Catalog excerpts
Flexible Impeller Pumps 04 Introduction Introduction to Sanitary Pumps Epoxy / Phenolic Plastic Stainless Steel Sanitary Pumps Model Variants Stainless Steel Impeller Replacement Guide
Open the catalog to page 104 Flexible Impeller Pumps INTRODUCTION Flexible Impeller Product Range There are probably few parts of the world where the Xylem Jabsco family of products is not in use or where our brands are not known. The reason is simple: “Make good fit-for-purpose products and you will get a good name.” This catalog is designed to help you understand the basics of a flexible impeller pump (FIP) and supply you with a quick reference guide, enabling you to choose the correct pump for the application. JACK ART BRIGGS STREETER COMPANY • To come up with the name Jabsco, these inventors used the first...
Open the catalog to page 204 Flexible Impeller Pumps EPOXY / PHENOLIC PLASTIC 12310 Series Phenolic Plastic Flex Pump 12560 Series Phenolic Plastic Flex Pump Use where corrosion-resistant plastic material, self-priming, flow and debris tolerance are desired. Use neoprene for water and general-purpose pumping. A nitrile impeller is ideal for oil-based products. Use FKM for hydrocarbons and solvents. Motor is not explosion-proof. Do not run dry. SPECIFICATIONS FOR US MARKETS Use where corrosion-resistant plastic material, self-priming, flow and debris tolerance are desired. Use neoprene for water and general-purpose...
Open the catalog to page 304 Flexible Impeller Pumps EPOXY / PHENOLIC PLASTIC 12290 Series Phenolic Plastic Flex Pump 17430 Series Epoxy Utility Pump Use where corrosion-resistant phenolic or glass-filled epoxy material, self-priming and debris tolerance are desired. A nitrile impeller is ideal for oil-based products. Use neoprene for water and general-purpose pumping. Use FKM for hydrocarbons and solvents. Long-lasting AC induction motor has no brushes to wear out. Motor is not explosion-proof. Do not run dry. Use where corrosion-resistant phenolic or glass-filled epoxy material, self-priming and debris tolerance...
Open the catalog to page 404 Flexible Impeller Pumps EPOXY / PHENOLIC PLASTIC 28250 Series Pedestal Pump & 28260 Series Epoxy Head Kit Pump 28350 Series Pedestal Pump & 28360 Series Epoxy Head Kit Pump • Non-pulsating flow, proportional to speed • Non-pulsating flow, proportional to speed • Handles hard or soft solids – 0.2" (5mm) maximum diameter • No metal parts in liquid contact • Handles hard or soft solids – 0.2” (5mm) maximum diameter • Minimal shear to thixotropic fluids • High-chemical-resistance epoxy plastic • Fits IEC standard motor B3/B14, frame 80 (model 28260) • Fits IEC standard motor B3/B14, frame 80...
Open the catalog to page 504 Flexible Impeller Pumps EPOXY / PHENOLIC PLASTIC 30510 Series Epoxy Plastic Pedestal & Close-Coupled Flex Pump 30520 Series Epoxy Plastic Pedestal & Close-Coupled Flex Pump Use where single or variable speed operation and plastic-epoxy material is desirable. Self-priming, 8 GPM (30 LPM) flow and debris-tolerant. A nitrile impeller is ideal for oil-based products. Use neoprene for water and generalpurpose pumping. Use FKM for hydrocarbons and most solvents. Optional EPDM standard and high-pressure impeller kits (7614-0002) and (8980-0002) for hygienic applications and some keytone...
Open the catalog to page 604 Flexible Impeller Pumps BRONZE 17830 Reversible DC Water Puppy 18670 Commercial Duty DC Water Puppy FOR INTERNATIONAL MARKETS The Commercial Duty Water Puppy has 25 percent more flow than the standard model and a heavy-duty PMDC motor. For general transfer pumping where self-priming, 8 GPM (30.4 LPM) flow and debris tolerance are required. Oil-resistant nitrile impeller is standard. Do not run dry. Especially suited for viscous fluids and engine oil transfer where self-priming and 3 GPM (11.4 LPM) flow is required. Pump oil from crankcase to storage container, and from storage container...
