FPI AQMS-1000 Ambient air quality monitoring system
1 /8Pages

FPI AQMS-1000 Ambient air quality monitoring system

FPI AQMS-1000 Ambient air quality monitoring system
1 /8Pages

Catalog excerpts

FPI AQMS-1000 Ambient air quality monitoring system-1

Air Quality Monitoring SystemAQMS-1000 Focused Photonics (HangZhou) Inc. No. 459, Qianmo Road, Bingjiang District Hangzhou China 310052 Tel: +86 571 8501 2188 Fax: +86 571 8501 2188 http: //www.fpi-inc.com/en/ HW 20191110V1P1 AQMS-100 Zero Air Generator AQMS-200 Multi-Point Calibrator AQMS-300 Ozone Analyzer AQMS-400 Carbon Monoxide Analyzer AQMS-500 Sulfur Dioxide Analyzer AQMS-600 Nitrogen Oxides Analyzer BPM-200 Continuous Particulate Monitor

 Open the catalog to page 1
FPI AQMS-1000 Ambient air quality monitoring system-2

AQMS-100Zero Air Generator FPI AQMS-100 provides ultra pure pollutant-free zero air for calibrating zero point of ambient air quality monitor. It consists of air compressing and cooling system, water removal system, gaseous pollutant scrubber system,particle removal and zero gas output system. Principle The AQMS-100 generates clean and dry zero air by removing components which will cause interference on zero point calibration. Water Removal System The primary draining system apply condenser to remove the saturated liquid water in ambient air. The secondary draining systems are used to remove...

 Open the catalog to page 2
FPI AQMS-1000 Ambient air quality monitoring system-3

AQMS-200Multi-Point Calibrator FPI AQMS-200 dynamic dilution calibrator utilizes two mass flow controllers to perform standard zero and span calibration with up to 4 gas sources. Features • Stable trace level ozone output down to 0.1 ppm; • Optional ozone generator, gas phase titration and photometer for independent ozone calibration; • User selectable output include RS232 and ethernet; • High performance mass flow controller provides stable and linearized output; Technical Data Dilution System Dilution Gas Flow Range 0~10SLM, available 0~50sccm,0~200sccm Standard Gas Flow Range 0~100sccm ; available...

 Open the catalog to page 3
FPI AQMS-1000 Ambient air quality monitoring system-4

AQMS-300 Ozone Analyzer FPI AQMS-300 Ozone analyzer measures ambient 03 concentration in ppb level by utilizing UV photometric absorption technology. Principle The instrument measures the concentration of ambient ozone on the basic principle of ozone adsorbing UV lie in chamber with 42 cm optical length for light adsorption since there is a significant characteristic absorption for ozone on wavelength of 254nm. Periodical diversion on sample flow passing through the ozone scrubber will generate reference measurement, which is compared with sample measurement to provide stable and representative...

 Open the catalog to page 4
FPI AQMS-1000 Ambient air quality monitoring system-5

SYNCHRONOUS MOTOR Carbon Monoxide Analyzer GFC GFC (Gas filter correlation) technology is utilized to remove interference caused by moisture and other backgrounds. Infrared energy emitted by light source is passed through gas chamber containing the air sample, and the quantitative absorption of energy by CO in the sample cell is measured by corresponding detector. FPI AQMS-400 carbon monoxide (CO) analyzer measures ambient CO concentration by employing nondispersive infrared with gas filter correlation method technology. Data storage and analysis Stored data are easily retrievable through the...

 Open the catalog to page 5
FPI AQMS-1000 Ambient air quality monitoring system-6

AQMS-500 Sulfur Dioxide Analyzer FPI AQMS-500 sulfur dioxide (S02) analyzer applies UV fluorescence technology with photo multiplier tube (PMT) to measure S02. Features • Compliance with US EPA reference method; • Various outputs include ethernet and RS232; • User friendly interface with large screen; • Continuous system diagnosis with alarm; • Multi-tasking software allows viewing test variables while operating; • Temperature and pressure compensation; • Internal data logging with 1 min to 365 day multiple averages; • Critical orifices provide flow stability; Principle AQMS-500 measures the...

 Open the catalog to page 6
FPI AQMS-1000 Ambient air quality monitoring system-7

Principle Nitrogen oxides in ambient are measured indirectly by photometrically measures the light intensity, resulting from the chemiluminescent reaction of nitric oxide (NO) with ozone (O 3). Nitrogen Oxides Analyzer FPI AQMS-600 nitrogen oxides (NO-NO 2–NOx) analyzer utilizes chemiluminescence technology indicated by US EPA as federal reference method for monitoring on multiple forms of nitrogen oxides. PMT System The characteristic fluorescence of unstable excited-state NO 2 is received by the photomultiplier tube and converted into an electrical signal.The number of electrons is increased...

 Open the catalog to page 7
FPI AQMS-1000 Ambient air quality monitoring system-8

Continuous Particulate Monitor The BPM-200 measures ambient particulate by using well applied beta ray attenuation technology. PM 2.5 measurement can also be achieved by introducing corresponding cyclone. Particulate matter sample is pulled by a vacuum pump and concentrated on filter tape spot, the concentrated sample is advanced to measuring position where between beta ray source and detector. An attenuation signal of beta ray is detected which represents the mass of sample particulate. Particulate concentration can be determined by dividing mass to volume which has been strictly controlled...

 Open the catalog to page 8