Overview: The DataKeep 300500 XP Level Indicator is a CSA-approved explosion-proof loop-powered level indicator designed for hazardous environments. It features a modern design with easy readability and enhanced functionality, displaying engineering units connected in series with a 4-20 mA continuous level transmitter.
Key Features:
  • Aluminum XP windowed enclosure with dual conduit ports.
  • LCD display indicating engineering units and descriptors.
  • Non-volatile memory with security password.
  • SafeTouch through-glass button programming.
  • 32-point, square root, or exponential linearization.
Specifications:
  • Display Type: Upper LCD 5 digits, Lower 7 characters.
  • Display Units: Engineering units such as inches, feet, meters, gallons, and liters.
  • Display Output: 0.001 to 99,999.
  • Display Height: Main 0.70” (18mm), Secondary 0.4” (10mm).
  • Configuration: Push button/SafeTouch through-glass.
  • Memory: Non-volatile.
  • Sensor Input: (1) 4-20 mA transmitter.
  • Loop Power: 9-30 VDC.
  • Voltage Drop: 3.0 VDC @ 20 mA without backlight, 6.0 VDC @ 20 mA with backlight.
  • Ambient Temperature: -40° to 167°F (-40° to 75°C).
  • Enclosure Rating: NEMA 4X, 7 & 9 (IP68).
  • Enclosure Material: Aluminum.
  • Window Material: Glass.
  • Conduit Entrance: Dual, 3/4” NPT.
  • Classification: Explosion proof.
  • Compliance: CE.
  • Approvals: FM, ATEX, IECEx, CSA.
Applications: Ideal for use in classified, explosion-proof applications, the level indicator is suitable for corrosive, ultrapure, sticky, or dirty liquids. It is widely used in bulk storage, day tanks, lift stations, and process tank level applications located in classified areas.
Compatible Products: The level indicator is compatible with the EchoSafe Ultrasonic Level Transmitter, which provides continuous level measurement up to 32.8’ (10m) with a 4-20 mA signal output.
Ordering Information: For explosion-proof level indication, package the level indicator with the EchoSafe transmitter. Recommended power supply: AC-DC Sensor & Indicator Power Supply LC95-2001 (100-240 VAC, 24 VDC @ 0.60A, 35mm Rail).
See more

Catalog excerpts

DataKeep? XP Level Indicator-1

DataKeep™ 300500 XP Level Indicator Application CSA approved explosion proof loop powered level indicator brings modern design, easy readability and enhanced functionality to hazardous environments displaying engineering units connected in series with one 4-20 mA, continuous level transmitter. Select this level indicator for hazardous applications with an explosion proof level sensor. The windowed field enclosure is wall mounted. Aluminum XP windowed enclosure with dual conduit ports LCD display indicates engineering units and descriptors SafeTouch through-glass button programming 32-point, square root or exponential linearization Simple loop powered display for use in classified, explosion proof applications Add display to current loop in the classified area Displays in the following engineering units: inches, feet, meters, gallons, and liters of liquid Easy to configure and scale Non-volatile memory with security password Compatible Products EchoSafe® Ultrasonic Level Transmitter FM approved for hazardous environments, the explosion proof ultrasonic level transmitter provides continuous level measurement up to 32.8’ (10m) with a 4-20 mA signal output, and is configured via the integral push button display module. This non-contact liquid level sensor is ideally suited for corrosive, ultrapure, sticky or dirty liquids, and is widely selected for bulk storage, day tank, lift station and process tank level applications located in a classified area. © 2013 Flowline Inc. • 10500 Humbolt Street Los Alamitos, CA 90720 • 562.598.3015 • www.flowline.com • DS300500 REV A

 Open the catalog to page 1
DataKeep? XP Level Indicator-2

DataKeep™ 300500 XP Level Indicator Dimensions Specifications Display type: Lower: 7 characters Engineering Display height: Main: 0.70” (18mm) Decimal point: Push button / SafeTouch Display units: Sensor input: Loop power: Voltage drop: AC-DC Sensor & Indicator Power Supply with loop-powered backlight Accessories For enhanced flexibility and performance, use the below recommended power supply. Enclosure rating: NEMA 4X, 7 & 9 (IP68) Enclosure mat’l.: Aluminum Window mat’l.: Glass Conduit entrance: Dual, 3/4” NPT Classification: Explosion proof Notes Ordering Notes 1) For explosion proof proof...

 Open the catalog to page 2
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.