Group: Fives Group
Catalog excerpts
ITAS Ductflame Modular duct burners: F/L/R model for high temperature applications Plug and play solutions to reduce commissioning time Features • Applications: ovens, dryers, and fume incinerators • From 100kW to 30 MW • TAS Ductflame may be combined with other equipment in order to adapt to installation I structure and to supply variable pow
Open the catalog to page 1Air and fuel gas mixing is controlled in order to optimize both emission and efficiency; moreover, mixing takes place on nozzle outlets, thus avoiding any back firing. ITAS DUCTFLAME: MODEL F TYPES OF APPLICATIONS — Designed for applications requiring the production of large warm and clean air masses — All installations, where process air (such as fumes from gas turbine) may be used as combustion air, for example, atomizing burners for ceramics and steam-producing heaters — Each burner will be designed according to the process condition, depending on special application Other gas types upon...
Open the catalog to page 2ITAS DUCTFLAME: MODEL L TYPES OF APPLICATIONS — All installations, where the objective is to obtain air recovery, by introducing a minimum of fresh air quantity, like air recovery from oven — Each burner will be designed according to the process condition, depending on special application OPERATING CONDITIONS Other gas types upon request Higher turndown ratio can be reached with a burner staging.
Open the catalog to page 3ITAS DUCTFLAME: MODEL R TYPES OF APPLICATIONS — All processes, where combustion air quantity shall be as low as possible and controllable like high efficiency hoods in paper industry market — Each burner will be designed according to the process condition, depending on special application OPERATING CONDITIONS 750 °C Nominal capacity Turn each module (kw) down Differential pressure natural gas at burner inlet (mbar) Differential combustion air pressure (mbar) Higher turndown ratio can be reached with a burner staging. ultimate machines ultimate factory CONTACT US Fives ITAS S.p.A. Via...
Open the catalog to page 4All FIVES PILLARD catalogs and technical brochures
-
Pillard Windcross™
2 Pages
-
Pillard Nocostop Eco
2 Pages
-
Pillard Nocostop Premium™
2 Pages
-
Pillard Opastop® GP4000T-EX
2 Pages
-
Pillard Opastop® GP4000H-EX
2 Pages
-
Pillard Dieselight™
2 Pages
-
Pillard Opastop® GP4000H
2 Pages
-
OPAGAZ
2 Pages
-
Pillard Opastop® GP4000H-C
2 Pages
-
Pillard DarkscanFlex™
2 Pages
-
Pillard Oxycheck™
2 Pages
-
Pillard Packlight™
2 Pages
-
Pillard flame scanners
4 Pages
-
Pillard Smokecheck™
2 Pages
-
Pillard Powerpack™
2 Pages
-
Pillard Windcheck™
2 Pages
-
Pillard Opastop® GP4000H
2 Pages
-
Pillard TK DRAIN
2 Pages
-
Pillard Opastop® GP4000T-EX
2 Pages
-
Pillard TK Drain
2 Pages
-
INDUCTFLAM® L
2 Pages
-
OPASTOP GP4000H-EX
2 Pages
-
OPAGAZ
2 Pages
-
Pillard RotaFlam®
2 Pages
-
Pillard PrecaFlam™
2 Pages
-
Pillard NovaFlam®
2 Pages
-
Pillard Powerpack™
2 Pages
-
Blower Silencers
2 Pages
-
Series 2300 Turbo Blowers
7 Pages
-
SAF – Adjustable Flow Valve
2 Pages
-
Limiting Orifi ce Gas Valves
3 Pages
-
Double Shutoff Valve
2 Pages
-
Oil Shutoff Valves
6 Pages
-
Pneumatic Cycle Valve
2 Pages
-
Air Cycling Valve
2 Pages
-
Wafer Butterfly Valves
4 Pages
-
1008A-C / 1010A-C-1
3 Pages
-
Adjustable Port Valves
4 Pages
-
Butterfl y Valves
4 Pages
-
ITAS Speedflame
4 Pages
-
ITAS Dryflame
4 Pages
-
ITAS Intensityflame
4 Pages
-
Adjustable Port Valves
2 Pages
-
Pillard Opastop® GP4000H
2 Pages
-
Waste heat recovery
48 Pages
-
Pillard Opastop® GP3050ST
2 Pages
-
Pillard SmokecheckTM
2 Pages
-
Pillard Windcheck™
2 Pages
-
Pillard NocostopTM
2 Pages
Archived catalogs
-
Pillard Packlight
2 Pages
-
Pillard flame scanners
4 Pages