1. Intended Use
The SE-ACB Series Antistatic Bar is designed for industrial use to neutralize and clean charged non-conductive materials like plastic, glass, and fabric. It operates by producing ions through stainless steel emitter pins to eliminate static electricity, which can cause quality and safety issues. The system must be used within specified technical limits and installation instructions to prevent danger to people or damage to machines and materials.
2. Technical Information
The SE-PAC-55-4-C and SE-PAC-55-2-C models come with a 3m HFFR protected HV connector, extendable up to 10m. The maximum total length of cables and bars should not exceed 15m to ensure proper operation of the power unit.
3. Dimensions / Installation
Installation requires knowledge of assembly instructions. The maximum cable and bar length is 15m. Exceeding this length may cause the power unit to malfunction.
4. Electrical Connection
Connect the Antistatic Bar using metal screw-type HV connectors. An additional earth connection is recommended. The system uses a 220V AC 50Hz plug connection with an ON/OFF switch. A fast blow glass fuse (F0.5AL250V) is used for protection.
5. Faults
If the ON/OFF light is off despite the switch being on, replace the fuse. Do not open the product in case of faults.
6. Warnings
Ensure the supply voltage does not exceed specified limits. Protect cables from damage and avoid shocks to the sensor.
7. Maintenance
Regular cleaning of ionizing bars is necessary as particles can stick to emitter pins, affecting performance. Use FÖGE cleaning liquids and brushes.
8. Safety
Familiarity with assembly instructions is assumed. Symbols indicate potential hazards, property damage, and electrical shock risks.
9. Liability for Material Defects
FÖGE offers a 12-month liability for material defects from delivery. Defective parts will be repaired or replaced if returned with prepaid shipping. Damage from improper handling or unauthorized repairs is not covered.
10. Decommissioning, Disposal
Remove power supply and cables before disposal. Follow country-specific waste regulations to avoid environmental harm.
See more

Catalog excerpts

AC Static Eliminator with Rotary Air Nozzle SE-ARN Series-1

www.fogegmbh.com [email protected] FÖGE ELEKTRONIK GMBH Böhleswasenweg 11 72555 Metzingen +49 7123 9570508 Instruction Manual Product: SE-ARN Series AC Static Eliminator with Rotary Air Nozzle P1

 Open the catalog to page 1
AC Static Eliminator with Rotary Air Nozzle SE-ARN Series-2

IMPORTANT Attention: When assembling ionisers without air, always emitter direction should look towards the part. Tilt mounting up to 45 degrees would be ok but be informed that higher than this angle will effect ionisation in negative way. Emitter Emitter Direction Mounting bracket can be metal or any other material Mounting distance varies according to the antistatic product, check specifications Up to 45 degree angle is applicable, more than this tilting angle of the part effects negative on ionisation Attention: Do not cover the ioniser with metal or attach metal close to the emitter pins...

 Open the catalog to page 2
AC Static Eliminator with Rotary Air Nozzle SE-ARN Series-3

IMPORTANT Attention: When assembling ionisers with air, always air direction should look towards the part. Tilt mounting up to 45 degrees would be ok but be informed that higher than this angle will effect ionisation in negative way. Part to be neutralized Nozzle – emitter angle 45 – 90 degrees. Mounting bracket can be metal or any other material Mounting distance varies according to the antistatic product, check specifications Up to 45 degree angle is applicable, more than this tilting angle of the part effects negative on ionisation Attention: Do not cover the ioniser with metal or attach metal...

 Open the catalog to page 3
AC Static Eliminator with Rotary Air Nozzle SE-ARN Series-4

1. Intended Use SE-ACB Series Antistatic Bar is designed for use in industrial areas. Purpose of the product is neutralizing and cleaning the charged plastic, glass, fabric or any parts which are not conductive. Negative and positive ions produced by stainless steel emitter pins will ionize the part and eliminate static electricity which causes quality and safety problems. The system must be operated within the limits specified in technical data and used according to technical specifications as well as installation instructions. The system must be used in such a way that no person are in danger...

 Open the catalog to page 4
AC Static Eliminator with Rotary Air Nozzle SE-ARN Series-5

3. Dimensions / Installation System operation assumes knowledge of the assembly instructions. The symbols used for safety is shown in section 8(Safety) of manual. SE-CAB-AC-1: Non standard option 1mt cable can be ordered up to 15mt. For all models, maximum length of cable and bars connected(total) can be used is 15m. If length of cables and bars exceed 15m. Power unit will not work properly and may cut the power to prevent damage.

 Open the catalog to page 5
AC Static Eliminator with Rotary Air Nozzle SE-ARN Series-6

4.Electrical Connection Additional Earth Connection (Recommended to connect separately) Fuse Cap F0.5AL250V Fast Blow Glass Fuse 5x20mm Connect Antistatic Bar with Metal Screw Type HV Connectors which FÖGE bars have as a connection. 5.2. Controls • ON/OFF Switch

 Open the catalog to page 6
AC Static Eliminator with Rotary Air Nozzle SE-ARN Series-7

6. Faults In any of below cases or others do not open the product. If switch is on but the ON/OFF light is OFF, change the fuse inside the power unit. Fuse type: F0.5AL250V Fast Blow Glass Fuse 5x20mm 7. Warnings Connect the power supply and the display/output device according to the safety regulations for electrical equipment. The supply voltage must not exceed the specified limits. Avoid shocks and impacts to the sensor. Protect the cable against damage. Possible Results of Avoidance Risk of injury by electric shock Damage to or destruction of the sensor 8. Maintanence Because of the nature...

 Open the catalog to page 7
AC Static Eliminator with Rotary Air Nozzle SE-ARN Series-8

9. Safety System operation assumes knowledge of the assembly instructions. The following symbols are used in these assembly instructions: Indicates a hazardous situation which, if not avoided, may result in minor or moderate injury. Indicates a situation that may result in property damage if not avoided. Indicates an electrical shock if not avoided or properly follow comments. 10.Liability for Material Defects All components of the device have been checked and tested for functionality at the production facility. However, if defects occur despite our careful quality control, FÖGE or your dealer...

 Open the catalog to page 8