Catalogue - Series SIHISuperNova ZDN, 600 m³/h, 90 m, 207 °C
14Pages

{{requestButtons}}

Catalog excerpts

Catalogue - Series SIHISuperNova ZDN, 600 m³/h, 90 m, 207 °C - 1

Volute pumps TECHNICAL DATA Delivery head: Casing pressure: Shaft sealing: Flange connections: balanced standard mechanical seal, clockwise, when looking at the Pump from the drive end The volute pumps of the series ZDHD are part of the overall programme heat transfer and circulation pumps. They are primarily used for circulation of hot water in closed pipe and vessel systems. Therefore their fields of application are and here mainly in systems where hot water as heat carrier is given preference, despite is high system pressure, over oil as heat carrier. Horizontal, single-stage volute casing pumps with the dimensions ans nominal ratings to DIN EN 22858 in back pull out design, with uncooled balanced mechanical seal. The series ZDND has especially been designed for the trouble free handling of hot water up to 207 °C and is distinguished by: • A double heat barrier that causes an optimal energy consumption by the pump and reduces the temperature level in the mechanical seal chamber to less than 90 °C without external cooling circuit (see temperature curve on page 3). The service life of the mechanical seal increases considerably. • A special design that automatically leads accumulation of gas to exhaust. Consequently the dry operation of the mechanical seal • A programme that comprehends 22 construction sizes and thus guarantees an optimal solution for every operating point. • The back pull out design, which permits the removal of the complete, bearing unit towards the drive side without removing the pump casing from the pipe work. If a spacer coupling is installed it is also unnecessary to disconnect the motor. Casing pressure Please note: Technical rules and safety regulations. Casing pressure = inlet pressure + zero head Flanges location: Axial suction flange, discharge flange radially upwards. The flanges comply with DIN EN 1092-2 resp. PN 40. Flange design to ANSI 300 is possible. Designation of this construction type: A One grease lubricated antifriction ball bearing to DIN 625 and one internal liquid flushed sleeve bearing. Designation of this construction type: A Clockwise when looking at the pump from the drive end. Shaft sealing: Code AF3: Balanced standard mechanical seal Seal face materials SIC/Carbon, Elastomer

Open the catalog to page 1
Catalogue - Series SIHISuperNova ZDN, 600 m³/h, 90 m, 207 °C - 2

Material Design: Casing gasket: The casing is sealed by a flat gasket of graphite. Designation of this construction type: 2 Motor power: Using commercial electric motors, type of construction IM B3. To determine the drive power we recommend the following safety margin: The following max. speeds are to be observed: The max. speeds results from the admissible peripheral speed of impellers or from the shaft load admissible at higher temperatures, Bearing bracket / pump size: General remarks: For equipping hot media systems a complete programme is available for a flow range between 1-1000 m3/h...

Open the catalog to page 2
Catalogue - Series SIHISuperNova ZDN, 600 m³/h, 90 m, 207 °C - 3

Sectional drawing and nomenclature 44.10 casing for mechanical seal Heat barrier / shaft seal / bearing / feet arrangement Heat transfer installations have achieved a high level of technical development. Consequently the requirements on the pumps handling heat carriers have increased regarding operating safety, environmental protection, maintenance and operating costs. On the basis of many years' experience and latest technical know-how the ZDND fully complies with these requirements. Special attention was paid to the above technical A favourable reduction in temperature is obtained towards...

Open the catalog to page 3
Catalogue - Series SIHISuperNova ZDN, 600 m³/h, 90 m, 207 °C - 5

Performance graph

Open the catalog to page 5
Catalogue - Series SIHISuperNova ZDN, 600 m³/h, 90 m, 207 °C - 6

Uv= vent connection (G1/8) Us, = grease filling connection (G1/8) 'Transnorm pump sizes, not included in DIN EN 22858. 'Slots suitable for bolts with dimensions indicated. Bolts are not included in the bare shaft pump standard scope of supply.

Open the catalog to page 6
Catalogue - Series SIHISuperNova ZDN, 600 m³/h, 90 m, 207 °C - 7

* Motor protection type IP 55, dimensions depend on Some sizes are not corresponding to the drawing in small details. Foundation plan for 60Hz on request.

Open the catalog to page 7
Catalogue - Series SIHISuperNova ZDN, 600 m³/h, 90 m, 207 °C - 8

Foundation plan * Motor protection type IP 55, dimensions depend on Some sizes are not corresponding to the drawing in small details. Foundation plan for 60Hz on request.

Open the catalog to page 8
Catalogue - Series SIHISuperNova ZDN, 600 m³/h, 90 m, 207 °C - 9

* Motor protection type IP 55, dimensions depend on the motor manufacturer. Some sizes are not corresponding to the drawing in small details. Foundation plan for 60Hz on request.

Open the catalog to page 9
Catalogue - Series SIHISuperNova ZDN, 600 m³/h, 90 m, 207 °C - 10

Foundation plan for units with spacer coupling * Motor protection type IP 55, dimensions depend on the motor manufacturer. Some sizes are not corresponding to the drawing in small details. Foundation plan for 60Hz on request.

Open the catalog to page 10
Catalogue - Series SIHISuperNova ZDN, 600 m³/h, 90 m, 207 °C - 11

* Motor protection type IP 55, dimensions depend on the motor manufacturer. Some sizes are not corresponding to the drawing in small details. Foundation plan for 60Hz on request.

Open the catalog to page 11
Catalogue - Series SIHISuperNova ZDN, 600 m³/h, 90 m, 207 °C - 12

Foundation plan for units with spacer coupling * Motor protection type IP 55, dimensions depend on the motor manufacturer. Some sizes are not corresponding to the drawing in small details. Foundation plan for 60Hz on request.

Open the catalog to page 12
Catalogue - Series SIHISuperNova ZDN, 600 m³/h, 90 m, 207 °C - 13

Data regarding pump size Any changes in the interest of the technical development are reserved.

Open the catalog to page 13
Catalogue - Series SIHISuperNova ZDN, 600 m³/h, 90 m, 207 °C - 14

Sterling SIHI GmbH

Open the catalog to page 14

All Flowserve SIHI Pumps catalogs and technical brochures