Catalog excerpts
www.fogegmbh.com info@fogegmbh.com FÖGE ELEKTRONIK GMBH Böhleswasenweg 11 72555 Metzingen +49 7123 9570508 Instruction Manual Product: SE-BLC Series Compact Antistatic Blower
Open the catalog to page 1IMPORTANT Attention: When assembling ionisers without air, always emitter direction should look towards the part. Tilt mounting up to 45 degrees would be ok but be informed that higher than this angle will effect ionisation in negative way. Emitter Emitter Direction Mounting bracket can be metal or any other material Mounting distance varies according to the antistatic product, check specifications Up to 45 degree angle is applicable, more than this tilting angle of the part effects negative on ionisation Attention: Do not cover the ioniser with metal or attach metal close to the emitter...
Open the catalog to page 2IMPORTANT Attention: When assembling ionisers with air, always air direction should look towards the part. Tilt mounting up to 45 degrees would be ok but be informed that higher than this angle will effect ionisation in negative way. Part to be neutralized Nozzle – emitter angle 45 – 90 degrees. Mounting bracket can be metal or any other material Mounting distance varies according to the antistatic product, check specifications Up to 45 degree angle is applicable, more than this tilting angle of the part effects negative on ionisation Attention: Do not cover the ioniser with metal or attach...
Open the catalog to page 31. Intended Use SE-BLC Series Compact Antistatic Blower is designed for use in industrial areas. Purpose of the product is neutralizing the charged plastic, glass, fabric or any parts which are not conductive. Airflow from the ionizer will carry negative and positive ions which will ionize the part and eliminate static electricity which causes quality and safety problems. The system must be operated within the limits specified in technical data and used according to technical specifications as well as installation instructions. The system must be used in such a way that no person are in...
Open the catalog to page 43. Dimensions / Installation System operation assumes knowledge of the assembly instructions. The symbols used for safety is shown in section 8(Safety) of manual. Air blow direction should be towards the charged parts within 700mm distance to neutralize the part highest effectiveness.
Open the catalog to page 55.1. Displays/Indicators • Fan Fault • Ionisation Fault • Fan Speed Indicator LEDs • 24V supply • Ionisation ON 5.2. Controls • ON/OFF Switch(Ionisation) • Fan Speed Adjustment
Open the catalog to page 66. Faults In any of below cases or others do not open the product. 24V supply indicator LED 24VDC Power supply missing, check cable, connector or power supply. Power supply OK. Ionisation ON indicator LED Ionisation OK Checking device condition at start or ionization is OFF cause of fan or HV power unit. Fan Fault: LED Fan OK Fan is not working, contact FÖGE. Fan is not working, make an eye check. If there is a part stuck inside fan, cut off the power to the device and remove the stuck part. Otherwise contact FÖGE. Ionisation Fault Ionisation OK Ionisation power unit is not working, make an...
Open the catalog to page 79. Safety System operation assumes knowledge of the assembly instructions. The following symbols are used in these assembly instructions: Indicates a hazardous situation which, if not avoided, may result in minor or moderate injury. Indicates a situation that may result in property damage if not avoided. Indicates an electrical shock if not avoided or properly follow comments. 10.Liability for Material Defects All components of the device have been checked and tested for functionality at the production facility. However, if defects occur despite our careful quality control, FÖGE or your...
Open the catalog to page 8All FÖGE Elektronik GmbH catalogs and technical brochures
-
Antistatic Products Catalogue
24 Pages
-
Tunnel Light VL-TNL Series
6 Pages
-
Ring Light VL-RGF Series
6 Pages
-
Dome Light VL-DOM Series
6 Pages
-
Coaxial Light VL-COX Series
6 Pages
-
Bar Light VL-BAR Series
6 Pages
-
Long Bar Light VL-BAL Series
6 Pages