Technical Specification FLUXUS® F601 Portable Ultrasonic Flow Measurement of Liquids Portable instrument for non-invasive, quick ultrasonic flow measurement with clamp-on technology for all types of piping Features • Precise bi-directional and highly dynamic flow measurement with the non-intrusive clamp-on technology • High precision at fast and slow flow rates, high temperature and zero point stability • Portable, easy-to-use flow transmitter with 2 flow channels, multiple inputs/outputs, an integrated data logger with a serial interface • Water and dust-tight (NEMA 4); resistant against oil, many liquids and dirt • Li-Ion battery provides up to 14 hours of measurement operation • Automatic loading of calibration data and transducer detection for a fast and easy set-up (less than 5 min), providing precise and long-term stable results • User-friendly design • Transducers available for a wide range of inner pipe diameters ( 0.25...256 in) and fluid temperatures ( -40...+752 °F) • Probe for wall thickness measurement available • Robust, water-tight (NEMA 6) transport case with comprehensive accessories • HybridTrek automatically switches between transit time and NoiseTrek mode of measurement when high particulate flows are encountered • QuickFix for fast mounting of the flow transmitter in difficult conditions FLUXUS F601 supported by handle Measurement with transducers mounted by mounting frames and flow transmitter fixed to the pipe by the QuickFix pipe mounting fixture Applications Designed for the following industries: • Chemical industry • Water and wastewater industry • Oil and gas industry • Cooling systems and air conditioners • Facility management • Aviation industry Measurement equipment in transport case TSFLUXUS_F601V1-5US_Lus, 2012-01-09

Open the catalog to page 1
Technical specification FLUXUS F601 - 2

Technical Specification

Open the catalog to page 2
Technical specification FLUXUS F601 - 3

Technical Specification Function Measurement Principle Transit Time Difference Principle In order to measure the flow of a medium in a pipe, ultrasonic signals are used, employing the transit time difference principle. Ultrasonic signals are emitted by a transducer installed on the pipe and received by a second transducer. These signals are emitted alternately in the flow direction and against it. As the medium in which the signals propagate is flowing, the transit time of the ultrasonic signals in the flow direction is shorter than against the flow direction. The transit time difference,...

Open the catalog to page 3
Technical specification FLUXUS F601 - 4

Technical Specification Number of Sound Paths The number of sound paths is the number of transits of the ultrasonic signal through the medium in the pipe. Depending on the number of sound paths, the following methods of installation exist: • reflect mode The number of sound paths is even. Both of the transducers are mounted on the same side of the pipe. Correct positioning of the transducers is easier. • diagonal mode The number of sound paths is odd. Both of the transducers are mounted on opposite sides of the pipe. • direct mode Diagonal mode with 1 sound path. This should be used in the...

Open the catalog to page 4
Technical specification FLUXUS F601 - 5

Technical Specification Typical Measurement Setup power supply unit/battery charging unit RS232 transducers analog/binary outputs analog inputs Example of a measurement setup in reflect mode return line supply line volumetric flow rate temperature probe supply temperature temperature probe return temperature Example of a heat flow measurement

Open the catalog to page 5
Technical specification FLUXUS F601 - 6

Technical Specification Flow Transmitter Technical Data FLUXUS design measurement measurement principle flow velocity repeatability medium temperature compensation accuracy1 with standard calibration with extended calibration (optional) with field calibration2 flow transmitter power supply battery power consumption number of flow measuring channels signal attenuation measuring cycle (1 channel) response time housing material degree of protection dimensions weight fixation operating temperature display menu language measuring functions physical quantities totalizer calculation functions...

Open the catalog to page 6
Technical specification FLUXUS F601 - 7

Technical Specification FLUXUS communication interface serial data kit software (all Windows™ versions) сable adapter transport case dimensions outputs number accessories range accuracy active output passive output range open collector F601 RS232/USB - FluxData: download of measurement data, graphical presentation, conversion to other formats (e.g. for Excel™) - FluxKoef: creating medium data sets RS232 RS232 - USB 19.7 x 15.7 x 7.5 in The outputs are galvanically isolated from the transmitter. see standard scope of supply on page 9, max. on request output adapter (if number of outputs > 4)...

Open the catalog to page 7
Technical specification FLUXUS F601 - 8

Technical Specification

Open the catalog to page 8
Technical specification FLUXUS F601 - 9

Technical Specification Standard Scope of Supply F601 Standard F601 Energy F601 Double Energy F601 Multifunctional flow measurement on liquids 2 independent measuring channels temperature-compensated calculation of mass flow rate integrated heat flow computer for monitoring of energy flows simultaneous monitoring of simultaneous monitoring of flow measurement taking into account other process energy flow and flow, 2 energy flows, e.g. heating systems e.g. heating systems, heat quantities, e.g. density, viscosity exchangers) outputs passive current output binary output inputs temperature...

Open the catalog to page 9
Technical specification FLUXUS F601 - 10

Technical Specification input adapter output adapter adapter for voltage and current inputs transducers measuring channel A transducers measuring channel B C H power supply unit/battery charging unit

Open the catalog to page 10
Technical specification FLUXUS F601 - 11

Technical Specification Example for the Equipment of a Transport Case serial data kit user manual, Quick Start Guide measuring tape power supply unit, mains cable transducer mounting fixture wall thickness probe (optional) coupling compound QuickFix pipe mounting fixture temperature probes (optional)

Open the catalog to page 11
Technical specification FLUXUS F601 - 12

Technical Specification transducer order code inner pipe diameter [in]

Open the catalog to page 12
Technical specification FLUXUS F601 - 13

Technical Specification Transducer Order Code 7, 8 extension cable description connection system operating temperature transducer frequency set of ultrasonic flow transducers for liquids measurement, shear wave K normal temperature range extended temperature range (shear wave transducers with transducer frequency M, Q) NN with Lemo connector XXX cable length in m, for max. length of extension cable see page 22 LC long transducer cable (only FSK) shear wave transducer 1 MHz, normal temperature range, connection system NL with Lemo connector /

Open the catalog to page 13

All FLEXIM Flexible Industriemesstechnik GmbH catalogs and technical brochures

  1. PIOX ID

    4 Pages

  2. Busil

    4 Pages

  3. FLEXIM

    2 Pages

  4. FLUXUS Cryo

    2 Pages

  5. FLUXUS CA

    4 Pages

  6. FLUXUS F401

    2 Pages

  7. FLUXUS SIL

    4 Pages

  8. FLUXUS XLF

    2 Pages

  9. FLUXUS G70x

    52 Pages

  10. FLUXUS G601

    29 Pages

  11. FLUXUS G80x

    33 Pages

Archived catalogs