Open the catalog to page 704 Flexible Impeller Pumps BRONZE 23920 Extended Run Dry Utility Puppy 2000/3000 Continuously rated, medium-duty pumps for general-purpose use. Continuously rated, heavy-duty pumps for general-purpose use. FEATURES • Simple design means fewer wearing parts LIQUID TEMPERATURE RANGE Stainless steel Model 2000 – lip seal, nitrile Model 3000 – mechanical seal, carbon, ceramic, nitrile 23620 Mini Puppy Continuously rated, medium-duty pumps for general-purpose use. Model 2000 – 4.3" high x 7" long x 4.9" wide (110mm x 121mm x 124mm) Model 3000 – 4.3" high x 8.5" long x 4.9" wide (110mm x 179mm x...
Open the catalog to page 804 Flexible Impeller Pumps BRONZE 18610 Bronze Utility Pump 11810 Bronze AC Utility Pump For general transfer pumping where self-priming, 6 GPM (22.8 LPM) flow, debris tolerance and portable 115V AC operation is desired. Choice of impeller materials. Use nitrile for oil-based products. Use FKM for hydrocarbons and solvents. Use neoprene for water and general-purpose pumping. Long-lasting AC induction motor has no brushes to wear out. Do not pump gasoline or other flammable liquids. Do not run dry. Motor is not explosion-proof. For continuous operation at 75˚F (24°C), do not exceed 15 psi (1...
Open the catalog to page 904 Flexible Impeller Pumps BRONZE 6050 Bronze AC Utility Pump For general transfer pumping using 115V AC power where self-priming, 23 GPM (87 LPM) flow and debris tolerance are required. Oil-resistant nitrile impeller is standard. Do not run dry. • Will handle viscosities up to 500 cP • Uses standard IEC motor • Will handle hard or soft solids 60Hz – 115V and 230V AC, single phase, non-CE • Will tolerate abrasive wear • Non-pulsating flow 3/4 HP TEFC or ODP AC induction type MOTOR 3/8" BSP internal thread and 3/4" (19mm) bore hose connections 8' (2.4m) power cord with 3-prong grounded plug...
Open the catalog to page 1004 Flexible Impeller Pumps BRONZE • Uses standard IEC motor • Dry-running capability for 30 minutes without damage to pump (post operation) • Dry-running capability for 30 minutes without damage to pump (post operation) • Handles hard or soft solids • Handles hard or soft solids • Tolerates abrasive wear • Tolerates abrasive wear • Non-pulsating flow • Non-pulsating flow • Uses standard IEC motor Sanitary neoprene Bronze with integral fluid reservoir to protect pump against dry running for up to 30 minutes (post operation) PUMP HEAD Bronze with integral fluid reservoir to protect pump...
Open the catalog to page 11All FLOJET catalogs and technical brochures
-
HPR10/15
2 Pages
-
GP50/25
2 Pages
-
GP28/11
2 Pages
-
GP20/12
2 Pages
-
VFLO 5.0
2 Pages
-
Searchlights
8 Pages
-
Ventilation Blowers
4 Pages
-
General Purpose Pumps
8 Pages
-
Oil Change & Diesel
6 Pages
-
Washdown Pumps
2 Pages
-
Water Pressure Systems
10 Pages
-
Toilet Systems
14 Pages
-
Livewell/Baitwell Pumps
6 Pages
-
Bilge Pumping Systems
24 Pages
-
Speciality Products
6 Pages
-
Sliding Vane Pumps
2 Pages
-
Oscillating Lobe Pumps
2 Pages
-
Lobe Pumps
3 Pages
-
Hand Pumps
2 Pages
-
Diaphragm Pumps
16 Pages
-
Centrifugal Pumps
17 Pages
-
INTERNATIONAL Beverage
15 Pages
-
4100 series
2 Pages
-
C Series
4 Pages
-
5000 Series
2 Pages
-
U Series
2 Pages
-
M502052
2 Pages
-
International Industrial Pumps
100 Pages
-
PS Series
2 Pages
-
SPC42
2 Pages
-
GP20/22
2 Pages
-
GP20/18
2 Pages
-
V100, 060 & 040 V-Jet
5 Pages
-
Bottled Water System Plus
2 Pages
-
LF Plus Series
2 Pages
-
V125 V-Jet
2 Pages
-
Flojet Beverage Catalogue
43 Pages
-
FLOJET BevJet Brochure
12 Pages
Archived catalogs
-
F100-218F
51 Pages
-
pt6_7_8Gear_Hand_LobePumps
8 Pages
-
pt5B_FlexibleImpellers
26 Pages
-
pt5A_FlexibleImpellers
15 Pages
-
Diaphragm_DrumPumps
29 Pages
-
Centrifugal Pumps
37 Pages
-
pt1Cover
11 Pages
-
Flojet Industrial Catalogue
24 Pages