F018-DATA

F018-DATA

F018-DATA

Product catalog summary
Overview: The F018 Flow Rate Monitor/Totalizer is designed for use in both safe and hazardous areas, with a focus on durability and ease of use in harsh weather conditions. It offers robust construction, versatile mounting options, and user-friendly programming.
Specifications:
  • Operating temperature: -40°C to +70°C (-40°F to +158°F).
  • Enclosure materials: Aluminum or stainless steel 316L, rated IP67/Type4X.
  • Power options: Loop powered, battery powered, or 8-30V DC.
  • Sensor supply voltages: 3.2, 8.2, 12, or 24V DC.
Features:
  • Fifteen-point linearization for accuracy.
  • Displays instantaneous flow rate, total, and accumulated total.
  • Red flashing LED for flow rate alarms.
  • HART communication for integration with other devices.
  • Configurable digital output for alarms or pulse output.
Applications: Suitable for extreme weather, certified for intrinsically safe applications with ATEX, IECEx, and CSA approvals.
Configuration and Display:
  • Large digits for visibility.
  • Menu-driven configuration with pass-code protection.
  • Auto backup of settings and totals in EEPROM memory.
Outputs:
  • Galvanically isolated 4-20mA output for linearized flow rate.
  • Digital output for alarm or pulse output, with user-defined pulse width.
Enclosures: Available in various materials, all with IP67/Type4X rating, including GRP panel mount and robust aluminum field mount enclosures.
HART Communication: Facilitates easy reading and modification of settings, ensuring compatibility with HART-enabled systems.
Wiring and Power Supply: Detailed wiring diagrams for different power supply configurations, including loop powered, battery powered, and AC/DC options.
Flowmeter Specifications and Configurations:
  • Input Types: Loop powered 4-20mA, Pulse input.
  • Output Types: Passive transistor pulse, Active 24V DC pulse, Analog 4-20mA, HART communication.
  • Power Supply Options: 8-24V AC/DC, 16-30V DC, 8-30V DC, 115-230V AC, Battery powered.
  • Backlight Options: 20-30V DC, internally powered.
  • Sensor Supply Voltage: 1.2/3.2V DC for pulse flowmeter, 8.2V DC with type PD.
Technical Specifications:
  • Display: High intensity reflective LCD, UV-resistant, 90x40mm.
  • Ambient Temperature: Safe areas -40°C to +70°C.
  • Power Requirements: Various types with specific voltage and power consumption.
  • Sensor Excitation: 3.2V DC for pulse signals, 1.2V DC for coil pick-up.
Data Protection: EEPROM backup of settings, data retention for at least 10 years, password protection for configuration settings.
Standards and Directives: Compliance with EMC, Low Voltage, ATEX, IECEx, RoHS, IP & NEMA standards.
Explosion Protection and Certification: Certified for hazardous areas with classifications such as IIC T4 Ga and IIIC T200 100°C Da, approved by CSA c-us for Class I/II/III, Division 1, Groups A to G T4.
Enclosure Specifications: Various types available, including aluminum, GRP, and stainless steel, with specific ingress protection ratings (IP65/IP67) and cable entry configurations.
Display and Operator Functions: Displays linearized flow rate and total, with alarm settings, multiple units of measurement, and decimal places. Total and accumulated totals are displayed with 7 and 11 digits respectively, with the total being resettable.
Ordering Information: Model F018 includes various configurations for enclosures, power supply, and communication options. The standard configuration is F018-P-AH-CX-HC-OT-PX-XX-ZX.
Additional Notes: Specifications are subject to change without notice, and the document is copyrighted by Fluidwell bv.
See more

Catalog excerpts

F018-DATA-1

Flow rate Monitor / Totalizerwith linearization, pulse/alarm and analog outputs and HART communication mm Application examples: Extreme cold weather regions The F-Series is your first and safest choice for field mount indicators in safe and hazardous area applications. Especially in harsh weather conditions like rain, snow, salty atmospheres and temperatures between -40°C up to +70°C (-40°F up to 158°F). Advantages • Robust aluminum or stainless steel 316L field enclosure (IP67 / Type4X). It is so rugged, a truck can even stand on it! • Intrinsically Safe available - ATEX, IECEx and CSA approval for gas and dust applications. • Programming can be done by your own crew, with the sensible menu-driven structure, saving cost and irritation. Know one, know them all! • Very diverse mounting possibilities: walls, pipes, panels or directly onto outdoor sensors! Features • Fifteen point linearization of the flowcurve - with interpolation. • Displays instantaneous flow rate, total and accumulated total. • 2 alarm values can be entered: low and high flow rate alarm. • Large 17mm (0.67”) digits for flow rate or total. • Red flashing LED backlight in case of a flow rate alarm. • Ability to process all types of signals: Sine wave (coil), NAMUR, NPN/PNP pulse, Reed-switch, Active pulse signals. • HART communication. • 1 configurable digital output for alarm, scaled pulse output of the linearized accumulated total or input retransmission. • Galvanically isolated, loop powered 4 - 20mA output according to the linearized flow rate. • Output loop powered, battery powered or 8 - 30V DC. • Auto backup of settings and runn

