SIHILPH-X - Liquid Ring Vacuum Pump One Stage LPH 40106, LPH 40411, LPH 40516
12Pages

{{requestButtons}}

Catalog excerpts

SIHILPH-X - Liquid Ring Vacuum Pump One Stage LPH 40106, LPH 40411, LPH 40516 - 1

SIHILPH-X - Liquid Ring Vacuum Pump One Stage LPH 40106, LPH 40411, LPH 40516 VACUUM TECHNOLOGY LPH LI 2 133.71120.61.01 E 03/2008 Pressure Range: 150 to 1013 mbar Suction Range: 50 to 270 m³/h CONSTRUCTION Sterling SIHI liquid ring vacuum pumps have a simple but robust construction with the following features and benefits: Near isothermal compression Oil free, with no internal lubrication Capable of handling almost all gases and vapours Able to handle quantities of liquid “carry over” Low maintenance and safe operation Low noise and almost vibration free Available in a wide range of materials Broad range of applications O-ring sealing as standard Cavitation protection as standard Drain hole as standard Built-in solids drain Rotating metallic parts are non contacting to minimise wear ATEX compliance Sterling SIHI liquid ring vacuum pumps of the range LPH 40106, LPH 40411 and LPH 40516 are one stage pumps. They can be used as compressors up to a pressure of 1.2 bar without any modification (see the Technical Catalogue - Liquid Ring Compressors Part K). APPLICATIONS Evacuation and pumping of dry gases and saturated vapours. The pumps can also handle liquids. These units offer pressures in the range of 150…900 mbar(a) to atmospheric. Typical application areas include: Chemical and pharmaceutical industry for distillation, drying and degassing. Electronic industry for impregnation and drying. Plastics & Rubber industry for degassing. NOTE By continuously feeding the pump with a small amount of service liquid (usually water), the heat due to gas/vapour compression is conducted away. This also replenishes the liquid ring and ensures that it does not become saturated with process media. The condensed gas and fluid can be separated in a liquid separator (see Accessories Catalogue). Recharging the pump with service liquid at ambient temperature enables the unit to condense evacuated gases/vapours. It can therefore be used for solvent recovery. More information is provided in the accessory catalogues. The integrated solids drain permits the removal of any entrained solids whilst the pump is operating. The service liquid can, therefore, simply be recirculated. The rotation of the pump is clockwise when viewed from the drive end. GENERAL TECHNICAL DATA Pump Type Units LPH 40106 LPH 40411 LPH 40516 Speed 50 Hz 60 Hz rpm rpm 1450 1) 1740 Maximum overpressure on compression bar 0.8 1.5 1.5 Maximum permissible pressure difference bar 1.5 1.5 1.5 or 1.2 2) Water pressure test (Overpressure) bar 3.0 Moment of inertia of rotating parts of pump and of water content kg . m² 0.0375 0.05 0.065 Noise level at 200 mbar suction pressure dB (A) 65 Minimum permissible pulley diameter for V belt drive mm 160 Max. Gas temperature: dry saturated °C °C 240 120 Service liquid: Max. permissible temperature Max. viscosity Max. density °C mm²/s kg/m³ 100 90 1200 Liquid capacity up to middle of shaft litre 3.5 4.5 5.5 Maximum flow resistance of the heat exchange bar 0.2 In selecting a pump, avoid choosing one which is likely to be operating at a combination of its maximum permissible limits e.g. maximum viscosity and maximum permissible pressure difference. 1) Normal speed 2) With material execution 4B at 60Hz

Open the catalog to page 1
SIHILPH-X - Liquid Ring Vacuum Pump One Stage LPH 40106, LPH 40411, LPH 40516 - 2

