1. Catalogs
  2. Flowair
  3. AIR CURTAINS AND AIR CURTAIN-FAN HEATER UNITS

AIR CURTAINS AND AIR CURTAIN-FAN HEATER UNITS
1 /34Pages

AIR CURTAINS AND AIR CURTAIN-FAN HEATER UNITS

AIR CURTAINS AND AIR CURTAIN-FAN HEATER UNITS
1 /34Pages

Catalog excerpts

AIR CURTAINS AND AIR CURTAIN-FAN HEATER UNITS-1

AIR CURTAINS AND AIR CURTAIN-FAN HEATER UNITS Air curtains ELiS and Slim

 Open the catalog to page 1
AIR CURTAINS AND AIR CURTAIN-FAN HEATER UNITS-2

AIR CURTAINS AND AIR CURTAIN-FAN HEATER UNITS ELiS B COMPARE ELiS SOLUTIONS ELiS AX INCREASED AESTHETICS TECHNICAL DATA Slim Version Acoustic pressure level N – without heating elements W – water heat exchanger – speed limit at the floor level – outlet air velocity shops shopping centers petrol stations commercial buildings shopping centers/malls logistics centers hotels offices shopping centers ELiS and Slim • air curtains and air cur

 Open the catalog to page 2
AIR CURTAINS AND AIR CURTAIN-FAN HEATER UNITS-3

UNIVERSAL SOLUTIONS INDUSTRIAL BUILDINGS TECHNICAL DATA ELiS T Acoustic pressure level The sound pressure level measured in a room with an average sound absorption capacity, 1500 m3; directivity factor Q = 2 shopping centers restaurants train stations ELiS and Slim • air curtains and air curtain-fan heater units industrial halls logistics centers wareho

 Open the catalog to page 3
AIR CURTAINS AND AIR CURTAIN-FAN HEATER UNITS-4

FLOWAIR R&D LAB FLOWAIR - expert and manufacturer of HVAC equipment is a member of the EUROVENT Europe’s Industry Association for Indoor Climate. This organisation brings together the largest companies in the industry, which jointly create new guidelines and recommendations that are eventually presented to the European Commission. The Association is looking for solutions related to energy savings inside buildings and the use of air curtains is one of recommended solutions. The use of air curtains allows for thermal protection of the room. Curtains create an air barrier in the door opening and...

 Open the catalog to page 4
AIR CURTAINS AND AIR CURTAIN-FAN HEATER UNITS-5

TEST OF AIR CURTAIN EFFICIENCY IN RELATION TO TEMPERATURE DIFFERENCES The test was carried out in the FLOWAIR R&D lab, in order to measure the effectiveness of the air barrier created by the air curtain relative to the temperature difference. Measurement of air temperature difference between the „cooling” and „heating” chambers upon opening the door - with curtain in Off mode. Chamber 1 simulates external conditions (air temperature is 2°C), and chamber 2 simulates conditions inside the building (air temperature is 20°C). Simulation of external conditions - two closed chambers (cooling and heating)....

 Open the catalog to page 5
AIR CURTAINS AND AIR CURTAIN-FAN HEATER UNITS-6

NEW ELiS AX AIR CURTAIN Advantages of AX high efficiency quiet work heating power INSTALLATION 3 mounting possibilities The ELiS AX curtain can be mounted both vertically and horizontally using dedicated consoles or brackets. Additionally, the curtain is equipped with integrated fasteners, so it can be suspended with threaded M8 rods, solution often used when mounting next to glass walls. ELiS and Slim • air curtains and air curtain-fan heater units

 Open the catalog to page 6
AIR CURTAINS AND AIR CURTAIN-FAN HEATER UNITS-7

Optiflow technology ensures an energy efficient airflow through the aircurtain and guarantees high thermal comfort. How does it work? The air enters the curtain via 2 air intakes: the lower and the upper intake Then the air stream flows evenly throughout the entire area of the heat exchanger. Next the hot air stream passes through the fans and compression chamber and s directed towards two adjustable, dynamic outlet louvres which create 3 separate air streams, enuring an excellent air barrier and additional thermal comfort in the room. even temperature distribution throughout the entire area...

