Overview
The document introduces the Reflow Tracker system by Datapaq, highlighting its advanced thermal profiling capabilities through the use of Insight™ Software and Q18 data loggers. The system is designed for ease-of-use, accuracy, and reliability in monitoring thermal processes.

Insight™ Software
Insight™ Software is a user-friendly tool that interprets data from the Q18 logger, providing instant analysis. It simplifies the setup of multiple processes with step-by-step wizards and offers a comprehensive Reflow Results summary screen. The software includes SPC analysis to ensure process control and quality.

Q18 Data Loggers
The Q18 family of data loggers is noted for its versatility and durability, offering features such as ultra-fast USB connections, small footprints, and rapid charging. These loggers support up to 12 channels and are designed for demanding thermal profiling tasks.

System Enhancements
  • Easy Oven Setup (EOS): Automates recipe definition to optimize reflow oven settings, reducing trial-and-error.
  • Surveyor™: Monitors thermal performance without test boards, using fixed sensors and specialized software.
  • Wave Solder Pallet: Facilitates accurate measurement of wave solder processes, analyzing critical parameters automatically.


Thermal Barriers
Datapaq offers lightweight, durable stainless steel barriers capable of withstanding high temperatures. These barriers are customizable to meet specific process needs.

Technical Specifications
The document provides detailed specifications for Q18 data loggers, including memory capacity, sampling intervals, accuracy, and temperature ranges. It also lists compatible thermal barriers with their dimensions and temperature endurance.

Support and Warranty
Datapaq systems come with a one-year warranty, with options for yearly service and re-calibration contracts. Global support is available through Fluke Process Instruments.

Contact Information
Contact details for regional offices in EMEA, Americas, China, and Asia are provided for further inquiries and support.
See more

Catalog excerpts

Datapaq Reflow Tracker® System-1

Reflow Tracker for complete thermal profiling

 Open the catalog to page 1
Datapaq Reflow Tracker® System-2

For over twenty years, the Datapaq® name has stood for exceptional value in thermal process monitoring. So it’s no surprise that the most recent Datapaq innovations meet and exceed the highest standards for ease-of-use, ruggedness and accuracy. The Q18 family of loggers features the industry’s broadest range of sizes and configurations for quick and easy monitoring of even the most demanding processes. Combine your Q18 logger and barrier with Easy Oven Setup (EOS) and Surveyor™ for the industry’s fastest, most cost-effective solution for thermal process setup and monitoring. Our Insight™ software...

 Open the catalog to page 2
Datapaq Reflow Tracker® System-3

QI8 Data Loggers The most advanced and versatile family of loggers from Datapaq These loggers go where no logger has gone before. Whether you need ultra low height, an incredibly narrow footprint, or up to 12 channels with rapid sampling, a Q18 logger is your best choice. Built with legendary Datapaq durability and accuracy, these loggers give years of reliable profiling. • Ultra-fast USB connection • Small footprint: less than 63.5 mm (2.5 in) wide, 12.7 mm (0.5 in) high • Rapid charging The environmentally friendly NiMH battery charges from flat to usable in five minutes. A full charge takes...

 Open the catalog to page 3
Datapaq Reflow Tracker® System-4

Technical Specifications QI8 Data Logger Memory Sampling Interval Accuracy Resolution Maximum Internal Operating Temperature Temperature Range Data collection start Battery Thermocouple 55,000 readings per channel 0.05 seconds to 10 minutes ±0.5°C (±0.9°F)_ Start/Stop buttons, time or temperature trigger Nickel Metal Hydride (NiMH) rechargeable Type K, Special Limits of Error ANSI MC 96.1 Length Weight Standard System Thermal Barriers Height Width Length Weight Time @ Temperature (mins) DQI86I Suitable Thermal Barriers TB2066 20 mm (.79 in) 88 mm (3.4 in) 334 mm (I3.I in) 0.65...