Specifications:
  • Motor supply: 240VAC, 240/400VAC
  • Nominal flow rate: 2, 4, 6, and 8 l/min (0.5, 1.0, 1.6, and 2.1 USgpm)
  • Filtration rating: 3 to 200
  • Filter element max. work pressure: 2.5 bar (35.7 psi)
  • Filter housing max. work pressure: 5 bar (71.5 psi)
  • Mounting position: Vertical
  • Size working port (inlet and outlet): 3/8 BSP
  • By-pass setting: 2.0 bar (28.6 psi)
  • Max. fluid temperature: +80°C (+176°F)
  • Viscosity range: 10…500cSt
  • Weight: 13 kg
  • Indicator: Pressure gauge 2.5 bar (35.7 psi)
  • Media: AMCA-ACFF-3
Performance and Benefits:
  • AMCA Constant Flow Filters ensure hydraulic fluid circulates at a constant flow rate, maintaining system cleanliness and meeting steady state conditions of the multipass test.
  • The AMCA-ACFF-3 element reduces disposal weight by over 50% due to the removal of metal parts.
  • Remaining oil can be removed easily, further reducing disposal costs.
  • Durable metal re-useable sleeve and silicone bottom prevent dirt backflow during element change.
  • Equipped with glass fibre media with filtration finenesses of 1 or 3 micron.
Technical Data:

Publication: L-ACFF-EP-E-11/02

Company: AMCA Hydraulic Fluid Power BV, The Netherlands

Contact: [email protected], www.amca-nl.com

Diagram Analysis:

The diagram illustrates particle count over time, showing the effectiveness of the filter in maintaining low contamination levels for particles >5, >10, and >15 microns.

See more

Catalog excerpts

ACFF-EP - Constant flow filter with motor-pump-1

AMCA CONSTANT FLOW FILTER Series EP Offline-filter with motor-pump Motor supply 240VAC, 240/400VAC Nominal flow rate 2, 4, 6 and 8 l/min (0.5, 1.0, 1.6 and 2.1 USgpm) Filtration rating 3 200 Filter element max. work pressure 2.5 bar (35.7 psi) Filter housing max. work pressure 5 bar (71.5 psi) Mounting position Vertical Size working port (inlet) 3/8 BSP Size working port (outlet) 3/8 BSP By-pass setting 2.0 bar (28.6 psi) Max. fluid temperature + 80C (+176F) Viscosity range 10…500cSt Weight 13 kg. Indicator Pressure gauge 2.5 bar (35.7 psi) Media AMCA-ACFF-3 AMCA CONSTANT FLOW FILTERS PERFORM BETTER In real conditions some filter elements tend to perform not as well as evaluated through a multipass test. Variable flow rate and vibration show an unacceptable drop in removal efficiency (â-rating) and dirtcapacity. Clouds of contamination, downstream the filter, could result in component failure. AMCA CONSTANT FLOW FILTERS (ACFF) ensure that hydraulic fluid continually circulates through the filter elements at a constant flow rate. Thus meeting the steady state conditions of the multipass test and keeping the system clean at all time. The AMCA-ACFF-3 element offers the following benefits: * Due to the removal of the metal parts of the elements, the disposal weight will be reduced by more than 50%. * The remaining oil in the element can be removed by means of simple pressing sequence. This will reduce the disposal costs even more. * The metal re-useable sleeve is made from durable materials. * The elements are equipped with a silicone bottom in order to prevent dirt being flushed back during element change. * The elements are equipped with the glass fibre media with filtration finenesses of 1 or 3 micron. TECHNICAL DATA Publ. L-ACFF-EP-E-11/02 AMCA Hydraulic Fluid Power BV