This document provides technical specifications and features of a power amplifier designed for proportional directional valves. It is controlled by a modern microcontroller and housed in a compact casing. Adjustments can be made via potentiometers for various parameters including Imin, Imax, RAMP, and PWM frequency.
Features
  • Power amplifier for proportional directional valves.
  • Controlled by a microcontroller.
  • Compact housing with potentiometer adjustments.
  • Adjustable current range via DIL switch: 0.8A and 1.6A.
Technical Data
  • Power Supply: 10-30 VDC (including ripple).
  • Current Consumption: Less than 60 mA plus solenoid current.
  • External Fuse: 3A (fast).
  • Analogue Inputs: Various voltage and current ranges including +/- 10V, 0-10V, and 4-20mA.
  • Reference Voltages: 8V and 10V with a maximum of 10 mA.
  • PWM Outputs: Maximum load of 0.8A or 1.6A, frequency adjustable between 70-125 Hz.
  • Adjustments: Imin (0-60%), Imax (0.7-1.6A), RAMP (0.05-15s), PWM Frequency (70-125 Hz).
  • Housing: Snap-On Module EN 50022, made of Polyamide PA6.6, combustibility class V0-V2 (UL94).
  • Protection Class: IP20.
  • Temperature Range: -20°C to 55°C.
  • Humidity: Less than 90% (non-condensing).
  • Dimensions: 120mm (d) x 100mm (h) x 23mm (w).
  • Connections: RS232, 3.5mm JISC-6560, 4x4pol. Screw terminals, PE via DIN rail.
  • EMC Standards: EN 50081-1, EN 50082-2.
Block Diagram
The block diagram illustrates the connections and components of the digital valve amplifier, including power supply, input, solenoid current range, and microcontroller unit (MCU).
Contact Information
AMCA HYDRAULIC FLUID POWER B.V., The Netherlands. Phone: +31 (0)50 3023577, Fax: +31 (0)50 302 1226, Email: [email protected], Website: http://www.amca-nl.com
See more

Catalog excerpts

PROam20 - Digital valve amplifier-1

Features • Power amplifier for proportional directional valves • Internal controlled by a modern microcontroller • Compact housing • Adjustment via potentiometer • Imin, Imax, RAMP and PWM-frequency adjustment via potentiometer • Current range (per DIL switch): 0,8A and 1,6A Technical data Power supply [VDC] 10…30 (incl. ripple) Current consumption [mA] <60 + solenoid current External fuse [A] 3 (fast) Analoque inputs [V] +/- 10 [V] +/- 8 [V] 0…5…10 [V] 0…4…8 [mA] 4…12.20 [V] +/- 5 [V] +/- 4 [mA] 4…20 Reference voltages [V] 8; 10 mA max. PWM outputs max. load [A] 0,8 or 1,6 (per DIL switchable) Frequency [Hz] 70…125 Sample time (signal conditioning) Depending of the PWM frequency Adjustments Imin [%] 0…60 (0=preadjusted) Imax [A] 0,7…1,6 [A] 0,4…0,8 RAMP [s] 0,05…15 (0,05=preadjusted) PWM Frequency [Hz] 70…125 (125=preadjusted) Housing Snap-On Module EN 50022 Polyamide PA6.6 Combustibility class V0…V2 (UL94) Protection class [IP] 20 Temperature range [°C] -20…55 Humidity [%] <90 (not condensing) Dimensions [mm] 120(d) x 100(h) x 23(w) Connections RS232: 3,5mm JISC-6560 4x4pol. Screw terminals PE: direct via DIN rail EMC EN 50081-1 EN 50082-2 Block diagram AMCA HYDRAULIC FLUID POWER B.V. Tel. +31 (0)50 3023577 P.O.BOX 18 9790 AA Ten Boer NL Fax. +31 (0)50 302 1226 B.Kuiperweg 33 9792 PJ Ten Post NL e-mail: [email protected] The Netherlands homepage: http://www.amca-nl.com Digital Valve Amplifier Series PROam 20 Publ. L-EA-20-E-05/07 Power supply 7 8 1 2 12..30V 0V PROam20 Power stage MIN A MAX A 10 9 Input +/- 10 V, +/- 8 V, 0...10 V 0... 8 V 12 8 V reference voltages DITHER RAMP 5 V 8 V Enable 15 MCU 3 4 MAX B MIN B 11 S1.1 S2.1 S2.2 Solenoid current range P1 P2 P5 P6 P3 P4 Solenoid A Solenoid B S1.2 S1.3 4... 20 mA 13