Ambient Air Quality Monitoring System
28Pages

{{requestButtons}}

Catalog excerpts

Ambient Air Quality Monitoring System - 1

Ambient Air Quality Monitoring Network System Ambient Particulate Source Analysis System Ambient Photochemical Pollution Monitoring System Ambient Monitoring Management Platform

Open the catalog to page 1
Ambient Air Quality Monitoring System - 3

I AMBIENT AIR QUALITY MONITORING NETWORK SYSTEM Standard AQMS Compact AQMS Micro AQMS Dust Monitoring System Mobile Station Micro Pulse Lidar □ AMBIENT PARTICULATE SOURCE ANALYSIS SYSTEM XRF Metal Analyzer Carbon Analyzer Soluble Ion Analyzer TOF-MS PM Analyzer Application AMBIENT PHOTOCHEMICAL POLLUTION MONITORING SYSTEM Photochemical Precursor Monitoring Photolysis Rate Monitoring Characteristic Product Monitoring AMBIENT MONITORING MANAGEMENT PLATFORM Platform Function

Open the catalog to page 3
Ambient Air Quality Monitoring System - 4

AQI (Air Quality Index) network monitoring provides general pollutant data and gives administrative support; whereas source analysis demonstrates the formulation of pollutants. The combination of two approaches gives specific evidence of ambient forecast and right solution for treatment. FPI’s Ambient Air Monitoring Network solution intended to provide monitoring, evaluating and analyzing services to local environmental authority (e.g. environmental protection agencies) to help users acquaint with regional ambient status, find pollution characteristics for supporting the decision of air...

Open the catalog to page 4
Ambient Air Quality Monitoring System - 5

I STANDARD AQMS FPI’s standard stationary AQMS consists of full sets of analyzers apply general online reference and equivalent method for monitoring regular air quality parameters, intention of these stations are to generate reference and representative point-wise AQI in such region. These stations and data are considered as state level standard data to be published. ▲ Ambient air quality automatic monitoring system

Open the catalog to page 5
Ambient Air Quality Monitoring System - 7

AQMS-100 The AQMS-100 generates clean and dry zero air by removing components which will cause interference on monitoring results. Features and Benefits • Ultra high purity zero air output. • Regenerative dryer utilizing molecular sieve reduces maintenance cost. The AQMS-200 Dynamic calibrator utilizes mass flow controller to perform standard zero and span calibration with up to 4 gas sources. Features and Benefits • Stable trace level ozone output down to 0.05 ppm. • Optional ozone generator, gas phase titration and photometer for independent ozone calibration. • User selectable output...

Open the catalog to page 7
Ambient Air Quality Monitoring System - 8

1 COMPACT SYSTEM The Compact system is the alternative solution against standard AQMS, it comes with integrated shelter consisting IPC, sampler, AC and all necessary accessories. Comparing to the regular station, the compact one covers all advantages but less land area with miniaturization instruments, which is more cost-effective. Being extendable for VOCs or other analyzers, this type of system will be typically installed at tunnel or traffic joints, which needs online monitoring, but has land limitation. This system is applied key roads and villages which is critical for municipal or...

Open the catalog to page 8
Ambient Air Quality Monitoring System - 9

Micro AQMS gives a macro indication in terms of trend analysis against stationary AQI analysis. Target of micro AQMS is to find out the pattern of pollution spatial distribution during certain period. These data supports AQI result at standard station and most importantly, it give macro idea on municipal management Features and Benefits • Customization on parameters according to customer requirement. • Simultaneous monitoring 10 parameters including PMIOand PM2.5. • 4G module enables remote control. • PreCalTM (Pre-calibration), FieldCalTM (Synchronize calibration) and OnTheFlyTM (Portable...

Open the catalog to page 9
Ambient Air Quality Monitoring System - 10

Dust from construction, demolition and traffic can cause significantly impact on local air quality, posing health problem. Hence, the dust mitigation monitoring is required at most construction sites. CDMS-1000 is designed with light scattering technology for continuous real-time measurement of particulate concentration along with noise and meteorological parameters. This combination consists of particle analyzer, camera, sound level meter and GPRS module. Features and Benefits • Measurement of TSP, PM 10 & PM2.5, noise, meteorological parameters online. • Particulate module and sound level...

Open the catalog to page 10
Ambient Air Quality Monitoring System - 12

MOBILE STATION Mobile air quality monitoring system consists of analysis devices, an automatic sampler, an image acquisition device, and a mobile communication device. Instruments combination can be selected and moved as per requirement, such flexibility enables the mobile station to perform as fixed station as well. Features and Benefits • Atmospheric mobile station reaches the scene quickly and uses portable equipment to quickly identify and predict pollution. • As a supplement to regular station and laboratory testing, mobile station can effectively improve regional environmental...

Open the catalog to page 12
Ambient Air Quality Monitoring System - 13

Micro Pulse Lidar (MPL) applies linear polarization laser of 532 nm for Scanning distribution of atmospheric particulate matter. By sensing the vertical and horizontal polarization signal, Lidar monitors the change process of PM, the spatio - temporal evolution characteristics of particulate matter, alert the air quality changes at the city (or region) boundary and locate the Pollution source quickly. Features and Benefits • Using galvanometer scanner to prevent vibration of Lidar main light machinery parts and electrical detector. • Galvanometer scanner has the function of automatic dust...

Open the catalog to page 13
Ambient Air Quality Monitoring System - 14

Particulate in the atmosphere can penetrate deep into the lungs and enter the body systematically, affecting the cardiovascular and other major organ systems and increasing risks of pre-mature mortality from heart attack, respiratory infections, and lung cancer. Traditional off-line method collects sampled aerosols on filters and analyzes back in lab, it usually takes a long sampling time which sample validity could be doubted. Thus, the off-line method is difficult to represent the actual state of the atmosphere. To solve these challenges, FPI applies PMF model (Probabilistic Matrix...

Open the catalog to page 14
Ambient Air Quality Monitoring System - 15

The system integrates X-ray fluorescence for metal analysis up-to 30 elements and beta-ray attenuation model for particulate mass monitoring. But module will be using same sample moving sequentially across the detector, and would be significantly effective in industry emission tracing. Features and Benefits • Measuring 30 toxic metals simultaneously. • Magnitude of detection limit 0.01 -0.1 ng/m3 level. • Nondestructive test that the membrane sample can be preserved. • Associate measurements with time of day or meteorological conditions, makes particular source tracing possible. •...

Open the catalog to page 15

All Focused Photonics Inc. catalogs and technical brochures

  1. FPI Profile

    12 Pages

  2. LGA-3500

    2 Pages

Archived catalogs