FITT Agix - HRV Components
76Pages

{{requestButtons}}

Catalog excerpts

FITT Agix - HRV Components - 1

fitt agix® Designing wellness Heat Recovery Ventilation system components Certified system The first EN 17192 system FITT VENTILATION SOLUTIONS

Open the catalog to page 1
FITT Agix - HRV Components - 3

Heat Recovery Ventilation system components

Open the catalog to page 3
FITT Agix - HRV Components - 4

fitt ventilation solutions 1.0 FITT VENTILATION SOLUTIONS The HRV system with superior performance FITT AGIX® : The Kiwa Quality (KQ) certified system according to EN 17192 FITT Agix dry: Centralised HRV with heat recovery and dehumidification FITT Agix cross: Centralised HRV with heat recovery FITT Agix® one: Decentralised HRV Antibacterial protection

Open the catalog to page 4
FITT Agix - HRV Components - 5

information and technical data 4.0 INFORMATION AND TECHNICAL DATA Dedicated accessories for FITT Agix dry ventilation units 4.3 DIFFUSION BOXES, GRIDS AND FILTERS 4.4 CENTRAL UNIT LINE Rectangular diffusion grids Linear diffusion boxes and grids Valves and grids for circular diffusers Central unit line Hose and insulated hose Hose accessories Technical documentation always accessible FITT AGIX

Open the catalog to page 5
FITT Agix - HRV Components - 6

The EN 17192 European standard is the first standard dedicated to non-metallic ventilation pipelines in residential buildings. It fully revisits the approach to the HRV system. Thanks to the Sanitized® antibacterial and antistatic treatments, FITT Agix® ensures high indoor air quality and optimises the efficiency of the ventilation system even in the long term.

Open the catalog to page 6
FITT Agix - HRV Components - 8

the HRV system with superior performance Since the signing of the Kyoto Protocol, the focus on energy efficiency and sustainability of buildings has become more stringent. Within the EU, it has led to the enactment of a series of regulations (currently being implemented in the various states) aimed at promoting better energy performance of buildings. According to these directives, all new buildings from 2016 will have to meet the requirements of class A, and those from 2021 of class A+, making the installation of HRV systems mandatory. In response to this need, FITT has developed FITT...

Open the catalog to page 8
FITT Agix - HRV Components - 9

fitt agix®: The Kiwa Quality (KQ) certified system according to EN 17192 Indoor air quality is fundamental to people's health and well-being: in developed countries, people spend 90% of their time indoors. Indoor air can be more polluted than outdoor air, because chemical indoor pollutants and biological man-made contaminants are added to the outdoor pollutants that are trapped and accumulated. • absence of hazardous substances, which This is why FITT, an international group pioneering the development of innovative technologies and solutions for the flow of fluids for domestic, professional...

Open the catalog to page 9
FITT Agix - HRV Components - 10

SYSTEM SIZING STANDARDS STANDARDS RELATING TO COMPONENTS UNI EN 10339:1995 - It provides a classification of the systems, the definition of the minimum requirements and the values of the reference quantities during operation. It applies to air conditioning systems intended for the well-being of people in enclosed buildings. UNI EN 13142:2013 - It specifies the performance characteristics of the components/products that may be required for the design and sizing of residential ventilation systems, in order to ensure pre-calculated comfort conditions relating to temperature, air speed,...

Open the catalog to page 10
FITT Agix - HRV Components - 11

Antibacterial protection FOR BETTER INDOOR AIR QUALITY FITT Agix® offers an innovative duct capable of ensuring a healthy environment. Its realisation is the result of a partnership between FITT and SANITIZED AG, the world's leading manufacturer of the hygienic antimicrobial function, which when integrated in the composition of the product inhibits the long-term growth of legionella, bacteria and mould. Indoor environments can be at least twice as polluted as the outdoors, with a significant impact on the well-being and quality of life of those who spend time and live in them. FITT Agix®...

Open the catalog to page 11
FITT Agix - HRV Components - 12

FITT Agix® cross offers even more powerful ventilation units with flow rates of up to 750 m3/h. The wide range allows for installation in larger residential units and even commercial dwellings. The introduction of the FITT Agix® dry dehumidification unit allows the management of two complementary systems using the same machine, with a maximum recovery capacity of 600 m3/h. The FITT Agix® one range includes 50 m3/h individual room recovery units, ideal when the installation of the whole centralised system is not feasible.

Open the catalog to page 12
FITT Agix - HRV Components - 14

fitt agix® dry: Centralised HRV with heat recovery and dehumidification GRAPHICS Bedroom wall supply with grid Study wall supply with grid Bathroom ceiling return with valve Daytime living area wall supply with grid Kitchen ceiling return with valve and ISO CORASE fat fume filter Daytime living area wall supply with grid Recirculation box with grid Recovery unit Dehumidification system integrated with the HRV system (no need for several dedicated systems) High efficiency and simple management (integrated systems optimise performance and reduce consumption) High dehumidification capacity for...

Open the catalog to page 14
FITT Agix - HRV Components - 15

LAYOUT DIAGRAM • surface 100sqm • 3 bedrooms, 2 bathrooms, living room, kitchen • 150-300m3/h recovery unit with dehumidification • recovery unit and distribution box installed in a technical compartment • wall mounted delivery ports • ceiling mounted suction vents • Ø75mm hose • ceiling mounted recirculation vents Delivery flow Return flow MATERIALS NEEDED FOR THE INSTALLATION OF THE SYSTEM

Open the catalog to page 15
FITT Agix - HRV Components - 16

fitt agix® cross: Centralised HRV with heat recovery GRAPHICS Mandata in camera a parete con griglia Mandata in zona studio a parete con griglia Ripresa in bagno a soffitto con valvola Mandata in zona giorno a parete con griglia Ripresa in cucina a soffitto con valvola e filtro ISO COARSE per fumi grassi Mandata in zona giorno a parete con griglia Maximum silence High continuous air exchange capacity System that can be perfectly integrated into living environments Integrated, customisable and remotely manageable configurations FITT AGIX

Open the catalog to page 16
FITT Agix - HRV Components - 17

LAYOUT DIAGRAM • surface 100sqm • 3 bedrooms, 2 bathrooms, living room, kitchen • 220 m3/h recovery unit • recovery unit and distribution box installed in a technical compartment • wall mounted delivery ports • ceiling mounted suction vents • Ø75mm hose Delivery flow Return flow MATERIALS NEEDED FOR THE INSTALLATION OF THE SYSTEM

Open the catalog to page 17

All FITT Spa catalogs and technical brochures

  1. FITT REVIX

    4 Pages

  2. FITT FLAT HD

    1 Pages

  3. FITT EVAPOOL

    1 Pages

  4. FITT PROFY

    1 Pages

  5. FITT BRAVO

    1 Pages

  6. FITT ALIFLEX

    2 Pages

  7. FITT ENOFLEX

    1 Pages

  8. FITT DIAMOND

    2 Pages

  9. FITT OILFLEX

    1 Pages

  10. FITT PURE

    2 Pages

  11. FITT Bluforce

    32 Pages