Introduction to LEO Fan Heaters
The document introduces the LEO series of fan heaters, designed for air heating and ventilation. These heaters offer enhanced functionality and are available in eleven customizable versions, verified by international testing labs.
Device Specifications
LEO heaters are available in three casing options: EPP (standard), RAL (powder painted), and INOX (stainless steel). They offer a range of airflows and heating powers, with parameters confirmed by accredited labs, ensuring reliable performance.
Technical Parameters
The heaters have a heating capacity of 0.7–121 kW, air flow of 1000–5800 m3/h, and weigh between 9.5–26.2 kg. They are suitable for industrial halls, warehouses, and smaller rooms.
Installation and Mounting
LEO heaters can be installed vertically or on ceilings with rotary consoles and optional corner holders. The document specifies recommended installation distances and air stream direction settings.
Control Systems
Control options include the basic TS controller, advanced HMI controller, and intelligent T-box controller, offering manual and automatic air flow regulation and integration with the FLOWAIR system.
Comparison and Benefits
The document compares LEO solutions, highlighting features like 3-speed fans and intelligent control options. Benefits include cost-effectiveness, easy connection, and energy savings.
Conclusion
LEO fan heaters provide versatile and reliable air heating and ventilation solutions, with customizable options and advanced control systems for efficient operation.
Overview: The document details specifications and installation guidelines for LEO fan heaters and destratificators, designed to improve air distribution and heating efficiency in various settings.
Specifications: LEO fan heaters are available in models with varying air flow rates, heat power, and power consumption, constructed from powder-painted steel for ceiling mounting.
Mixing Chamber and Confusor: The LEO KM mixing chamber, combined with fan heaters, forms a heating and ventilation unit. The confusor enhances air distribution to lower zones.
Installation Guidelines: Emphasizes proper ceiling mounting and recommended installation distances, with brackets for easy installation.
Destratificators: Designed to prevent warm air accumulation in upper zones, redirecting it to occupied areas to improve heating efficiency.
Automatic Destratification System: Offers energy savings by redirecting warm air from upper to lower zones, integrating with the FLOWAIR system for enhanced control.
Integration and Control: The FLOWAIR system allows device integration with a single controller, offering advanced features like local regulation and antifreeze protection.
Heating Capacities: Tables provide heating capacities for various models under different temperature conditions.
Data Summary:
  • LEO L3 NP: Volume flow rate is 3400 m3/h.
  • LEO XL3 NP: Volume flow rate is 5300 m3/h.
Contact Information: Includes contact details for inquiries, with an address in Gdynia, Poland, and an email ([email protected]).
Version Information: Labeled as version 0.1/2023, indicating a preliminary version from 2023.
See more

Catalog excerpts

AIR HEATING AND VENTILATION Fan heaters LEO-1

AIR HEATING AND VENTILATION F heaters LEO an

 Open the catalog to page 1
AIR HEATING AND VENTILATION Fan heaters LEO-2

NEW SERIES OF LEO HEATERS Adapted to your needs For us a fan heater is not enough! That’s why we have created a new series of LEO fan heaters with greater functionality and better parameters confirmed by an international, accredited testing lab. Choose one of eleven versions which you can adjust in terms of heating power, temperature, range and noise level CHOOSE ONE OF ELEVEN Range of heating power at given parameters: min. – I step of fan, temperature of heating medium 40/30oC, air temperature at the supply to the device 20oC max. – III step of fan, temperature of heating medium 120/90oC, air...

 Open the catalog to page 2
AIR HEATING AND VENTILATION Fan heaters LEO-3

QUALITY LABEL / ETYKIETA JAKOŚCI LEO L2 Acoustic pressure level has been measured at max. airflow, 5 m from the unit, in a 1500 m3 space with a medium sound absorption coefficient. QUALITY LABEL / ETYKIETA JAKOŚCI LEO L2 Acoustic pressure level has been measured at max. airflow, 5 m from the unit, in a 1500 m3 space with a medium sound absorption coefficient. Heat power, at max. airflow, when the heating medium of 70/50oC, air temperature at the supply 16oC. Moc grzewcza, przy max. wydajności, czynniku grzewczym 70/50oC, temp. powietrza na wlocie 16oC. Verwarmingvermogen bij maximale ventilatiehoeveelheid...

 Open the catalog to page 3
AIR HEATING AND VENTILATION Fan heaters LEO-4

FAN HEATERS LEO Heating capacity [kW] (expanded polypropylene) AVAILABLE TYPES OF UNITS: APPLICATION LEO BMS LEO BMS fan heater is equipped with energy efficient 3 speed fans controlled by the DRV module. The DRV module manages the operation of devices according to control signals from T-Box or directly from BMS. Big cubature buildings: industrial halls, warehouses, department stores, production halls, sports halls, sacral buildings, etc., as well as smaller rooms, like: workshops, garages, stores, car show rooms, gas stations, etc. LEO LEO fan heater with AC fan offers possibility to switch...

