Guidelines
When assembling ionisers without air, ensure the emitter direction faces the part to be neutralized. A tilt of up to 45 degrees is acceptable, but exceeding this angle negatively affects ionization. Avoid covering the ioniser with metal or placing metal near the emitter pins. For ionisers with air, the air direction should also face the part, with a nozzle-emitter angle between 45 and 90 degrees.
Technical Specifications
The system must operate within specified technical limits and installation instructions to prevent danger to people or damage to machines. Fast models (SE-DCF) can be mounted up to 200mm from the surface, while Long models (SE-DCL) can be mounted up to 700mm.
Electrical Connection
Connect the power supply and display/output device according to safety regulations. The input voltage should be between 21V and 28V. If the status LED indicates an issue, check the input voltage, clean the bar, and ensure proper positioning. For faults, do not open the product; instead, contact FÖGE or a distributor.
Maintenance
Regular cleaning of the ionising bars is necessary due to particle accumulation on emitter pins, which affects performance. Use FÖGE Antistatic Bar Cleaning Liquids and Brushes for maintenance.
Safety and Liability
Follow assembly instructions and safety symbols to avoid injury or damage. The liability for material defects is 12 months from delivery, covering repairs or replacements for defects not caused by improper handling or unauthorized modifications.
Decommissioning and Disposal
Remove power supply and output cables before disposal. Comply with local waste treatment and disposal regulations to prevent environmental harm.
See more

Catalog excerpts

pulsedDC Antistatic Bar SE-DCX-110 Series-1

www.fogegmbh.com [email protected] FÖGE ELEKTRONIK GMBH Böhleswasenweg 11 72555 Metzingen +49 7123 9570508 Instruction Manual Product: SE-DCX-110 Series pulsedDC Antistatic Bar

 Open the catalog to page 1
pulsedDC Antistatic Bar SE-DCX-110 Series-2

IMPORTANT Attention: When assembling ionisers without air, always emitter direction should look towards the part. Tilt mounting up to 45 degrees would be ok but be informed that higher than this angle will effect ionisation in negative way. Emitter Emitter Direction Mounting bracket can be metal or any other material Mounting distance varies according to the antistatic product, check specifications Up to 45 degree angle is applicable, more than this tilting angle of the part effects negative on ionisation Attention: Do not cover the ioniser with metal or attach metal close to the emitter pins...

 Open the catalog to page 2
pulsedDC Antistatic Bar SE-DCX-110 Series-3

IMPORTANT Attention: When assembling ionisers with air, always air direction should look towards the part. Tilt mounting up to 45 degrees would be ok but be informed that higher than this angle will effect ionisation in negative way. Part to be neutralized Nozzle – emitter angle 45 – 90 degrees. Mounting bracket can be metal or any other material Mounting distance varies according to the antistatic product, check specifications Up to 45 degree angle is applicable, more than this tilting angle of the part effects negative on ionisation Attention: Do not cover the ioniser with metal or attach metal...

 Open the catalog to page 3
pulsedDC Antistatic Bar SE-DCX-110 Series-4

1. Intended Use SE-DC Series Antistatic Bar is designed for use in industrial areas. Purpose of the product is neutralizing charged plastic, glass, fabric or any parts which are not conductive. Negative and positive ions produced by tungsten emitter pins which will ionize the part and eliminate static electricity which causes quality and safety problems. PulsedDC method is more effective and powerful according to AC which makes these products are ideal for long range and high charges. The system must be operated within the limits specified in technical data and used according to technical specifications...

 Open the catalog to page 4
pulsedDC Antistatic Bar SE-DCX-110 Series-5

3. Dimensions / Installation System operation assumes knowledge of the assembly instructions. The symbols used for safety is shown in section 8(Safety) of manual. ATTN: Fast(SE-DCF) models can be connected up to 200mm from the surface for maximum static elimination and Long(SE-DCL) models can be connected up to 700mm.

 Open the catalog to page 5
pulsedDC Antistatic Bar SE-DCX-110 Series-6

1: 24V (Brown) 2: Earth (White) The WHITE wire to the M8 4-pin connector must be connected to installation earth. 3: 0V & Earth (Blue) 4: Remote Monitor (Black) • Input voltage is outside of 21V - 28V range. • Check input voltage at Bar. • Bar overloaded. • Clean Bar. • Make sure that positioning of Bar meets these instructions. • H.V. output not correct. • Contact FÖGE or distributor.

 Open the catalog to page 6
pulsedDC Antistatic Bar SE-DCX-110 Series-7

6. Faults In any of below cases or others do not open the product. If switch is on but the ON/OFF light is OFF, change the fuse inside the power unit. Fuse type: F0.5AL250V Fast Blow Glass Fuse 5x20mm 7. Warnings Connect the power supply and the display/output device according to the safety regulations for electrical equipment. The supply voltage must not exceed the specified limits. Avoid shocks and impacts to the sensor. Protect the cable against damage. Possible Results of Avoidance Risk of injury by electric shock Damage to or destruction of the sensor 8. Maintanence Because of the nature...

 Open the catalog to page 7
pulsedDC Antistatic Bar SE-DCX-110 Series-8

9. Safety System operation assumes knowledge of the assembly instructions. The following symbols are used in these assembly instructions: Indicates a hazardous situation which, if not avoided, may result in minor or moderate injury. Indicates a situation that may result in property damage if not avoided. Indicates an electrical shock if not avoided or properly follow comments. 10.Liability for Material Defects All components of the device have been checked and tested for functionality at the production facility. However, if defects occur despite our careful quality control, FÖGE or your dealer...