1. Catalogs
  2. Fluidwell bv
  3. C-Series - Flow & Energy Computers

C-Series - Flow & Energy Computers
1 /6Pages

C-Series - Flow & Energy Computers

C-Series - Flow & Energy Computers
1 /6Pages

Catalog excerpts

C-Series - Flow & Energy Computers-1

Application examples: Boiler Heat exchanger Field mount example The C5-Series is a powerful range of single and dual stream Flow and Energy Computers for gas, steam or liquid applications. The comprehensive and rugged enclosure combines easy installation and operation, resulting in cost reduction. It works with any pulse, differential pressure or analog signal generating flow meter. • Robust IP66/67, Type4X aluminum field enclosure, withstands extreme weather and industrial conditions. • Large, versatile display with bright backlight, all info at a glance. • Easy-to-operate with 6 rugged industrial silicone buttons. • User-friendly operation and configuration via the keypad and display or with the free available configuration software. • Saturated and superheated steam. • Gas such as: air, nitrogen, oxygen, hydrogen, carbon dioxide, natural gas and user defined gasses. • Water, oil, fuels and user defined liquids. • Calculates mass flow, volumetric flow and power at actual and reference conditions for one or two streams. • Determines compressibility, density, enthalpy and specific heat according to recognized standards such as AGA8, SGERG, IAPWS, API and more. • Calculations for related and unrelated dual streams. • Calculates power in each stream. • Calculates totalized values for volume, mass and energy. • Data logging of process parameters and calculated values. • 11 point linearization of all inputs. • Ability to process various flow inputs: pulse (pending), (stacked) differential pressure or other 4 - 20mA signals. • 4 - 20mA inputs for pressure sensors. • 4 - 20mA, Pt100 or Pt500 inputs for temperature sensors. • Up to 2 analog outputs, 2 digital outputs, 2 relay outputs.

 Open the catalog to page 1
C-Series - Flow & Energy Computers-2

Your success counts Single stream Pulse / analog flowmeters Temperature input 2 / 3 stacked or averaging analog flowmeters Temperature input Pressure input Pressure input dP Pulse or analog flowmeter inputs Dual / triple differential pressure flowmeter inputs Water & Steam Water & Steam Semi redundant flow measurement Redundant flow measurement Pressure input Temperature input Dual temperature inputs Dual pressure input Pressure input Temperature input Differential pressure flowmeter input Dual differential pressure or dual pulse generating flowmeter inputs Turbine flowmeter input Water & Steam...

 Open the catalog to page 2
C-Series - Flow & Energy Computers-3

Your success counts Dual streams Differential / sum flow measurement with same media Pressure input Temperature input Temperature input Pressure input Differential pressure or pulse generating flowmeter input Flowmeter input Differential / sum Water & Steam Differential / sum flow measurement with independent media Temperature input Pressure input Stream #1 Pressure input Temperature input Flowmeter input Stream #2 Flowmeter input Water & Steam 2 Channel heater / cooler with fixed inputs Pressure input Pressure and temperature entered as FIXED VALUES Temperature input Pressure input Temperature...

 Open the catalog to page 3
C-Series - Flow & Energy Computers-4

Channels Flow Additional Outputs Display Dual stream, same media and easy-to-use field mount Single- and Dual-stream Dual stream, independent media Analog inputs Pulse inputs Status input Analog output (active / passive, isolated) Configurable digital outputs: Pulse, alarm or switch Configurable relay output: Alarm or switch Large graphical display with adjustable backlight Mass, volumetric flow rate and power Measured temperature and pressure Compressibility, density, enthalpy or specific heat value Density: Fixed values, formula or API table interpolated value Enthalpy: Fixed values, formula...

 Open the catalog to page 4
C-Series - Flow & Energy Computers-5

Your success counts Pulse inputs 2 Analog and 2 pulse inputs Passive isolated analog output Configurable analog outputs (active / passive isolated) 1 x RS485 2-wire Modbus communication & 1 x RS232 communication Flow equations for gas (incl. natural gas: SGERG & AGA8) Flow equations for liquids (inc. crude, refined products and lubrication oil according API) Flow equations for water and steam (saturated / superheated) Flow equations for gas, water & steam and other liquids (EG, EL & ES combined) Aluminum field mount enclosure; Custom cable entry Analog 4 – 20 mA inputs for pressure signals (active...

 Open the catalog to page 5
C-Series - Flow & Energy Computers-6

Feature overview Status icons Mass flow Volumetric flow Energy consumption Customer ID number Status bar with actual stream indication Operational screen Robust aluminium enclosure Large graphical display with bright backlight Easy-to-operate keypad Main menu List of actual values All info Easy Easy Know one Reliable User-friendly at a glance to install to program know them all! Important: specifications are subject to change without notice. Copyright: Fluidwell bv - 2024 - C5SERIES-3FOLDER-EN-V2427

 Open the catalog to page 6
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.