SIHIcompact - Vacuum Compact Units
12Pages

{{requestButtons}}

Catalog excerpts

SIHIcompact - Vacuum Compact Units - 1

CONSTRUCTION The SIHIcompart vacuum units consist of various components which are assembled together to form a compact unit with an optional function range. The LEM liquid ring vacuum pump utilised in these units is of a single stage design and of a simple and robust construction with the following features: • Non polluting due to near isothermal compression • Oil free, no lubrication in the working chamber • Capable of handling nearly all gases and vapours • Small quantities of entrained liquid can be handled • Easy to maintain and reliable operation • Low noise and virtually free from vibration • Cavitation protection as standard The SIHIcomparf vacuum units are produced as a service liquid saving arrangement and can be supplied with or without a heat exchanger. APPLICATION For handling dry and saturated forms of gases. Small quantities of entrained liquid in the suction gas stream can also be dealt with. The SIHIcompart is designed for vacuum applications of between 33 and 900 mbar. This range can be extended when used in conjunction with the respective gas operated ejector (up to 8 mbar). During its operation, the liquid ring vacuum pump must be continuously supplied with service liquid, normally water, in order to eliminate the heat resulting from the gas compression and to prevent the pump from dry running operation. The service liquid is separated from the process gas in a separator. Depending on the chosen arrangement and application the service liquid can be either totally or partially re-used within the system (combined- or circulating operation). In the case of circulating operation with heat exchanger the pressure difference between the suction inlet and discharge outlet should be 200 mbar at minimum. The direction of rotation is clockwise when viewed from the drive end of the pump. The combination of several limiting values is not admissible.

Open the catalog to page 1
SIHIcompact - Vacuum Compact Units - 2

Operating mode: Circulating operation - Type H Operating mode: Combined operation, thermostatic control - Type T Operating mode: Combined liquid operation - Type C Connections

Open the catalog to page 2
SIHIcompact - Vacuum Compact Units - 3

Voltage for 2/2-ways solenoid valve, 24 V DC, combined operation Other material combinations upon request Not in combination with gas ejector rsp. vacuum relief valve

Open the catalog to page 3
SIHIcompact - Vacuum Compact Units - 4

Material design of the pump Standard design LEM 26, 51, 91, 126, 161,251

Open the catalog to page 4
SIHIcompact - Vacuum Compact Units - 5

SIHIcompact Suction volume flow and power absorption 40 suction volume flow suction volume flow suction pressure suction pressure power adsorption suction pressure suction volume flow suction volume flow suction pressure suction pressure suction pressure power adsorption suction pressure The operating data are applicable under the following conditions:  Pumping medium: - dry air: - saturated air:  Service liquid: - water: Discharge pressure: 1013 mbar (atmospheric pressure) Tolerance of the operating data 10% suction pressure

Open the catalog to page 5
SIHIcompact - Vacuum Compact Units - 6

SIHIcompact Suction volume flow and power absorption 240 suction volume flow suction volume flow power adsorption suction pressure suction pressure suction volume flow suction volume flow suction pressure suction pressure power adsorption suction pressure suction pressure power adsorption power adsorption suction pressure The operating data are applicable under the following conditions:  Pumping medium: - dry air: - saturated air:  Service liquid: - water: Discharge pressure: 1013 mbar (atmospheric pressure) Tolerance of the operating data 10% suction pressure

Open the catalog to page 6
SIHIcompact - Vacuum Compact Units - 7

Connections Operating mode: Circulating operation - Type H N2 'T'

Open the catalog to page 7
SIHIcompact - Vacuum Compact Units - 8

Make-up liquid consumption in [m3/h] dependent upon suction pressure, speed, drive type and temperature difference FB = Total service liquid flow rate on once-through system KB = Flow of make-up water when combined with partial recirculation liquid at a temperature of 10°C, 5°C, 2°C, warmer than make-up water

Open the catalog to page 8
SIHIcompact - Vacuum Compact Units - 9

Operating mode: Circulating operation - Type H, Material design: Basic - Type 0 Flange connections accord to DIN EN 1092-1 PN 10 [mm]

Open the catalog to page 9
SIHIcompact - Vacuum Compact Units - 10

Operating mode: Combined operation - Type C / T, Material design: Basic - Type 0 Flange connections Flange connections accord to DIN EN 1092-1 PN 10 [mm]

Open the catalog to page 10
SIHIcompact - Vacuum Compact Units - 11

Structure of the type code Example: Size PLC 161 PLC B 161 H D S 4 NP 00 1A Design version Size Operating mode Connection Execution Material design Precompression Options Motor code Version Standard delivery program For our products we offer a lot of different motor types. To identify the right motor please specify frequency, voltage and protection class. Designs subject to change without prior notice.

Open the catalog to page 11