1. Intended Use
The SE-BLC Series Compact Antistatic Blower is designed for industrial use to neutralize static charges on non-conductive materials like plastic, glass, and fabric. It operates by emitting ions to eliminate static electricity, which can cause quality and safety issues. The system must be used within specified technical limits and installation instructions to prevent danger to people or damage to equipment.
2. Technical Information
Operating conditions include a temperature range of 0-60°C and a maximum relative humidity of 70%. The blower requires a 24V DC power supply via an M12 connector, with a maximum power consumption of 9W.
3. Installation
Proper installation requires knowledge of assembly instructions. The ionizer should be directed towards the charged parts within a 700mm distance for optimal effectiveness. The mounting angle should not exceed 45 degrees to maintain ionization efficiency.
4. Electrical Connection
Connect the power supply and display/output devices according to safety regulations. Ensure the supply voltage does not exceed specified limits and protect cables from damage.
5. Display/Controls
The device includes indicators for fan and ionization faults, fan speed, and power supply status. Controls include an ON/OFF switch for ionization and fan speed adjustment.
6. Faults
Indicators will show if there are issues with the fan or ionization. If faults occur, do not open the product; instead, contact FÖGE for assistance.
7. Warnings
Avoid covering the ionizer with metal or placing metal near the emitter pins, as this can hinder ionization. Ensure no metal is behind the part to be ionized.
8. Maintenance
Regular cleaning of the emitter pins is necessary due to particle accumulation, which can affect performance. Use FÖGE Antistatic Bar Cleaning Liquids and Brushes for maintenance.
9. Safety
Follow assembly instructions and heed safety symbols to prevent injury or equipment damage.
10. Liability for Material Defects
FÖGE offers a 12-month warranty from delivery for material defects, excluding wear and tear. Repairs are conducted by FÖGE, and improper handling voids the warranty.
11. Decommissioning, Disposal
Remove power supply and cables before disposal. Follow local regulations for waste treatment and disposal to avoid environmental harm.
See more

Catalog excerpts

Compact Antistatic Blower SE-BLC Series-1

www.fogegmbh.com [email protected] FÖGE ELEKTRONIK GMBH Böhleswasenweg 11 72555 Metzingen +49 7123 9570508 Instruction Manual Product: SE-BLC Series Compact Antistatic Blower

 Open the catalog to page 1
Compact Antistatic Blower SE-BLC Series-2

IMPORTANT Attention: When assembling ionisers without air, always emitter direction should look towards the part. Tilt mounting up to 45 degrees would be ok but be informed that higher than this angle will effect ionisation in negative way. Emitter Emitter Direction Mounting bracket can be metal or any other material Mounting distance varies according to the antistatic product, check specifications Up to 45 degree angle is applicable, more than this tilting angle of the part effects negative on ionisation Attention: Do not cover the ioniser with metal or attach metal close to the emitter pins...

 Open the catalog to page 2
Compact Antistatic Blower SE-BLC Series-3

IMPORTANT Attention: When assembling ionisers with air, always air direction should look towards the part. Tilt mounting up to 45 degrees would be ok but be informed that higher than this angle will effect ionisation in negative way. Part to be neutralized Nozzle – emitter angle 45 – 90 degrees. Mounting bracket can be metal or any other material Mounting distance varies according to the antistatic product, check specifications Up to 45 degree angle is applicable, more than this tilting angle of the part effects negative on ionisation Attention: Do not cover the ioniser with metal or attach metal...

 Open the catalog to page 3
Compact Antistatic Blower SE-BLC Series-4

1. Intended Use SE-BLC Series Compact Antistatic Blower is designed for use in industrial areas. Purpose of the product is neutralizing the charged plastic, glass, fabric or any parts which are not conductive. Airflow from the ionizer will carry negative and positive ions which will ionize the part and eliminate static electricity which causes quality and safety problems. The system must be operated within the limits specified in technical data and used according to technical specifications as well as installation instructions. The system must be used in such a way that no person are in danger...

 Open the catalog to page 4
Compact Antistatic Blower SE-BLC Series-5

3. Dimensions / Installation System operation assumes knowledge of the assembly instructions. The symbols used for safety is shown in section 8(Safety) of manual. Air blow direction should be towards the charged parts within 700mm distance to neutralize the part highest effectiveness.

 Open the catalog to page 5
Compact Antistatic Blower SE-BLC Series-6

5.1. Displays/Indicators • Fan Fault • Ionisation Fault • Fan Speed Indicator LEDs • 24V supply • Ionisation ON 5.2. Controls • ON/OFF Switch(Ionisation) • Fan Speed Adjustment

 Open the catalog to page 6
Compact Antistatic Blower SE-BLC Series-7

6. Faults In any of below cases or others do not open the product. 24V supply indicator LED 24VDC Power supply missing, check cable, connector or power supply. Power supply OK. Ionisation ON indicator LED Ionisation OK Checking device condition at start or ionization is OFF cause of fan or HV power unit. Fan Fault: LED Fan OK Fan is not working, contact FÖGE. Fan is not working, make an eye check. If there is a part stuck inside fan, cut off the power to the device and remove the stuck part. Otherwise contact FÖGE. Ionisation Fault Ionisation OK Ionisation power unit is not working, make an eye...

 Open the catalog to page 7
Compact Antistatic Blower SE-BLC Series-8

9. Safety System operation assumes knowledge of the assembly instructions. The following symbols are used in these assembly instructions: Indicates a hazardous situation which, if not avoided, may result in minor or moderate injury. Indicates a situation that may result in property damage if not avoided. Indicates an electrical shock if not avoided or properly follow comments. 10.Liability for Material Defects All components of the device have been checked and tested for functionality at the production facility. However, if defects occur despite our careful quality control, FÖGE or your dealer...