FOCUS-1 - 1

PROCESS MEDIA Single phase liquid with <5% solid content, <2% gas content and max. Viscosity up to 100 cSt Direct Flow control applications replacing either just a valve or combination of valve with other equipment (e.g. flowmeter) MEASUREMENT SENSOR ELEMENTS CONTROL ELEMENT ELEMENT NAME Valve position % or Flow control MEASURED & CALCULATED PARAMETERS Double acoustic reflection path % Opening at real time dynamic flowrate conditions Flow velocity Inlet pressure Cavitation, Flashing and Estimated Sound Pressure level Kv Volumetric flowrate Outlet pressure Pressure drop Overall Control Accuracy Measurement accuracy Uncertainty, typically better than 0,5% of setpoint value and stability better than + 0,2%. Pressure measurement range Burst pressure Temperature measurement range Body / Bonnet Process Connection 1.4409 (stellited version optional) 1.4404 (stellited version optional) Sensor Diaphragm Packing Gasket PTFE/PTFE with Carbon PTFE/graphite with metal core Seat leakage ANSI Class IV & ANSI Class V Electronics Version Version 4.0 Size, Seat bore, and Kv TECHNICAL PARAMETERS With an inbuilt PID controller, control accuracy is typically ± 1% DN 50 with SB 24mm & Kv 10 DN 50 with SB 38mm & Kv 25 DN 50 with SB 48mm & Kv 40 Electrical connection Spring clamp connections according to VDE 0100 Manufacturer Standard Pneumatic conn. Power supply Power Consumption Cable entry MATERIAL OF Plug CONSTRUCTION DEVICE PARAMETERS Pressure class DEVICE PARAMETERS Flanged connections according B1 EN 1092-1 Trim type Standard V - Port plug with Metal seal Flow characteristics Linear / Eq % as standard Linear when flow used as setpoint FOCUS-ON VoF | A SAMSON & KROHNE COMPANY Kerkeplaat 12, 3313 LC Dordrecht, The Netherlands K.v.K. 74863223 Changing the flow forever

Open the catalog to page 1
FOCUS-1 - 2

Design temperature Min. 4 DN ( straight inlet ) 0 DN ( straight outlet ) Face to Face Dimension Design pressure Ambient conditions DEVICE MANAGEMENT & VALUE-ADDED FEATURES APPROVALS & CERTIFICATES All inputs and outputs are galvanically separated from main power supply and each other. Through a browser user interface all operating settings can be reviewed and adjusted Input & Output Signal Input Signal for Set Point : 4-20 mA Output Signal to DCS/PLC : 4-20 mA (active & passive), HART7® Protocol Digital Twin Technology Sensor redundancy owing to the diagnostic algorithms on-board that use...

Open the catalog to page 2

All FOCUS ON catalogs and technical brochures