1. Catalogs
  2. Fluke Process Instruments
  3. Raytek XR Datasheet English

Raytek XR Datasheet English
1 /2Pages

Raytek XR Datasheet English

Raytek XR Datasheet English
1 /2Pages

Catalog excerpts

Raytek XR Datasheet English-1

Highlights • Multiple temperature and spectral ranges • Local user-interface for sensor programming • User-selectable 0/4-20 mA, 0-5 V, J or K thermocouple output • User-scalable 0/4-20 mA or 0-5 V output • Simultaneous analog and digital RS485 outputs • Choice of terminal wiring or DIN connector wiring • Laser sighting for high resolution optics (LTH models) • Optional stainless steel housing • Field Calibration software Electrical Specifications Measurement Specifications J or K thermocouple (with terminal connector) Digital RS485 (bidirectional) Alarm opto-coupled contact closure Inputs Emissivity setting, background radiation compensation, trigger, laser control Power Supply 24 VDC ±20%, 100 mA Temperature/Spectral Ranges LT/LTHSF (Low Temp.) -40 to 600°C 8 to 14 pm General Specifications Environmental Rating IP65 (IEC529), with DIN connector only Ambient Temperature without cooling 0 to 70°C with water cooling 175°C Shock IEC 68-2-27, 50 G, 11 ms, 3 axis with cooling jacket 192 mm L x 63 mm diameter with cooling jacket 675 g Signal Processing °C/°F, Min, Max, Average, advanced hold, ambient background temperature compensation Sensor and Fixed Bracket Each sensor comes with a fixed bracket, a mounting nut, a software CD and an operator’s manual. 90% energy, standard focus optics LT: for target temperature > 25°C @ ambient temperature of 23°C; P7: for target te

 Open the catalog to page 1
Raytek XR Datasheet English-2

Optical Specifications Options must be specified at time of order. • Manufacturer's calibration certificate based on NIST/DKD probes (XXXXRCERT) • RS232/485 converter serving for stand-alone or multiple sensors (RAYMINCONV2) • Protective Windows according to spectral range (XXXTXACTW...) • Cable extensions in different lengths • Water/Air Cooled Housing for field retrofit as stainless steel (XXXXRACWCS) or aluminium (XXXXRACWCA) • ThermoJacket: extra rugged cast metal housing for thermal/mechanical environmental protection (RAYTXXTJ5) Fixed Bracket (XXXTXXACFB) Water/Air Cooled Housing (sensor...

 Open the catalog to page 2

All Fluke Process Instruments catalogs and technical brochures

  1. Fiber- Optic

    3  Pages

  2. Datapaq TP6

    4  Pages

  3. Raytek®CM

    4  Pages

  4. Datapaq® DP5

    4  Pages

  5. DATAPAQ XDL12

    2  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.