video corpo

BYPASS ROTAMETER

BYPASS ROTAMETER

BYPASS ROTAMETER

Product catalog summary
Overview: The document discusses the functionality and components of bypass glass and metal tube rotameters, which are used to measure flow rates in pipelines. These devices overcome the limitations of traditional orifice meters by providing a linear flow range, making them versatile for various pipeline sizes and flow rates.
Key Components:
  • Mainline Orifice Plate: Creates a pressure differential that varies with flow rate, enabling the meter's function.
  • Orifice Flanges/Carrier Ring: Holds the orifice plate and channels flow between high and low-pressure sides.
  • Variable Area Flow Meter: Measures bypass flow using a glass or metal tube rotameter.
  • Range Orifice: Ensures pressure drop in bypass piping matches the mainline orifice.
  • Bypass Piping: Connects upstream and downstream sides of the mainline taps to the flow meter, affecting accuracy.
Specifications:
  • Accuracy: ± 2% F.S.D.
  • Repeatability: 0.5%
  • Rangeability: Varies from 5:1 to 10:1 depending on differential pressure.
  • Pressure Ratings: Max 25 Kg/Cm2.
  • Temperature Ratings: Max 121°C for gases, 93°C for liquids.
  • Connections: Flanged, with optional IP 55 or IP 65 enclosures.
Materials:
  • Mainline Orifice Plate: 316SS, 304SS, P.P.
  • Orifice Flange/Carrier Ring: M.S., 316SS, P.P.
  • Range Orifice: 316SS
  • Bypass Piping: M.S., 316SS
  • Glass Tube Rotameter: Borosilicate glass tube, SS 316/PTFE float.
  • Metal Tube Rotameter: SS 316/PTFE tube and float.
Capacity Tables: The document includes tables for liquid and gas flow capacities across various mainline sizes and differential pressures, indicating the versatility and adaptability of the rotameters for different applications.
Additional Information: The company, Flowtech Measuring Instruments Pvt. Ltd., provides calibration services and exports to multiple countries. They offer online calibration for flowmeter sizes 40 NB to 300 NB using high-accuracy ultrasonic flowmeters.
See more

Catalog excerpts

BYPASS ROTAMETER-1

BY –PASS GLASS TUBE ROTAMETER BY – PASS METAL TUBE ROTAMETER The simplest & most common flow meter is a fixed Orifice in a pipeline. This Orifice creates a pressure differential (i.e. pressure drop) which is proportional to flow. But the flow rate versus differential pressure is a square root function, thus at the high end of the scale the graduations are far apart and very easy to read. At the low end of the scale, the graduations are so close together that reading becomes impossible. The net result is a meter with only a 3 OR 4 to 1 usable range. The limited rangeability of this type of meter can be overcome by adding a bypass leg around the Orifice, which has a pressure drop equal to the drop across the Orifice and bypassed flow is directly proportional to the mainline flow. This results in a meter, which has a linear function and not a square root. Since the flow meter has a 10 to 1 range, the Orifice meter will now have a 10 to 1 linear flow range, which is as easy to read at the bottom as the top of the scale. This principle can be used virtually any pipeline size, handling almost any flow rate and metering either liquid OR gas. It is one of the most versatile meters available. Its only limitation is that the solid particles OR slurries can clog the Orifice and prevent proper operation. .

 Open the catalog to page 1
BYPASS ROTAMETER-2

The Bypass flow meter consists of a mainline Orifice plate, a set of Orifice Flanges Or a carrier ring, a flow meter, range Orifice, Bypass piping with Isolation Valves. (i) Mainline Orifice Plate:- The purpose of the mainline orifice plate is to create the pressure differential. As the flow rate varies across this mainline orifice, the pressure differential across this plate also varies and it is this variation, which makes the meter function. (ii) Orifice Flanges / Carrier Ring:- Orifice flanges / carrier rings serve two functions. First, they hold the mainline orifice plate in the proper position...

 Open the catalog to page 2
BYPASS ROTAMETER-3

MATERIALS OF CONSTRUCTION Mainline Orifice Plate : 316SS, 304SS, P.P. Orifice Flange / Carrier Ring : M.S., 316SS, P.P. Bypass Piping with Isolation Valves : M.S., 316SS Glass Tube Rotameter: -Tube Float Packing End Fitting Frame & Cover Metal Tube Rotameter:-Tube Float Packing End Fitting Borosilicate Glass SS 316, PTFE, others on request Neoprene, PTFE, Silicon, Viton M.S., C.S., SS304, SS316, CF-8M, CF8, C.I. PTFE Lined, SS PTFE Lined, PVC, others on request : M.S. OR SS SS 316, PTFE, others on request SS 316, PTFE, others on request Neoprene, PTFE, Silicon, Viton M.S., C.S., SS304, SS316,...

 Open the catalog to page 3
BYPASS ROTAMETER-4

CAPACITY TABLE - GLASS / METAL TUBE BY PASS ROTAMETER FOR GASES

 Open the catalog to page 4
BYPASS ROTAMETER-5

FLOWTECH MEASURING INSREUMNTS PVT. LTD. AN ISO 9001: 2015 COMPANY Works : 900/2/B, GIDC, Makarpura, Vadodara - 390010. Gujarat (India) Website : www.flowtech-instruments.com,www.flowtechinstruments.in Exporters to : BANGLADESH - DUBAI - EGYPT - FRANCE - INDONESIA - KUWAIT - MALAYSIA -NEPAL NIGERIA - POLAND - SARJAH - SINGAPORE - SRI LANKA - SOUTH AFRICA - THAILAND Local Dealers : AHMEDABAD - ANKLESHWAR - BHOPAL - CHENNAI - GANDHIDHAM HYDERABAD - INDORE - MUMBAI Note : DOING ONLINE CALIBRATION OF FLOWMETER SIZE 40 NB TO 300 NB THROUGH HIGH ACCURACY ULTRASONIC FLOWMETER AT SITE ON REQUEST.

 Open the catalog to page 5

Archived catalogs

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.