Catalog excerpts
FLEXIM More than 25 years of experience in non-invasive ultrasonic flow measurement Permanent ultrasonic flow meter FLEXIM Austria GmbH Phone: +43 33 26 529 81 office@flexim.at Non-invasive Water Flow and Temperature Monitoring FLEXIM Instruments Benelux B.V. Phone: +31 10 24 92 333 benelux@flexim.com Technical Specifications Volumetric flow rate uncertainty Volumetric flow rate repeatability Temperature reading uncertainty Number of measuring channels Power supply Transducer degree of protection Transducer for pipe sizes range Transducer for temperature range 4 - 20 mA active / passive 4 - 20 mA HART active / passive pulse / binary Digital communication Modbus RTU/TCP BACnet MSTP/IP M-Bus Profibus PA Foundation Fieldbus For more detailed Information please download the Technical Specifications here: www.fl exim.com. FLEXIM France SAS Phone: +33 4 27 46 52 10 info@flexim.fr FLEXIM Instruments UK Ltd. Phone: +44 1606 781 420 sales@flexim.co.uk Temperature measurement accuracy of ±0.2 K _______ FLEXIM Middle East Phone: +971 4430 5114 salesme@flexim.com Minimal installation costs and zero pipe interference _______ Leakage Alarm Outstanding low flow accuracy down to 0.01 m/s _______ Permanently drift-free and no zero calibration needed _______ FLEXIM India Phone: +91 98114 49285 salesindia@flexim.com Temperature compensated transducers _______ FLEXIM Instruments Asia Pte Ltd. Phone: +65 67 94 53 25 salessg@flexim.com FLEXIM Instruments China Phone: +86 21 64 95 75 20 shanghai@flexim.com FLEXIM S.A, Chile Phone: +56 22 32 03 62 80 info@flexim.cl FLEXIM Service and Support Center South America, Argentina Phone: +54 11 49 20 71 00 flexim@escoarg.com.ar www.escoarg.com.ar FLEXIM AMERICAS Corporation, USA Phone: +1 63 14 92 23 00 salesus@flexim.com BUWDV3-1EN 09/2019 Subject to change without notification! Permanent maintenance-free coupling pads _______ Transducers can be buried (no chamber required) when measuring matters
Open the catalog to page 1Drift-free flow measurement There is no method of zero drift correction for our instruments – because they just don’t drift. This also applies to the WD Series that is installed without zero calibration and remains drift-free, permanently. FLEXIM is the only company that accomplishes this, thanks to its unique combination of matched piezo-transducers and advanced factory calibration. When creating a new flow measurement point the main costs are not incurred by the instrument but by the installation work (supply interruption, pipe cutting, pipe flushing, etc.). These costs are significantly...
Open the catalog to page 2Drift-free flow measurement There is no method of zero drift correction for our instruments – because they just don’t drift. This also applies to the WD Series that is installed without zero calibration and remains drift-free, permanently. FLEXIM is the only company that accomplishes this, thanks to its unique combination of matched piezo-transducers and advanced factory calibration. When creating a new flow measurement point the main costs are not incurred by the instrument but by the installation work (supply interruption, pipe cutting, pipe flushing, etc.). These costs are significantly...
Open the catalog to page 3FLEXIM More than 25 years of experience in non-invasive ultrasonic flow measurement Permanent ultrasonic flow meter FLEXIM Austria GmbH Phone: +43 33 26 529 81 office@flexim.at Non-invasive Water Flow and Temperature Monitoring FLEXIM Instruments Benelux B.V. Phone: +31 10 24 92 333 benelux@flexim.com Technical Specifications Volumetric flow rate uncertainty Volumetric flow rate repeatability Temperature reading uncertainty Number of measuring channels Power supply Transducer degree of protection Transducer for pipe sizes range Transducer for temperature range 4 - 20 mA active / passive 4 -...
Open the catalog to page 4All FLEXIM Flexible Industriemesstechnik GmbH catalogs and technical brochures
-
PIOX ID
4 Pages
-
Busil
4 Pages
-
FLEXIM
2 Pages
-
Energy Efficiency
6 Pages
-
FLUXUS Cryo
2 Pages
-
Chemical Industry Solutions
8 Pages
-
FLUXUS CA
4 Pages
-
FLUXUS F401
2 Pages
-
Product Catalogue
24 Pages
-
FLUXUS SIL
4 Pages
-
FLUXUS XLF
2 Pages
-
Upstream Solutions
8 Pages
-
FLUXUS G70x
52 Pages
-
FLUXUS G601
29 Pages
-
FLUXUS G80x
33 Pages
-
Ultrasonic Flowmeters for Gases
12 Pages
-
Process Refactometer PIOX R
8 Pages
-
Portable ultrasonic flowmeter
12 Pages