Low Angle Light VL-DFF Series
6Pages

{{requestButtons}}

Catalog excerpts

Low Angle Light VL-DFF Series - 1

www.fogegmbh.com info@fogegmbh.com FÖGE ELEKTRONIK GMBH Böhleswasenweg 11 72555 Metzingen +49 7123 9570508 Instruction Manual Product: VL-DFF Series Low Angle Light

Open the catalog to page 1
Low Angle Light VL-DFF Series - 2

1. Intended Use VL-DFF Series Low Angle Light is designed for use in industrial areas. Purpose of the product is inspection of parts, positioning for large parts. Light is positioned as close as possible to the part. The system must be operated within the limits specified in technical data and used according to technical specifications as well as installation instructions. The system must be used in such a way that no person are in danger or machines and other material goods are damaged in the event of malfunction or total failure of the system. Take additional precautions for safety and...

Open the catalog to page 2
Low Angle Light VL-DFF Series - 3

3. Dimensions / Installation System operation assumes knowledge of the assembly instructions. The symbols used for safety is shown in section 8(Safety) of manual. Ordering Code Accessories Image Detecting edges, edge defect detection, positioning of low contrast parts Ball bearing inspection, round object check Positionin based on edges, low color contrast part identification Part edge crack, dent inspection Groove, scratch detection, diameter measurement based on edges Part detection on PCB’s, positioning, detecting parts based on height difference Part positionin related to the edges, part...

Open the catalog to page 3
Low Angle Light VL-DFF Series - 4

5. Display/Controls Illumination intensity modes with dip switches With dip swithes located on the product, you can increase the light intensity when it is needed. Light ON Position Percentage Light Intensity Accessories Image ON : % 100 OFF : % 0 (Standard High Intensity) Can be used without strobe, continuous illumination mode Due to high illumination settings, use this mode only with strobe input with given ON/OFF percentage. Due to high illumination settings, use this mode only with strobe input with given ON/OFF percentage. Due to high illumination settings, use this mode only with...

Open the catalog to page 4
Low Angle Light VL-DFF Series - 5

6. Faults In any case do not open the product. If the leds not on check the connection and power supply. If still leds are not on contact FÖGE or distributor. 7. Warnings • Connect the power supply and the display/output device according to the safety regulations for electrical equipment. • The supply voltage must not exceed the specified limits. • Avoid shocks and impacts to the sensor. • Protect the cable against damage. Possible Results of Avoidance Risk of injury by electric shock Damage to or destruction of the sensor

Open the catalog to page 5
Low Angle Light VL-DFF Series - 6

8. Safety System operation assumes knowledge of the assembly instructions. The following symbols are used in these assembly instructions: Indicates a hazardous situation which, if not avoided, may result in minor or moderate injury. Indicates a situation that may result in property damage if not avoided. Indicates an electrical shock if not avoided or properly follow comments. 9.Liability for Material Defects All components of the device have been checked and tested for functionality at the production facility. However, if defects occur despite our careful quality control, FÖGE or your...

Open the catalog to page 6