BftTCH CONTROL^ Application examples: Truck or tank filling Pharmaceutical industry Food industry The N-Series distinguishes itself by its userfriendly features: Numerical keypad, easy ticket printing, clear programming menu structure, easy to read display and simple mounting enclosure. The numerical keypad allows simple and fast changing of the preset batch quantity. Advantages • Save time and cost with the easy to operate numerical keypad. • Intuitive "Know one, know them all!” configuration menu, saving time, cost and aggravation. • Key information at a glance as it simultaneously shows actual value, preset value, batch process indication, relay status and selectable measuring units for volumetric or mass. • Easy operation to enter a batch value and to control the proces. Features • Certified by NTEP. • Receipt printing function after each batch. • Rugged aluminum DIN-size panel mount enclosure. • 7 large digits (14mm, 0.56”) for total, flow rate and acc. total. • 10 smaller digits (8mm, 0.3”) for preset value and batch count. • Ability to process all types of signals: Reed-switch, open collector, NPN/PNP pulse or active 8 / 12 / 24V pulse signals. • 5 remote inputs: START, HOLD, RESUME, keypad lock, alarm. • Two heavy duty relays, configurable for i.e. batching with 1- or 2-stage or pump control with on/off time delay function. • Three transistor outputs for connection to PLC’s or other controlling equipment. • No-flow monitoring and automatic over
Open the catalog to page 1Introduction The legal-for-trade N414 batch controller combines accurate batching and user-friendly operation. It is certified by NTEP for wholesale and custody transfer applications in the United States of America. The numerical keypad allows simple and fast changing of the preset batch quantity. Fluidwell stands for simplicity and reliability which is now available in N414. Display The unique LCD display provides multiple batch control data at a glance. The main information like actual value, flow rate or batched total are displayed with 7 large digits (14mm, 0.56”). The preset value and units...
Open the catalog to page 2Your success counts No-flow monitor Printer accessories Following the START command, the flowmeter generates a signal. An external printing device is neccessary, below handheld and If this fails to come within the programmed time, an alarm is panel printers are optional available as accessory. triggered. The batch is interrupted and the latest process values are stored in the memory. At the same time, the cause of the alarm is displayed. Alarm conditions are indicated visibly and can be configured as an alarm output. The No-flow function detects the absence of liquid, an obstruction in the pipeline...
Open the catalog to page 3Your success counts Overview application N414 Accurate and legal-for-trade batching or filling of liquids for wholesale and custody transfer applications with easy ticket printing on location. The N414 offers the perfect solution for batch control applications where a user-friendly instrument is required. Whether you focus on its clear display information, the very easy to operate numerical keypad or the easy menu-driven configuration structure, you’ve got to have a Fluidwell! Alternative batch controllers with receipt printer driver: F132 & N413. For analog inputs we offer our F-Series and D-Series...
Open the catalog to page 4IR: Batch reset input P: PNP / Namur / Active signal input P: Reed switch / NPN input PRINTER COMMUNICATION Dimensions enclosures SENSOR INPUTS AND SENSOR SUPPLY POWER REQUIREMENT Maximum panel thickness: 6mm (1/4”) SENSOR SUPPLY VOLTAGE CONTROL / ALARM or PULSE OUTPUT MAINS POWER REQUIREMENT CONTROL / ALARM or PULSE OUTPUTS ADDITIONAL INPUTS ADDITIONAL INPUT General information N414 Your success counts The N414 has an IP67 (NEMA Type4X) aluminum DIN size front panel and an IP20 GRP back cover. The removable screw terminal connectors on the back-side and the 4 mounting clamps make the N414 very...
Open the catalog to page 5Typical wiring diagrams N414 communication type CB: RS232 Printer Printer communication type CB: RS232 Flow input: meter input: Flow meter Coilwave) (Sine wave) Coil (Sine Earth Earth Power Power supply supply type PG: Power Power supply supply type PG: 24V DC24V DC Signal Signal type OR: ControlControl output output 1 type 1OR: Make-and-break Make-and-break relay relay Common Common groundground Common Common groundground Flow input: meter input: Flow meter PNPsignal pulse signal PNP pulse Common Common groundground communication type CH: RS485 ModbusModbus communication type CH: RS485 - 2 wire-...
Open the catalog to page 6Technical specifications N414 Your success counts Display_ Type High intensity transflective numeric and alphanumeric LCD, UV-resistant. Bright LED backlight. Intensity adjustable from 0 - 100% in steps of 20%. Good readings in full sunlight and in darkness. Digits Seven 14mm (0.56”) and ten 8mm (0.3”) digits. Various symbols and measuring units. Refresh rate 8 times/sec. General Die-cast aluminum front panel, GRP back enclosure. Polycarbonate window, silicone gasket; UV stabilized and flame retardant material. Keypad Sixteen industrial micro-switch keys; UV-resistant silicone keypad; replaceable...
Open the catalog to page 7Ordering information N414 Your success counts Operator functions_ Functions • Enter a preset value. • Start, hold and stop the batch process. • Total can be reset to zero. • Batch counter can be reset to zero. • End-of-batch ticket printing. Displayed • Preset value. functions • Running batch total or remaining quantity. • Flow rate, total and accumulated total. • Batch counter. • Graphical indication progress of the actual batch. Additional • Active overrun correction functions • Minimum / maximum preset value. • No-Flow monitoring. Preset / Total_ Units L, m3, USGAL, IGAL, ft3, bbl, kg, Ton,...