Catalog excerpts
F#GEIndustrial Equipments P www.fogegmbh.com info@fogegmbh.com ft FOGE ELEKTRONIK GMBH Presentstr. 3, 63939 Worth am Main □ +49 9372 9809477 Instruction Manual Product: SE-ACG Series AC Antistatic Airgun
Open the catalog to page 1Attention: When assembling ionisers without air, always emitter direction should look towards the part. Tilt mounting up to 45 degrees would be ok but be informed that higher than this angle will effect ionisation in negative way. Mounting distance varies according to the antistatic product, check specifications Mounting bracket can be metal or any other material Up to 45 degree angle is applicable, more than this tilting angle of the part effects negative on ionisation Attention: Do not cover the ioniser with metal or attach metal close to the emitter pins of the ionisers. Attention: Never...
Open the catalog to page 2IMPORTANT Attention: When assembling ionisers with air, always air direction should look towards the part. Tilt mounting up to 45 degrees would be ok but be informed that higher than this angle will effect ionisation in negative way. Part to be neutralized Nozzle – emitter angle 45 – 90 degrees. Mounting bracket can be metal or any other material Mounting distance varies according to the antistatic product, check specifications Up to 45 degree angle is applicable, more than this tilting angle of the part effects negative on ionisation Attention: Do not cover the ioniser with metal or attach...
Open the catalog to page 3SE-ACG Series Antistatic Airgun is designed for use in industrial areas. Purpose of the product is neutralizing and cleaning the charged plastic, glass, fabric or any parts which are not conductive. Airflow from the ionizer will carry negative and positive ions which will ionize the part and eliminate static electricity which causes quality and safety problems. High velocity air from nozzle cleans the surface. Rotary type nozzle cleans even better than standard nozzle because of pulsation effect. The system must be operated within the limits specified in technical data and used according to...
Open the catalog to page 4Magnetic mounting bracket for air gun Ionizing ring Air gun body R&L Mechanical trigger HP connector set Rotary nozzle for air gun Protective cap Non rotating standard nozzle for air gun Non rotating standard nozzle for air gun (3mm diameter)
Open the catalog to page 54. Dimensions / Installation System operation assumes knowledge of the assembly instructions. The symbols used for safety is shown in section 10(Safety) of manual. 41,5 SE-CAB-AC-1: Non standard option 1mt cable can be ordered up to 12 mt Please note that you must subtract the length of the antistatic bars from the total length, i.e. for power supply with 5.5 kV the total length of antistatic bar and cable must not exceed 12m and for power supply with 8 kV the total length of antistatic bar and cable must not exceed 25m. If the total permissible length is exceeded, the power supply unit may...
Open the catalog to page 65.Electrical Connection Additional Earth Connection (Recommended to connect separately) Fuse Cap F0.5AL250V Fast Blow Glass Fuse 5x20mm Connect Antistatic Bar with Metal Screw Type HV Connectors which FÖGE bars have as a connection. 6.2. Controls • ON/OFF Switch
Open the catalog to page 77. Faults In any of below cases or others do not open the product. If switch is on but the ON/OFF light is OFF, change the fuse inside the power unit. Fuse type: F0.5AL250V Fast Blow Glass Fuse 5x20mm 8. Warnings Connect the power supply and the display/output device according to the safety regulations for electrical equipment. The supply voltage must not exceed the specified limits. Avoid shocks and impacts to the sensor. Protect the cable against damage. Possible Results of Avoidance Risk of injury by electric shock Damage to or destruction of the sensor 9. Maintanence Because of the...
Open the catalog to page 810. Safety System operation assumes knowledge of the assembly instructions. The following symbols are used in these assembly instructions: Indicates a hazardous situation which, if not avoided, may result in minor or moderate injury. Indicates a situation that may result in property damage if not avoided. Indicates an electrical shock if not avoided or properly follow comments. 11.Liability for Material Defects All components of the device have been checked and tested for functionality at the production facility. However, if defects occur despite our careful quality control, FÖGE or your...
Open the catalog to page 9All FÖGE Elektronik GmbH catalogs and technical brochures
-
Antistatic Products Catalogue
24 Pages
-
Tunnel Light VL-TNL Series
6 Pages
-
Ring Light VL-RGF Series
6 Pages
-
Dome Light VL-DOM Series
6 Pages
-
Coaxial Light VL-COX Series
6 Pages
-
Bar Light VL-BAR Series
6 Pages
-
Long Bar Light VL-BAL Series
6 Pages