 Open the catalog to page 4
AIR HEATING AND VENTILATION Fan heaters LEO-5

INSTALLATION AND VARIOUS MOUNTING POSSIBILITIES Possibility of setting the direction of air stream installation under the ceiling vertical installation using the console When device is mounted under the ceiling please note the proper nonisothermal air stream range Optional corner holders There are corner brackets available which make installation and levelling of the heater easier. Rotary console It enables installation of the heater perpendicularly or horizontally at various angles to the partition. RECOMMENDED INSTALLATION DISTANCE [M] S1

 Open the catalog to page 5
AIR HEATING AND VENTILATION Fan heaters LEO-6

COMPARE LEO SOLUTIONS When you need a simple solution Intelligent solutions compatible with FLOWAIR SYSTEM • the cheapest offer on the market (as a kit) • easy connection • 3-speed manual efficiency control Basic line intelligent sollutions and energy savings controls up to 31 devices compatible with the FLOWAIR SYSTEM BMS control local regulation • 3-speed automatic efficiency control • easy connection SET Fan heater LEO • 3 speed fan • light and durable EPP casing • wide range of heating power 0,7-121 kW Fan heater LEO • 3 speed fan • light and durable EPP casing • wide range of heating power...

 Open the catalog to page 6
AIR HEATING AND VENTILATION Fan heaters LEO-7

Heating capacity [kW] Nominal heat power (70/50/16oC, III step) [kW] Max. acoustic pressure level [dB(A)] Max. acoustic power level [dB(A)](2) Max. heating water temperature [ C] Weight of unit filled with water [kg] Acoustic pressure level at the distance of 5 m from the unit, in the room of medium capability of sound absorption and 1500 m of cubature In accordance with PN-EN ISO3744 (3) Range of horizontal isothermal air stream, at 0,5 m/s velocity limit (4) Range of vertical nonisothermal air stream at ΔT = 5oC, at 0,5 m/s velocity limit (1) Max. air flow stream [m3/h ] Nominal heat power...

 Open the catalog to page 7
AIR HEATING AND VENTILATION Fan heaters LEO-8

CONTROL SYSTEMS for LEO heaters LEO / LEO BMS CONTROLLER T-box basic version basic version the simplest regulation of 3-step fans. Fan heater operation is controlled by 3-step fan speed controller with thermostat. the advanced regulation of 3-step fans via HMI programmable controller. the intelligent regulation system of 3-step fans. Speed regulation of energy-efficient fan via T-box controller. Controller T-BOX Types of regulation/control Manual 3-step air flow regulation Automatic 3-step air flow regulation Modes Heating / Ventilation Operation in continuous or thermostatic mode Weekly programmer...

 Open the catalog to page 8
AIR HEATING AND VENTILATION Fan heaters LEO-9

WALL-MOUNTED TEMPERATURE SENSOR Wall mounted temperature sensor makes it possible to measure the temperature in a different zone than the controller. Possibility of temperature measurement The connection of wall mounted temperature sensor n/d to HMI controller to DRV control module Temperature sensor integrated NTC or integrated PT-1000 or integrated SRQ VALVES For control the heating medium flow, the two- or three-way valves with electric actuator can be applied. Compatibility of valves with LEO fan heaters CONNECTION DIAGRAMS CONTROLLER TS / HMI NTC It is possible to apply RX splitters to increase...

 Open the catalog to page 9
AIR HEATING AND VENTILATION Fan heaters LEO-10

CONFUSOR LEO Material: powder-painted steel, RAL 9007 Weight: Confusor LEO L: 3,8 kg Confusor LEO XL: 6,2 kg Confusor increases air flow speed. It results in faster air distribution to the lower zones of the room. Material: powder-painted steel, RAL 9007 Weight: Outlet grille LEO L: 2,8 kg Outlet grille LEO XL: 4,8 kg Outlet grille improves air distribution. It is perfect solution for low level ceiling rooms, where heaters are installed under the ceiling. W hen device is mounted under the ceiling please note the proper nonisothermal air stream range. MIXING CHAMBER LEO fan heaters with LEO KM...

 Open the catalog to page 10
AIR HEATING AND VENTILATION Fan heaters LEO-11

LEO + KM + UVO The easiest mechanical ventilation system. MIXING CHAMBER installation under the ceiling installation using pins installation using brackets Installation brackets Enable easy and aesthetic installation on the walls. W hen device is mounted under the ceiling please note the proper nonisothermal air stream range. RECOMMENDED INSTALLATION DISTANCE LEO S1 + KM S Fan heaters with LEO KM mixing chamber Nominal heat power (70/50/16 C, III step) [kW] o Max. acoustic pressure level [dB(A)](2) Max. acoustic power level [dB(A)] Max. heating water temperature [°C] Weight of unit filled with...