Overview: The Pillard LM3086 SE is a dust and opacity monitor designed for industrial stacks, offering a simplified dust measurement system. It utilizes reliable and robust laser technology, ensuring easy installation and low maintenance. The system is equipped with a zero and span calibration system and provides continuous control of optical devices. It is MCERTS QAL1 approved, making it a dependable solution for continuous dust emission measurement and control across various industries.
Key Features:
  • Laser Light Source: The device features a laser light source with a measuring path up to 20 meters, excellent beam collimation, and a standard wavelength for long-term accuracy and stability.
  • Automatic Calibration: The system performs automatic calibration and zero checks 40 times per second, eliminating the optics dirt effect from measurement values.
  • Options: Includes an air sweeping device and compliance testing with U.S. EPA standards. It comes with a 3-year warranty.
Certifications:
  • MCERTS QAL1 certification according to EN 15267 and EN 14181 standards.
  • U.S. EPA 40 CFR Appendix B, PS1 (rev) performance.
  • IP66 protection rating and compliance with European electromagnetic compatibility regulations (2014/30/UE).
Technical Specifications:
  • Housing: 19’’ 3U aluminium rack.
  • Power Supply: 100 to 230 VAC, 50 Hz / 60 Hz / 15 VA.
  • Operating Temperature: 0 to +65 °C.
  • Measuring Range: 0 to 100% & 0 to 10,000 mg/m3, adjustable minimum 20 mg/Nm3.
  • Display: Dual line 16 characters alphanumeric LCD.
  • Outputs: Two 4-20 mA for 750 Ohms and one RS232.
  • Operational Modes: Diagnostic, auto zero & calibration, setup, main monitoring, manual, service/audit.
  • Alarm and Indicators: 7 relays with dry contact and indicator LEDs for various alerts.
Receiver & Transmitter Units:
  • Shell: Stainless steel 304.
  • Ambient Temperature: -30 °C to +65 °C.
  • Power Supply: 115 or 230 VAC, 40 VA.
  • Maximum Flue Gas Overpressure/Temperature: 25 mbar / +650 °C.
  • Path Length: 0 to 20 m.
Service: Includes commissioning assistance and maintenance contracts.
Conclusion: The Pillard LM3086 SE offers proven technology and accurate results through its transiometry principle, providing reliable measurements insensitive to ambient light.
See more

Catalog excerpts

Pillard LM3086 SE-1

Pillard LM3086 SE Dust & opacity monitor for industrial stacks Simplified dust measurement system •R eliable, robust laser technology • Easy installation and low maintenance • Zero and span calibration system •C ontinuous control of the optical devices • MCERTS QAL1 a

 Open the catalog to page 1
Pillard LM3086 SE-2

Pillard LM3086 SE is Fives’ reliable solution for opacity measurement to ensure continuous measure and control dust emissions to all stacks industries The Pillard LM3086 SE model is a certified equipment, approved by MCERTS. This device is able to measure and correct the contamination on optics thanks to the selfchecking function and correction of contamination. Through the transiometry principle, the laser light offers an accurate measurement insensitive to the ambient light. The measurement is very reliable thanks to a laser source, with a measuring path up to 20 meters. TECHNICAL FEATURES...

 Open the catalog to page 2

All FIVES PILLARD catalogs and technical brochures

  1. OPAGAZ

    2  Pages

  2. ITAS Dryflame

    4  Pages

Archived catalogs

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.