Fixturlaser NXA Ultimate - 2

Since the very beginning in 1984, ELOS Fixturlaser has helped indu- The Name Says it All With the Fixturlaser NXA Ultimate you have covered any kind of angle that needs to be covered of your machinery. It includes shaft alignment applications as well as geometric applications, hence, as the name says, it is an ultimate measurement tool. stries throughout the world to achieve more profitable and sustainable production. We have reached where we are today by having the courage to think beyond the norm and follow slightly unconventional paths. We have had the courage to make mistakes and find...

Open the catalog to page 2
Fixturlaser NXA Ultimate - 3

Adaptive User Interface Fixturlaser NXA Ultimate will guide you throughout the measurement, step by step. Shaft Alignment Enter Dimensions Correcting Vertically Correcting Horizontally Evaluate Results Rectangular Flatness

Open the catalog to page 3
Fixturlaser NXA Ultimate - 4

Shaft Alignment The Fixturlaser NXA Ultimate comes with technology enabling functions and capabilities, which in many cases are industry firsts, for example: • CCD detectors with ultra high definition resolution. • New sensor units with Bluetooth incorporated are the industry’s most compact, yet, they feature a 30 mm detector surface and line lasers. • The OmniView feature keeps track of the position of both the user and the machine to show the screen display from the user’s perspective, thanks to the built-in gyroscope (6-axis MEMS Inertial Motion Sensor) in the display unit. • Ability to...

Open the catalog to page 4
Fixturlaser NXA Ultimate - 5

Geometric Measurements Fixturlaser’s laser based geometry system is characterized by its user friendliness and versatility, such as: • Flatness measurements on foundations and machine beds to obtain optimal prerequisites for machine installations. Measurements can be done on foundation with both rectangular and circular configurations. • Straightness measurements on machine beds, guideways, or support structures, are also available with the Fixturlaser NXA Ultimate. • The graphic user interface is intuitive and 3D animated, with icons and color coded symbols to guide you throughout the...

Open the catalog to page 5
Fixturlaser NXA Ultimate - 6

Features Fixturlaser NXA Ultimate OmniView With the OmniView function, the screen display changes in real time always showing the machine being aligned from the viewing angle as seen by the operator, i.e. the system logs the user’s position and keeps track of it in relation to the machine. No other laser alignment system on the market has this unique feature. VertiZontal Moves If the machine is misaligned, the Fixturlaser NXA Ultimate calculates how much you need to remove or add shims in order to correct the machine vertically. When moving on to horizontal correction, the system goes live...

Open the catalog to page 6
Fixturlaser NXA Ultimate - 7

Horizontal Shaft Alignment Determine and correct the relative position of two horizontally mounted machines that are connected, such as a motor and a pump, so that the rotational centers of the shafts are collinear. Vertical Shaft Alignment Determine and correct the relative position of two vertically/flange mounted machines that are connected, such as a motor and a pump, so that the rotational centers of the shafts are collinear. Machine Train™ Alignment Align a set-up of more than two rotating machines that are connected to each other. Softcheck™ Softcheck™ checks if there is a soft foot...

Open the catalog to page 7
Fixturlaser NXA Ultimate - 8

Fixturlaser NXA Ultimate System Weight including all standard parts: Housing Material: Anodized aluminium Operating Temp: Display Unit Storage Temp: Laser class: IP 65 (Dust tight and protected against water jets) Measuring distance: Laser sweep flatness: Angular prism accuracy: Environmental protection: Display size: Operating time Battery charging time (system off, room temperature): 6-Axis MEMS Inertial Motion Sensor with drift compensation and automatic field calibration. 10 hours continuous use (with 50% LCD backlight) 5 hours (1 hour charge – 6 hours operating time) Power supply:...