 Open the catalog to page 1
F018-DATA-2

The F018 is a local indicator with linearization, that displays the actual flow rate, resettable total and non-resettable accumulated total. The F-Series is known worldwide as a range of user-friendly indicators. The F018 is even more impressive. The HART communication with specific DD allows you to communicate in an easy way with other smart field devices and control / monitoring systems. The display has large 17mm (0.67”) and 8mm (0.31”) digits which can be set to show flow rate and totals. On-screen engineering units are easily configured from a comprehensive menu. The accumulated total can...

 Open the catalog to page 2
F018-DATA-3

Your success counts Overview application F018 The F-Series is your first and safest choice for field mount indicators in safe and hazardous area applications. Especially in harsh weather conditions like rain, snow, salty atmosphers and temperatures between -40°C up to +70°C (-40°F up to 158°F). Flow rate monitoring with a precise calculation over the full measurement range, where re-transmission of the totalizer and monitoring of the flow rate function and HART communication is required. Alternative basic models: F016, F112, F118 or the explosion proof E018 with HART communication. Signal input...

 Open the catalog to page 3
F018-DATA-4

Your success counts Enclosures Various types of enclosures can be selected, all ATEX, IECEx and CSA approved. The F018 is supplied in an GRP panel mount enclosure as standard, which can be converted to an IP67 / Type4X GRP field mount enclosure by the addition of a back case. Most popular is our robust aluminum field mount enclosure which is also available with an extended backcover with undrilled preparation for direct meter mounting at the back side. It is so rugged, even a truck can stand on it! For the most challenging environments we have a durable high grade Stainless steel 316L enclosure....

 Open the catalog to page 4
F018-DATA-5

Common ground Backlight option: type ZB 20 - 30V DC Typical wiring diagrams F018 Your success counts Alarm output type OT: passive transistor Common ground Configuration example F018-P-AH-CX-PB-(PX)-XX-(ZB) Hazardous area applications The F018 has been certified according to ATEX and IECEx by to +158°F). For equipment category D &(EPL Da),(AH): -40°C to HART1(CR) Analog output 11 Power supply • The ATEX markings for gas andoption: dust are: Backlight typeapplications ZB Backlight supply Common ground Circuit depends on type of signal Common ground HART Communication type CR: (not used in this...

 Open the catalog to page 5
F018-DATA-6

Configuration example Ex ia IIC / IIIC - F018-P-AH-CR-OT-PX-XI - Output loop powered Your success counts Configuration example Ex ia IIC / IIIC - F018-P-AH-CR-OT-PX-XI - Output loop powered HAZARDOUS AREA Supply backlight Power supply or Uo = max. 30V switch interface Io = max. 200mA For example MTL 5525 Po = max. 1,2W MTL 5511 Intrinsically Safe apparatus Power supply Alarm output type OT: passive transistor Basic power supply type PX: 8 - 30V DC (not used in this example). Circuit depends on type of signal Common ground Common ground Backlight option: type ZB (not used in this example). Common...

 Open the catalog to page 6
F018-DATA-7

Technical specifications F018 Your success counts Display_ Type High intensity reflective numeric and Digits Seven 17mm (0.67”) and eleven 8mm (0.31”) digits. Various symbols and measuring units. Refresh rate User definable: fast, 1sec , 3sec, 15sec, 30sec, off. Option ZB Transflective LCD with white LED-backlight; Red (flashing) backlight during alarm conditions. Intensitiy and alarm repsonse selected trough the keyboard. Good readings in full sunlight and darkness. Also available Intrinsically Safe. Ambient temperature_ max. dust layer thickness: 200mm. EPL Db / 2D -40°C to +70°C (-40°F to...

 Open the catalog to page 7
F018-DATA-8

Technical specifications F018 Your success counts Aluminum wall / field mount enclosures_ General Die-cast aluminum wall/field mount enclosure IP67 / Type4X with 2-component UV-resistant coating. Extended back cover available with undrilled preparation for direct meter mounting. Dimensions 130 x 120 x 75mm (5.12” x 4.72” x 2.95”) - W x H x D. 130 x 120 x 90mm (5.12” x 4.72” x 3.54”) - W x H x D. Weight 1100 gr. / extended enclosure: 1310 gr. Type HA Cable entry: 2 x PG9 and 1 x M20. Type HL Cable entry: 2 x V2” NPT. Type HM/HBM Cable entry: 2 x M16 and 1 x M20. Type HN Cable entry: 1 x M20. Type...

 Open the catalog to page 8
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.
About DirectIndustry
DirectIndustry is a marketplace that offers B2B players a complete experience, from product sourcing to purchase. DirectIndustry is an entity of VirtualExpo Group.