Group: Flowserve
Catalog excerpts

CONSTRUCTION The SIHIcompart vacuum units consist of various components which are assembled together to form a compact unit with an optional function range. The LEM liquid ring vacuum pump utilised in these units is of a single stage design and of a simple and robust construction with the following features: • Non polluting due to near isothermal compression • Oil free, no lubrication in the working chamber • Capable of handling nearly all gases and vapours • Small quantities of entrained liquid can be handled • Easy to maintain and reliable operation • Low noise and virtually free from vibration • Cavitation protection as standard The SIHIcomparf vacuum units are produced as a service liquid saving arrangement and can be supplied with or without a heat exchanger. APPLICATION For handling dry and saturated forms of gases. Small quantities of entrained liquid in the suction gas stream can also be dealt with. The SIHIcompart is designed for vacuum applications of between 33 and 900 mbar. This range can be extended when used in conjunction with the respective gas operated ejector (up to 8 mbar). During its operation, the liquid ring vacuum pump must be continuously supplied with service liquid, normally water, in order to eliminate the heat resulting from the gas compression and to prevent the pump from dry running operation. The service liquid is separated from the process gas in a separator. Depending on the chosen arrangement and application the service liquid can be either totally or partially re-used within the system (combined- or circulating operation). In the case of circulating operation with heat exchanger the pressure difference between the suction inlet and discharge outlet should be 200 mbar at minimum. The direction of rotation is clockwise when viewed from the drive end of the pump. The combination of several limiting values is not admissible.
Open the catalog to page 1
Operating mode: Circulating operation - Type H Operating mode: Combined operation, thermostatic control - Type T Operating mode: Combined liquid operation - Type C Connections
Open the catalog to page 2
Voltage for 2/2-ways solenoid valve, 24 V DC, combined operation Other material combinations upon request Not in combination with gas ejector rsp. vacuum relief valve
Open the catalog to page 3
Material design of the pump Standard design LEM 26, 51, 91, 126, 161,251
Open the catalog to page 4
SIHIcompact Suction volume flow and power absorption 40 suction volume flow suction volume flow suction pressure suction pressure power adsorption suction pressure suction volume flow suction volume flow suction pressure suction pressure suction pressure power adsorption suction pressure The operating data are applicable under the following conditions: Pumping medium: - dry air: - saturated air: Service liquid: - water: Discharge pressure: 1013 mbar (atmospheric pressure) Tolerance of the operating data 10% suction pressure
Open the catalog to page 5
SIHIcompact Suction volume flow and power absorption 240 suction volume flow suction volume flow power adsorption suction pressure suction pressure suction volume flow suction volume flow suction pressure suction pressure power adsorption suction pressure suction pressure power adsorption power adsorption suction pressure The operating data are applicable under the following conditions: Pumping medium: - dry air: - saturated air: Service liquid: - water: Discharge pressure: 1013 mbar (atmospheric pressure) Tolerance of the operating data 10% suction pressure
Open the catalog to page 6
Connections Operating mode: Circulating operation - Type H N2 'T'
Open the catalog to page 7
Make-up liquid consumption in [m3/h] dependent upon suction pressure, speed, drive type and temperature difference FB = Total service liquid flow rate on once-through system KB = Flow of make-up water when combined with partial recirculation liquid at a temperature of 10°C, 5°C, 2°C, warmer than make-up water
Open the catalog to page 8
Operating mode: Circulating operation - Type H, Material design: Basic - Type 0 Flange connections accord to DIN EN 1092-1 PN 10 [mm]
Open the catalog to page 9
Operating mode: Combined operation - Type C / T, Material design: Basic - Type 0 Flange connections Flange connections accord to DIN EN 1092-1 PN 10 [mm]
Open the catalog to page 10
Structure of the type code Example: Size PLC 161 PLC B 161 H D S 4 NP 00 1A Design version Size Operating mode Connection Execution Material design Precompression Options Motor code Version Standard delivery program For our products we offer a lot of different motor types. To identify the right motor please specify frequency, voltage and protection class. Designs subject to change without prior notice.
Open the catalog to page 11All Flowserve SIHI Pumps catalogs and technical brochures
-
Type NHK and SHK
24 Pages
-
SIHIsanivac 400, 800, 1000
4 Pages
-
PL 325 M
14 Pages
-
PL 91 M, PL 126 M, PL 161 M
16 Pages
-
SIHI ® Gas separation
8 Pages
-
SIHI Liquid Ring Compressors
8 Pages
-
Side Channel Pumps
12 Pages
-
LPG Solutions
12 Pages
-
SIHISuperNova ZHND 032160
14 Pages
-
SIHImodular PL 251 M
13 Pages
-
LEM 26, LEM 51
7 Pages
-
LEM 325, LEM 425
8 Pages
-
Applications and Products
9 Pages
-
Series MFS, 7,200 m³/h
2 Pages
-
Sludge Mixer MFS
2 Pages
-
Mixed Flow, Volute Casing Pump
11 Pages
-
Volute casing pumps
26 Pages
-
Non-clogging Pump
19 Pages
-
Volute casing pump CBT
11 Pages