Group: Fives Group
Catalog excerpts
Pillard Windcross™ Ultrasonic anemometer for Road and Railway tunnels Wind velocity measurement unit ensuring optimized ventilation and safety • ccurate measurement along large path and flow A velocity • Remote access with digital communication • Alignment laser integrated for easy installation • No calibration required on site • Typical interval maintenance > 1 year • Stainless steel durable conception
Open the catalog to page 1ULTIMATE TECHNOLOGY WITH A LIMITED INVESTMENT Pillard Windcross™ propose Ultrasonic technology to measure wind velocity and direction. The Ultrasonic technology is based on sound propagation through the air; two transducers are alternately transmitters and receivers. The outward and return transit times induced by the air flow are measured. Using the time difference, the internal calculator measures the wind speed and direction compared to its reference axis. The measured value allows automatic activation of ventilation when required. Power supply Power consumption Operating temperature...
Open the catalog to page 2All FIVES PILLARD catalogs and technical brochures
-
Pillard Nocostop Eco
2 Pages
-
Pillard Nocostop Premium™
2 Pages
-
Pillard Opastop® GP4000T-EX
2 Pages
-
Pillard Opastop® GP4000H-EX
2 Pages
-
Pillard Dieselight™
2 Pages
-
Pillard Opastop® GP4000H
2 Pages
-
OPAGAZ
2 Pages
-
Pillard Opastop® GP4000H-C
2 Pages
-
Pillard DarkscanFlex™
2 Pages
-
Pillard Oxycheck™
2 Pages
-
Pillard Packlight™
2 Pages
-
Pillard flame scanners
4 Pages
-
Pillard Smokecheck™
2 Pages
-
Pillard Powerpack™
2 Pages
-
Pillard Windcheck™
2 Pages
-
Pillard Opastop® GP4000H
2 Pages
-
Pillard TK DRAIN
2 Pages
-
Pillard Opastop® GP4000T-EX
2 Pages
-
Pillard TK Drain
2 Pages
-
INDUCTFLAM® L
2 Pages
-
OPASTOP GP4000H-EX
2 Pages
-
OPAGAZ
2 Pages
-
Pillard RotaFlam®
2 Pages
-
Pillard PrecaFlam™
2 Pages
-
Pillard NovaFlam®
2 Pages
-
Pillard Powerpack™
2 Pages
-
Blower Silencers
2 Pages
-
Series 2300 Turbo Blowers
7 Pages
-
SAF – Adjustable Flow Valve
2 Pages
-
Limiting Orifi ce Gas Valves
3 Pages
-
Double Shutoff Valve
2 Pages
-
Oil Shutoff Valves
6 Pages
-
Pneumatic Cycle Valve
2 Pages
-
Air Cycling Valve
2 Pages
-
Wafer Butterfly Valves
4 Pages
-
1008A-C / 1010A-C-1
3 Pages
-
Adjustable Port Valves
4 Pages
-
Butterfl y Valves
4 Pages
-
ITAS Ductflame
4 Pages
-
ITAS Speedflame
4 Pages
-
ITAS Dryflame
4 Pages
-
ITAS Intensityflame
4 Pages
-
Adjustable Port Valves
2 Pages
-
Pillard Opastop® GP4000H
2 Pages
-
Waste heat recovery
48 Pages
-
Pillard Opastop® GP3050ST
2 Pages
-
Pillard SmokecheckTM
2 Pages
-
Pillard Windcheck™
2 Pages
-
Pillard NocostopTM
2 Pages
Archived catalogs
-
Pillard Packlight
2 Pages
-
Pillard flame scanners
4 Pages