Raytek®CM

Raytek®CM

Raytek®CM

Product catalog summary
Overview: The Raytek® CM sensor is a compact, noncontact infrared temperature measurement device designed for industrial applications and OEMs. It offers a temperature range of -20°C to 500°C (-4°F to 932°F) and is housed in a rugged IP 65 (NEMA-4) stainless steel casing.
Specifications:
  • Temperature Range: -20°C to 500°C (-4°F to 932°F)
  • Accuracy: ±1.5% of reading or ±2°C, whichever is greater
  • Spectral Response: 8 to 14 microns
  • Repeatability: ±0.5% of reading or ±2°C, whichever is greater
  • Response Time: 150 mSec (95%)
  • Emissivity: Adjustable from 0.10 to 1.10
  • Transmissivity: Adjustable from 0.10 to 1.00
Features:
  • RS232 digital communications for sensor setup and monitoring
  • Adjustable signal processing with peak hold, valley hold, and variable averaging
  • Self-diagnostics with sensor status indicators
  • Alarm output and sensor health LED
  • DataTemp® Multidrop software compatibility
Environmental and Physical Specifications:
  • Ambient Temperature Range: -10°C to 70°C (14°F to 160°F)
  • Storage Temperature: -20°C to 85°C (-4°F to 185°F)
  • Relative Humidity: 10 to 95%, non-condensing
  • Shock and Vibration: Compliant with IEC 68-2-27 (MIL STD 810D)
  • Weight: Less than 200 g (7 oz) with 1m cable
Accessories: Options include adjustable or fixed mounting brackets, right angle mirrors, air purge jackets, and protective lens coverings.
Applications: The Raytek CM sensor is suitable for both OEM and end-user applications, providing a reliable and easy-to-install solution for noncontact temperature measurement.
See more

Catalog excerpts

Raytek®CM-1

Raytek® Compact Series CM Noncontact Temperature Measurement for Industrial Applications & OEMs

 Open the catalog to page 1
Raytek®CM-2

Measurement Specifications CM Highlights Scaleable 0-5 V, type J or K output ■ ide -20°C to 500°C (-4°F to 932°F) W temperature range ■ Rugged IP 65 (NEMA-4) stainless steel housing ■ Rugged 13:1 optics at 90% energy ■ 150 mSec (95%) response time ■ Alarm output ■ ensor status/self diagnostic S indicator LED ■ S232 digital communications for R sensor set-up and monitoring ■ Adjustable signal processing ® ■ DataTemp Multidrop software compatible ■ ccessories for air purging and A lens protection ■ The Raytek® CM sensor provides the advantages of infrared temperature measurement in a powerful,...

 Open the catalog to page 2
Raytek®CM-3

Electrical Specifications Analog Outputs Model specific Type J, Type K or scaleable 0-5V voltage output Cable Length (3.3 ft) standard 1m 3m (9.8 ft) cables optional Thermocouple Output Impedance Voltage Output Minimum Load Impedance 50K ohms Power Supply 24 VDC ±20% @ 20mA Two-way RS232 digital output Digital Output Alarm Output 5 Digital output and alarm output share a common wire. User selects either alarm output or RS232 communication via Datatemp Multidrop software. Sensor Specifications Environmental Rating A bient Temperature Range -10ºC to 70°C (14ºF to 160°F) m Cable Temperature Range...

 Open the catalog to page 3
Raytek®CM-4

Model RAYCMLT Cable Length Housing Thread Output Type J Thermocouple Output Type K Thermocouple Output Voltage Output (Linear, scaleable from 0-5V) Description Raytek infrared temperature sensor Cable Length 1M (3.3ft) Cable 3M (9.8ft) Cable Housing thread Standard 0.75-16 UNF 18 MX1 Metric Typical Model Number Adjustable Mounting Bracket Protective Window Right angle mirror Fluke Process Instruments Americas Santa Cruz, CA USA Tel: +1 800 227 8074 (USA and Canada, only) +1 831 458 3900 [email protected] EMEA Berlin, Germany Tel: +49 30 4 78 00 80 [email protected]...