FLOWAIR GŁOGOWSKI I BRZEZIŃSKI SP.J. ul. Chwaszczyńska 135, 81-571 Gdynia T: +48 (58) 669 82 20 www.flowair.com CATALOGUE CARD KM S | L | XL KARTA KATALOGOWA KM S | L | XL GENERAL INFORMATION | INFORMACJE OGÓLNE EN     It is designed for delivering fresh air to the room. KM S mixing chamber is dedicated to operate with LEO S units. KM L mixing chamber is dedicated to operate with LEO L. KM XL mixing chamber is dedicated to operate with LEO XL units. Easy to mount thanks to small size and weight. Mixing chamber is equipped with filter coarse 80% class (PN-EN ISO 16890-1E). Steel casing. Umożliwia ona dostarczenie świeżego (zewnętrznego) powietrza do pomieszczenia. Komora mieszania KM S przystosowana jest do współpracy z nagrzewnicami powietrza LEO S. Komora mieszania KM L przystosowana jest do współpracy z nagrzewnicami powietrza LEO L. Komora mieszania KM XL przystosowana jest do współpracy z nagrzewnicami powietrza LEO XL. Standardowo komora wyposażona jest w filtr kasetowy klasy coarse 80% (PN-EN ISO 16890-1E). Możliwa jest filtracja powietrza zewnętrznego i recyrkulacyjnego lub tylko zewnętrznego. Komora dostępna jest w wykonaniu z blachy ocynkowanej. CONTROL SYSTEM KM I AUTOMATYKA KM    Regulation of dampers depends on outside air temperature | regulacja przepustnic względem temperatury zewnętrznej smooth regulation of supplied air temperature |kontrola temperatury powietrza nawiewanego do pomieszczenia balance, overpressure or underpressure to roof fans | bilans, nadciśnienie lub podciśnienie względem wentylatorów dachowych antifreeze protection | ochrona przeciwzamrożeniowa urządzenia possibility of connection to BMS | możliwość podłączenia do BMS possibility to connect gas detection unit | możliwość pracy względem czujnika CO2 lub wilgoci integration with Flowair System | integracja do Systemu Flowair INSTALLATION I MOŻLIWOŚĆ MONTAŻU A S1 + KM S S2 + KM S S3 + KM S L1 + KM L L2 + KM L L3 + KM L XL2 + KM XL XL3 + KM XL (1) For air blades installed vertically. When mounting under a ceiling, the mounting height should be selected depending on the non-isothermal vertical range.| Przy pionowym ułożeniu kierownic powietrza. Przy montażu podstropowym wysokość mont

 Open the catalog to page 1
CATALOGUE CARD KM S | L | XL-2

TECHNICAL DATA I DANE TECHNICZNE LEO S1 I S2 I S3 + KM S Max airflow [m3/h ]* | Max. strumień przepływu powietrza [m3/h ]* Power supply [V/Hz] | Zasilanie [V/Hz] Max current consumption [A] | Max. pobór prądu [A] Max power consumption [W] | Max. pobór mocy [W] | IP/ Insulation class | IP/Klasa izolacji Max acoustic pressure level [dB(A)]** | Max. poziom ciśnienia akustycznego [dB(A)] ** Horizontal range*** [m] | Zasięg poziomy*** [m] Vertical range**** [m] | Zasięg pionowy**** [m] Max heating water temperature [ C] | Max. temp. wody grzewczej [oC] Max operating pressure [MPa] | Max. ciśnienie...

 Open the catalog to page 2
CATALOGUE CARD KM S | L | XL-3

TECHNICAL DATA I DANE TECHNICZNE LEO L1 I L2 I L3 + KM L Max airflow [m3/h ]* | Max. strumień przepływu powietrza [m3/h ]* Power supply [V/Hz] | Zasilanie [V/Hz] Max current consumption [A] | Max. pobór prądu [A] Max power consumption [W] | Mak. pobór mocy [W] | IP/ Insulation class | IP/Klasa izolacji Max acoustic pressure level [dB(A)] | Max. poziom ciśnienia akustycznego [dB(A)] ** Horizontal range*** [m] | Zasięg poziomy*** [m] Vertical range**** [m] | Zasięg pionowy**** [m] Max heating water temperature [oC] | Max. temp. wody grzewczej [oC] Max operating pressure [MPa] | Max. ciśnienie robocze...

