1. Catalogs
  2. Fluke Calibration
  3. 5128A RHapid-Cal Humidity Generator
video corpo

5128A RHapid-Cal Humidity Generator

5128A RHapid-Cal Humidity Generator

5128A RHapid-Cal Humidity Generator

Product catalog summary
Overview: The Fluke Calibration 5128A RHapid-Cal Humidity Generator is a portable device designed for calibrating humidity probes both in laboratories and on-site. It is particularly useful in industries where humidity measurement is critical, such as pharmaceuticals and food production. The device offers a 33% faster calibration process compared to traditional methods and supports multi-point calibrations for enhanced accuracy.
Key Features:
  • System Accuracy: Offers a best-in-class accuracy of ±1.0% RH, covering all error sources, and allows for improved calibration uncertainty with external references.
  • Rapid Stabilization: Fast response times for humidity and temperature changes, enabling a six-point calibration in two hours.
  • On-Site Calibration: Supports multi-point calibration, providing more reliable results than single-point checks.
  • Versatile Design: Accommodates a wide range of sensors with a five-port door and optional transparent door with a shelf.
  • Portability: Compact and lightweight, making it easy to transport and use in various locations.
  • ISO 17025 Calibration: Comes with an accredited system calibration, ensuring optimal performance.
  • Maintenance: Easy to maintain with a front-loading desiccant cartridge and no special shutdown routines required.
Specifications:
  • Power: Operates on 100 V to 240 V AC, with a power consumption of 300 VA.
  • Environmental Conditions: Operates in ambient temperatures of 18 °C to 28 °C and up to 80% RH.
  • Dimensions and Weight: Measures 237 mm x 432 mm x 521 mm and weighs 15 kg.
  • Temperature and Humidity Resolution: Display and USB data resolution of 0.1 °C and 0.1% RH respectively.
Technical Specifications:
  • Chamber Specifications: Provides detailed specifications for temperature and humidity ranges, uniformity, and stability.
  • Operational Limits: Includes a graph for maximum % RH at various chamber temperatures.
Ordering Information: Lists available models and accessories, including desiccant cartridges, doors, grommets, and transport cases.
Additional Information: Fluke Calibration offers a wide range of calibration solutions and services, accessible via their website.
See more

Catalog excerpts

5128A RHapid-Cal Humidity Generator-1

RHapid-Cal Humidity Generator Fast, portable humidity probe and logger calibration with accredited 1 % RH system accuracy

 Open the catalog to page 1
5128A RHapid-Cal Humidity Generator-2

Humidity calibration in the laboratory or on-site in the field The Fluke Calibration 5128A RHapid-Cal Humidity Generator is a portable humidity generator for calibrating a large workload of probes in the laboratory or on-site in the field. It is used by corporate calibration/research labs and independent calibration labs where humidity measurement is critical to prevent spoilage of products in industries including pharmaceuticals, medical devices, semiconductors, chemicals, and food production. In the lab, the 5128A calibrates humidity probes 33 % faster than a two-pressure generator. In the...

 Open the catalog to page 2
5128A RHapid-Cal Humidity Generator-3

5128A overview Display shows set points and actual temperature and humidity, plus the calculated dew point. Soft keys on the control panel make it easy to cycle through the command menu. Mixing insert causes the air to circulate for better temperature and humidity uniformity inside the insert. Desiccant cap provides easy, front-panel access to desiccant cartridge. Sample In/Out port draws and returns gas to the working chamber. Used to measure the chamber’s dew point with a chilled mirror instrument. Inlet/outlet holes and fan filters. Fill inlet for filling the humidity generator with distilled...

 Open the catalog to page 3
5128A RHapid-Cal Humidity Generator-4

Seven key features of the 5128A RHapid-Cal Humidity Generator 1 Best-in-class system accuracy for dependable humidity probe calibration The 5128A RHapid-Cal offers a best-in-class humidity system accuracy of ± 1.0 % RH (7 % to 80 % RH, 18 °C to 28 °C) which includes all known sources of error such as stability, uniformity, drift, and calibration uncertainty. Calibrate with confidence using an instrument with comprehensive specifications. Most competing generators don’t specify system accuracy. Their specifications can be complicated and confusing, making it difficult to know how to apply them...

 Open the catalog to page 4
5128A RHapid-Cal Humidity Generator-5

5 Compact size and lightweight for easy transport The 5128A RHapid-Cal measures 237 mm high x 432 mm wide x 521 mm deep (9.3 in x 17 in x 20.5 in) and weighs just 15 kg (33.06 lbs). It can be easily carried to any desired bench space in the lab or transported on-site to a field work location. Its front-loading internal desiccant cartridge design adds convenience and ruggedness. In comparison, a two-pressure humidity generator is practically limited to laboratory use because of its large size. It includes a generator, compressor, and supporting equipment. A “small” two-pressure generator requires...

 Open the catalog to page 5
5128A RHapid-Cal Humidity Generator-6

General specifications General specifications AC mains voltage Standard frequency range Power consumption Required test fluid Distilled water Warm-up period Twice the time since last warmed up, to a maximum of 30 minutes Mains fuse rating Operating ambient relative humidity range, 18 °C to 28 °C Storage temperature and relative humidity Transducer power output 12 V dc, 1 A maximum, fuse: F 1A 250 V (fast blow) Computer interface IEC 61010-1, Installation Category II, Pollution degree 2, Indoor use only Electromagnetic compatibility (EMC) International IEC 61326-1: Controlled electromagnetic environment...

 Open the catalog to page 6
5128A RHapid-Cal Humidity Generator-7

Humidity and temperature chamber technical specifications The Product specifications describe the Absolute Instrumental Uncertainty of the Product. The Product specifications include stability, ambient temperature, and humidity (within specified limits), linearity, line regulation, the reference standard measurement uncertainty and long term stability of one year. The product specifications are provided at a 99 %, k=2.58, normally distributed level of confidence, unless otherwise noted. Chamber specifications One year, ambient temperature range 23 °C ± 3 °C1 Chamber temperature range Chamber...

 Open the catalog to page 7
5128A RHapid-Cal Humidity Generator-8

Ordering Information Models 5128A RHapid-Cal Humidity Generator with one Square 5-Port Door, one Desiccant Cartridge, one Fill Syringe with Extension Tube, five Grommets (one each of 1/4 inch, 3/8 inch, 1/2 inch, 3/4 inch, 7/8 inch sizes), one Mains Power Cord 2-meter, Fluke ISO 17025 Accredited System Calibration, 115 V ac/230 V ac Desiccant Cartridge (including desiccant material) Round Door, 5 ports Square Door, clear with shelf Square Door, 5 ports (spare) 5128A Case with wheels Port Grommets, 1/4 inch, 5 each Port Grommets, 3/8 inch, 5 each Port Grommets, 1/2 inch, 5 each Port Grommets,...

 Open the catalog to page 8
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.