 Open the catalog to page 7
AIR CURTAINS AND AIR CURTAIN-FAN HEATER UNITS-8

AIR CURTAIN ELiS AX ELiS AX 36 Range(1) [m] White with black elements (1) (2) according to ISO 27327-1 Power and temperature range for parameters: min. efficiency, temperature of the heating medium 40/30oC, temperature of the air at the inlet to devices 18oC - max. efficiency, heating medium temperature 60/40oC, air temperature at the inlet to the device 18oC AVAILABLE TYPES OF UNITS: APPLICATION ELiS AX curtains can be used in various facilities such as commercial buildings (cafes, restaurants, museums, shopping malls), and industrial buildings (warehouses, logistic centers, manufacturing plants)...

 Open the catalog to page 8
AIR CURTAINS AND AIR CURTAIN-FAN HEATER UNITS-9

TECHNICAL DATA Air curtains ELiS AX Heating capacity(4) [kW] Max. water temperature [°C] Heating capacity(4) [kW] Max. water temperature [°C] According to ISO 27327-1 The sound pressure level measured in a room with an average sound absorption capacity, 1500 m3; direction factor Q = 2 (3) Sound power level according to ISO 27327-1 (4) Power and temperature range specified for parameters: min. efficiency, heating medium temperature 40/30oC, air temperature at the inlet to the device 18oC - max. efficiency, heating medium temperature 60/40oC, air temperature at the inlet to the device 18oC (1)...

 Open the catalog to page 9
AIR CURTAINS AND AIR CURTAIN-FAN HEATER UNITS-10

V – air flow PT – heating capacity Tp1 – inlet air temperature Tp2 – outlet air temperature Tw1 – nlet water temperature i Tw2 – utlet water temperature o Qw – water flow in the heat exchanger Δpw – water pressure drop in the heat exchanger ELiS and Slim • air curtains

 Open the catalog to page 10
AIR CURTAINS AND AIR CURTAIN-FAN HEATER UNITS-11

V – air flow PT – heating capacity Tp1 – inlet air temperature Tp2 – outlet air temperature Tw1 – nlet water temperature i Tw2 – utlet water temperature o Qw – water flow in the heat exchanger Δpw – water pressure drop in the heat exchanger HEAT POWER CALCULATOR Select a device for different parameters, scan QR code. ELiS and Slim • air curtains and

 Open the catalog to page 11
AIR CURTAINS AND AIR CURTAIN-FAN HEATER UNITS-12

White with black elements and deep black RAL according to ISO 27327-1 Slim W power and temperature range specified for the parameters: fan speed III, heating medium temperature 40/30°C air te perature at the inlet to the device 20°C - fan speed III, heating medium temperature 110/90°C, air temperature at the inlet to the device 0°C; Slim E performance at power range: from 1N 230/50 to 3N 400/50 (3) RAL 9003 and 9005. Any RAL color upon request (1) (2) SPECIAL PAINTING ON REQUEST AVAILABLE TYPES OF UNITS: APPLICATION The Slim curtain will work wherever doors are often opened, in shops, restaurants,...

 Open the catalog to page 12
AIR CURTAINS AND AIR CURTAIN-FAN HEATER UNITS-13

1 set of brackets - 3 mounting possibilities RODS In standard Slim air curtains have special mounting holes for installation with threaded rods. BRACKETS FOR Slim Invisible mounting system, for both vertical and horizontal mounting. DIMENSIONS The thinnest air curtain on the market CAD drawings and documentation for all available versions of ELiS visit www.flowair.com ELiS and Slim • air curtains and air curtain-fan heater units

 Open the catalog to page 13
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.