FPI AQMS-1000 Ambient air quality monitoring system
12Pages

{{requestButtons}}

Catalog excerpts

FPI AQMS-1000 Ambient air quality monitoring system - 1

Air Quality Monitoring System For more information visit our website at www.fpi-inc.com/en © Focused Photonics Inc. All right reserved. All trademarks are the property of Focused Photonics Inc. and its subsidiaries. Specifications, terms and pricing are subject to change. Focused Photonics (Hangzhou) Inc. No. 459, Qianmo Road, Binjiang District, Hangzhou, China Tel: +86 571 8501 2188

Open the catalog to page 1
FPI AQMS-1000 Ambient air quality monitoring system - 2

AQMS-500 Sulfur Dioxide Analyzer Air Quality Monitoring System - Principle - Features - Data Storage and Analysis - Removal of Interferences - Technical Data AQMS-550 Hydrogen Sulfide Analyzer - Principle - Features - Technical Data AQMS-600 Nitrogen Oxides Analyzer - Principle - Water Removal System - HC/CO/NO Scrubber - Technical Data - Ozone Generation - Technical Data - Technical Data - Technical Data BPM-200 Continuous Particulate Monitor - Ozone Scrubber - Ozone Photometer - Data Storage and Analysis - Technical Data - Technical Data AQMS-400 Carbon Monoxide Analyzer - Full Heated...

Open the catalog to page 2
FPI AQMS-1000 Ambient air quality monitoring system - 3

Features • Ultra high purity zero air output; FPI AQMS-100 provides ultra pure pollutant-free zero air for calibrating zero point of ambient air quality monitor.It consists of air compressing and cooling system, water removal system, gaseous pollutant scrubber • Integrated dew point sensor; • Regenerative dryer utilizing molecular sieve • High performance scrubbers to remove hydrocarbon, CO, SO2, NH3, to perform maintenance free advantage; • Remote display and configuration on key functions; system, particle removal and zero gas output system. Technical Data Principle The AQMS-100 generates...

Open the catalog to page 3
FPI AQMS-1000 Ambient air quality monitoring system - 4

AQMS-200 Dynamic Calibrator FPI AQMS-200 dynamic dilution calibrator utilizes two mass flow controllers to perform standard zero and span calibration with up Technical Data Dilution System Dilution Gas Flow Range Standard Gas Flow Range Flow Accuracy Diluent Gas Input Ports 1 Ozone Generator (Optional) • Stable trace level ozone output down to 0.1ppm; • Optional ozone generator, gas phase titration and photometer for independent ozone calibration; • User selectable output include RS232 and ethernet; Response Time Mass Flow Controller Rise / Fall Time linearized output; Range Linearity •...

Open the catalog to page 4
FPI AQMS-1000 Ambient air quality monitoring system - 5

Ozone Photometer Data Storage and Analysis In ozone photometer, a mercury lamp is used Stored data are easily retrievable through as light source, from which light beam travels the serial or Ethernet port via PC through two window glasses and, a gas chamber, clientsoftware, allowing operators to FPI AQMS-300 Ozone analyzer measures to reach a sensor to convert the light into electric perform predictive diagnostics and ambient O3 concentration in ppb level by signal.Temperature control circuit, heating device enhanced data analysis by tracking utilizing UV photometric absorption technology....

Open the catalog to page 5
FPI AQMS-1000 Ambient air quality monitoring system - 6

AQMS-400 Carbon Monoxide Analyzer Data Storage and Analysis FPI AQMS-400 carbon monoxide (CO) analyzer measures ambient parameter trends. Stored data are easily retrievable through the serial or ethernet port via PC client software, allowing operators to perform predictive diagnostics and enhanced data analysis by tracking CO concentration by employing nondispersive infrared with gas filter correlation method technology. GFC The Gas Filter Correlation (GFC) adopts Non-dispersive infrared technology and includes two units, one for reference Infrared energy emitted by light source is...

Open the catalog to page 6
FPI AQMS-1000 Ambient air quality monitoring system - 7

AQMS-500 Sulfur Dioxide Analyzer The permeation scrubber acting as hydrocarbon FPI AQMS-500 sulfur dioxide (SO2) analyzer applies UV fluorescence kicker removes aromatic hydrocarbon such as technology with photomultiplier tube (PMT) to measure SO2. xylene and naphthalene which causes interference. tube and converted into an electrical Optical filtering are employed to improve the signal. The number of electrons is rejection of interference from high nitrogen oxides. system and the current or voltage is the characteristic fluorescence released by SO2 in an ambient air sample contained in the...

Open the catalog to page 7
FPI AQMS-1000 Ambient air quality monitoring system - 8

Pressure Sensor Exhaust Flow Sensor AQMS-550 H2S analyzer adopts UV fluorescence principle with an internal thermal catalytic converter to measure H2S in ambient air at levels commonly required. Span/Zero Hydrocarbon Removal Tube Module AQMS-550 is equipped with an internally mounted catalytic converter set at 315°C to convert H2S to SO2. By passing the sample through a SO2 scrubber which removes any SO2, the H2S is converted to SO2 using this Technical Data internal H2S converter and measured using the pulsed fluorescence technique. Measurement Units ppb, ppm, μg/m³, mg/m³ (selectable)...

Open the catalog to page 8
FPI AQMS-1000 Ambient air quality monitoring system - 9

AQMS-600 Nitrogen Oxides Analyzer Ozone Generation The characteristic fluorescence of unstable Permeation dryer are introduced in ozone generation to provide long system durability photomultiplier tube and converted into an without any replacement. A catalytic ozone electrical signal. The number of electrons scrubber is installed for maximize pump life analyzer utilizes chemiluminescence technology is increased by the photomultiplier system and exhaustion safety purpose. indicated by US EPA as federal reference method and the current or voltage is collected by for monitoring on multiple...

Open the catalog to page 9
FPI AQMS-1000 Ambient air quality monitoring system - 10

Ammonia Converter FPI AQMS-650 also comes with its own developed Software. The Remote PC Software allows for a remote connection with virtual Multi-channel Connector O3 Remover interface and data downloading capability to analyzers operating Software. Particulate Filter Nafion Tube Principle FPI AQMS-650 measures NH3 in the ambient Technical Data air, which delivers a stable and precise value. It adopts chemiluminescence technology with an external converter which can combine its use with AQMS-600 measuring NOx as well; Measurement Units during the measurement, NH3 will be converted Lower...

Open the catalog to page 10
FPI AQMS-1000 Ambient air quality monitoring system - 11

BPM-200 Continuous Particulate Monitor Technical Data The BPM-200 measures ambient particulate by using well applied beta ray attenuation technology. PM2.5 measurement can also be achieved by introducing corresponding cyclone. Lower Detectable Limit Sample Flow Rate Particulate matter sample is pulled by a vacuum pump and concentrated on filter tape spot, the concentrated sample is advanced to measuring position where between beta ray source and Flow Accuracy detector. An attenuation signal of beta ray is detected which represents the mass of sample Flow Stability particulate. Particulate...

Open the catalog to page 11