 Open the catalog to page 3
CATALOGUE CARD KM S | L | XL-4

TECHNICAL DATA I DANE TECHNICZNE LEO XL2 I XL3 + KM XL Max airflow [m3/h ]* | Max. strumień przepływu powietrza [m3/h ]* Power supply [V/Hz] | Zasilanie [V/Hz] Max current consumption [A] | Max. pobór prądu [A] Max power consumption [W] | Mak. pobór mocy [W] | IP/ Insulation class | IP/Klasa izolacji Max acoustic pressure level [dB(A)] | Max. poziom ciśnienia akustycznego [dB(A)] ** Horizontal range*** [m] | Zasięg poziomy*** [m] Vertical range**** [m] | Zasięg pionowy**** [m] Max heating water temperature [oC] | Max. temp. wody grzewczej [oC] Max operating pressure [MPa] | Max. ciśnienie robocze...

 Open the catalog to page 4
CATALOGUE CARD KM S | L | XL-5

HEATING CAPACITY I TABELE MOCY GRZEWCZYCH LEO S1 + KM S Tp1 III : V = 1200 [m³/h], 100 % fresh air | 100 % świeżego powietrza -25,0 III : V = 1100 [m³/h], 100 % fresh air | 100 % świeżego powietrza -25,0 V - airflow | przepływ powietrza PT - heat capacity | moc grzewcza Tp1 - inlet air temp. | temperatura powietrza na wlocie do aparatu Tp2 - outlet air temp. | temperatura powietrza na wylocie z aparatu * Too low air temperature at the outlet of the device | Zbyt niska temperatura powietrza na wylocie z urządzenia Tw1 - inlet water temp. | temperatura wody na zasilaniu wymiennika Tw2 - outlet...

 Open the catalog to page 5
CATALOGUE CARD KM S | L | XL-6

III : V = 1000 [m³/h], 100 % fresh air | 100 % świeżego powietrza -25,0 III : V = 2600 [m³/h], 100 % fresh air | 100 % świeżego powietrza -25,0 V - airflow | przepływ powietrza Tw1 - inlet water temp. | temperatura wody na zasilaniu wymiennika PT - heat capacity | moc grzewcza Tw2 - outlet water temp. | temperatura wody na powrocie z wymiennika Tp1 - inlet air temp. | temperatura powietrza na wlocie do aparatu Qw - water flow rate | strumień przepływu wody grzewczej Tp2 - outlet air temp. | temperatura powietrza na wylocie z aparatu Δpw - pressure drop of water | spadek ciśnienia wody w wymienniku...

 Open the catalog to page 6
CATALOGUE CARD KM S | L | XL-7

III : V = 2400 [m³/h], 100 % fresh air | 100 % świeżego powietrza -25,0 III : V = 2250 [m³/h], 100 % fresh air | 100 % świeżego powietrza -25,0 V - airflow | przepływ powietrza PT - heat capacity | moc grzewcza Tp1 - inlet air temp. | temperatura powietrza na wlocie do aparatu Tp2 - outlet air temp. | temperatura powietrza na wylocie z aparatu * Too low air temperature at the outlet of the device | Zbyt niska temperatura powietrza na wylocie z urządzenia Tw1 - inlet water temp. | temperatura wody na zasilaniu wymiennika Tw2 - outlet water temp. | temperatura wody na powrocie z wymiennika Qw -...

 Open the catalog to page 7
CATALOGUE CARD KM S | L | XL-8

III : V = 3700 [m³/h], 100 % fresh air | 100 % świeżego powietrza -25,0 III : V = 3100 [m³/h], 100 % fresh air | 100 % świeżego powietrza -25,0 V - airflow | przepływ powietrza PT - heat capacity | moc grzewcza Tp1 - inlet air temp. | temperatura powietrza na wlocie do aparatu Tp2 - outlet air temp. | temperatura powietrza na wylocie z aparatu Tw1 - inlet water temp. | temperatura wody na zasilaniu wymiennika Tw2 - outlet water temp. | temperatura wody na powrocie z wymiennika Qw - water flow rate | strumień przepływu wody grzewczej Δpw - pressure drop of water | spadek ciśnienia wody w wymienniku...

 Open the catalog to page 8