SIHILPH-X 2 Materials Materials Position Number Component 0A 0B SZ 4B 10.60 Casing 0.6025 1.4408 10.90 Central Body 0.6025 1.4408 13.70 Guide Disc 0.6025 1.4404 23.50 Impeller 2.1096.01 1.0619 1.4517 21.00 Shaft 1.4021 1.4401 43.30, 43.31 Mechanical Seal, Type SIHI FK (AG•) Cr-Steel / Carbon / Butadiene rubber Cr Ni Mo-Steel / Carbon / Viton 43.30, 43.31 Mechanical Seal, Type Sterling GNZ (AF•) SiC / Carbon / Viton SiC / Carbon / Teflon 43.30, 43.31 Double Mechanical Seal on request Cut-away diagram LPH 40106, LPH 40411, LPH 40516 with single and double mechanical seal

Open the catalog to page 2
SIHILPH-X - Liquid Ring Vacuum Pump One Stage LPH 40106, LPH 40411, LPH 40516 - 3

SIHILPH-X 3 Performance Characteristics LPH 40106 0 20 40 60 80 100 120 100 1000 suction pressure suction volume flow 1450 rpm 1740 rpm m³/h 200 300 400 600 mbar LPH 40106 0 0,5 1 1,5 2 2,5 3 3,5 100 1000 suction pressure power absorption kW 1450 rpm 1740 rpm LPH 40106 200 300 400 600 mbar The operating data is valid under the following conditions: • Process media: - dry air: 20°C - steam saturated air: 20°C • Service liquid: - water: 15°C Pressure of gas to be evacuated: 1013 mbar (Atmospheric pressure) The suction volume is related to the suction pressure Tolerance for the suction volume...

Open the catalog to page 3
SIHILPH-X - Liquid Ring Vacuum Pump One Stage LPH 40106, LPH 40411, LPH 40516 - 4

SIHILPH-X 4 Performance Characteristics LPH 40411 0 25 50 75 100 125 150 175 200 100 1000 suction pressure suction volume flow 1450 rpm 1740 rpm m³/h 200 300 400 600 mbar LPH 40411 0 0,5 1 1,5 2 2,5 3 3,5 4 4,5 5 100 1000 suction pressure power adsorption kW 1450 rpm 1740 rpm LPH 40411 200 300 400 600 mbar The operating data is valid under the following conditions: • Evacuated medium: - dry air: 20°C - steam saturated air: 20°C • Working liquid: - water: 15°C Pressure of gas to be evacuated: 1013 mbar (Atmospheric pressure) The suction volume is related to the suction pressure Tolerance for...

Open the catalog to page 4
SIHILPH-X - Liquid Ring Vacuum Pump One Stage LPH 40106, LPH 40411, LPH 40516 - 5

SIHILPH-X 5 Performance Characteristics LPH 40516 0 50 100 150 200 250 300 100 1000 suction pressure suction volume flow 1450 rpm 1740 rpm m³/h 200 300 400 600 mbar LPH 40516 0 1 2 3 4 5 6 7 100 1000 suction pressure power adsorption kW 1450 rpm 1740 rpm LPH 40516 200 300 400 600 mbar The operating data is valid under the following conditions: • Evacuated medium: - dry air: 20°C - steam saturated air: 20°C • Working liquid: - water: 15°C Pressure of gas to be evacuated: 1013 mbar (Atmospheric pressure) The suction volume is related to the suction pressure Tolerance for the suction volume...

Open the catalog to page 5
SIHILPH-X - Liquid Ring Vacuum Pump One Stage LPH 40106, LPH 40411, LPH 40516 - 6

SIHILPH-X 6 Dimensions LPH 40106, LPH 40411, LPH 40516 with single mechanical seal 1) = Connection on both sides is only necessary for LPH 40516 N 1 = Gas-Inlet DN 40 N 2 = Gas-Outlet DN 40 uB = Connection for Service Liquid G 1/2 ue = Connection for Drain G 1/8 use = Connection for Dirt Drain G 1/8 uL = Connection for Air Cock G 1/2 um = Connection for Pressure Gauge G 1/4 um1 = Connection for Drainage Valve or Liquid Level Sensor G 1/4 a m1 m2 o3 Approx. Weight [mm] [mm] [mm] [mm] [kg] LPH 40106 144 258 204 431 55 LPH 40411 194 308 254 481 60 LPH 40516 244 358 304 531 65

Open the catalog to page 6